Philio Remote PSR03 Manual
- June 8, 2024
- Philio
Table of Contents
- Philio
- Remote
- SKU: PSR03
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 10: Auto Report Battery Time
- Parameter 2: Basic SetLevel
- Parameter 7: Customer Function
- Parameter 82: AssociationGroup 2Basic SetLevel
- Parameter 83: AssociationGroup 3Basic SetLevel
- Parameter 84: AssociationGroup 4Basic SetLevel
- Parameter 85: AssociationGroup 5Basic SetLevel
- Parameter 86: AssociationGroup 6Basic SetLevel
- Parameter 87: AssociationGroup 7Basic SetLevel
- Parameter 88: AssociationGroup 8Basic SetLevel
- Parameter 89: AssociationGroup 9Basic SetLevel
- Technical Data
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Philio
Remote
SKU: PSR03
Quickstart
This is a ****
Remote Control (Audio)
for
CEPT (Europe).
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
1. Have Z-Wave TMController entered add mode.2. Hold down the central key,
then press the top-right key three times within 1.5 seconds to enter the add
mode.3. After add successful, the device will wake to receive the setting
command from Z-WaveController about 20 seconds.
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The Remote PSR03 is a simple control can control AV device through Z-Wave-to- IR extender, and it can also controls 8 lighting groups ON/OFF via basic set, based on Z-Wavetechnology.It is a Z-Wave plus product, it supports the security, OTA… Those newest features of theZ-Wavetechnology.Z-Wave is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Hold down the central key, then press the top- right key four times within 1.5 seconds and do not release the top-right key in the 4 thpressed, and the LED will light ON.2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the keys. If successful, the LED will light ON one second. Otherwise, the LED will flash once.3. IDs are remove and all settings will reset to factory default.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
1. Have Z-Wave TMController entered add mode.2. Hold down the central key, then press the top-right key three times within 1.5 seconds to enter the add mode.3. After add successful, the device will wake to receive the setting command from Z-WaveController about 20 seconds.
Exclusion
1. Have Z-Wave Controller entered remove mode.2. Hold down the central key, then press the top-right key three times within 1.5 seconds to enter the remove mode.Node ID has been excluded.
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the Wake Up Notification messagetothenetwork,andwake-up10secondsforreceivethe setting commands. The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes. If the user want to wake-up the device immediately, please press the button once. The device will wake-up 10 seconds.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 4 | Z-Wave Plus Lifeline |
---|---|---|
2 | 4 | Lighting group 1 |
3 | 4 | Lighting group 2 |
4 | 4 | Lighting group 3 |
5 | 4 | Lighting group 4 |
6 | 4 | Lighting group 5 |
7 | 4 | Lighting group 6 |
8 | 4 | Lighting group 7 |
9 | 4 | Lighting group 8 |
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 10: Auto Report Battery Time
The interval time for auto report the battery level. 0 means turn off auto
report battery. The default value is 12.The value is in minutes.
Size: 1 Byte, Default Value: 12
SettingDescription
0 – 127 | The interval time for auto report thebattery level. |
---|
Parameter 2: Basic SetLevel
Setting the BASIC command value to turn on the light. The 0xFF(-1) means
turn on the light. For dimmer equipment 1 to 100 means the light strength. 0
means turn off the light.
Size: 1 Byte, Default Value: -1
SettingDescription
0 | Turn off the light |
---|---|
1 – 99 | Set the light to level 1-99, 99 is full brightness |
-1 | -1 (0xFF) means turn the light on |
Parameter 7: Customer Function
Customer function switch, using bit control.Bit0: Switch AV control/Lighting
group control. (0: AV control, 1: lighting group control)
Size: 1 Byte, Default Value: 0
SettingDescription
0 | AV Control |
---|---|
1 | Lighting Group Control |
Parameter 82: AssociationGroup 2Basic SetLevel
Setting the BASIC command value to turn on the light in the association
group 2. 0 means using the value of configuration 2 to set.
Size: 1 Byte, Default Value: 0
SettingDescription
1 – 99| Setting the BASIC command value to turn on the light in the
association group 2.
---|---
0| Use the value set by configuration parameter 2.
-1| BASIC Command On (0xFF)
Parameter 83: AssociationGroup 3Basic SetLevel
Setting the BASIC command value to turn onthe light in the association group
3. 0 means using the value of configuration 2 toset.
Size: 1 Byte, Default Value: 0
SettingDescription
1 – 99| Setting the BASIC command value to turn on the light in the
association group 3.
---|---
0| Use the value set by configuration parameter 2.
-1| BASIC Command On (0xFF)
Parameter 84: AssociationGroup 4Basic SetLevel
Setting the BASIC command value to turn on the light in the association
group 4. 0 means using the value of configuration 2 to set.
Size: 1 Byte, Default Value: 0
SettingDescription
1 – 99| Setting the BASIC command value to turn on the light in the
association group 4.
---|---
0| Use the value set by configuration parameter 2.
-1| BASIC Command On (0xFF)
Parameter 85: AssociationGroup 5Basic SetLevel
Setting the BASIC command value to turn on the light in the association
group 5. 0 means using the value of configuration 2 to set.
Size: 1 Byte, Default Value: 0
SettingDescription
1 – 99| Setting the BASIC command value to turn on the light in the
association group 5.
---|---
0| Use the value set by configuration parameter 2.
-1| BASIC Command On (0xFF)
Parameter 86: AssociationGroup 6Basic SetLevel
Setting the BASIC command value to turn on the light in the association
group 6. 0 means using the value of configuration 2 to set.
Size: 1 Byte, Default Value: 0
SettingDescription
1 – 99| Setting the BASIC command value to turn on the light in the
association group 6.
---|---
0| Use the value set by configuration parameter 2.
-1| BASIC Command On (0xFF)
Parameter 87: AssociationGroup 7Basic SetLevel
Setting the BASIC command value to turn on the light in the association
group 7. 0 means using the value of configuration 2 to set.
Size: 1 Byte, Default Value: 0
SettingDescription
1 – 99| Setting the BASIC command value to turn on the light in the
association group 7.
---|---
0| Use the value set by configuration parameter 2.
-1| BASIC Command On (0xFF)
Parameter 88: AssociationGroup 8Basic SetLevel
Setting the BASIC command value to turn on the light in the association
group 8. 0 means using the value of configuration 2 to set.
Size: 1 Byte, Default Value: 0
SettingDescription
1 – 99| Setting the BASIC command value to turn on the light in the
association group 8.
---|---
0| Use the value set by configuration parameter 2.
-1| BASIC Command On (0xFF)
Parameter 89: AssociationGroup 9Basic SetLevel
Setting the BASIC command value to turn on the light in the association
group 9. 0 means using the value of configuration 2 to set.
Size: 1 Byte, Default Value: 0
SettingDescription
1 – 99| Setting the BASIC command value to turn on the light in the
association group 9.
---|---
0| Use the value set by configuration parameter 2.
-1| BASIC Command On (0xFF)
Technical Data
Hardware Platform | SD3502 |
---|---|
Device Type | Remote Control – AV |
Network Operation | Portable Slave |
Firmware Version | 01 |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-14110010 |
Z-Wave Product Id | 0x013C.0x0008.0x001D |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Controlled Command Classes
- Basic
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>