AIRCARE AWM10AWHT Aria Humidifier User Manual

June 5, 2024
AIRCARE

AWM10AWHT Aria Humidifier
User Manual

Everything you need to know about your
ARIA
ALL AWM10AWHT MODELS
Read and save these instructions

IMPORTANT SAFETY INSTRUCTIONS – READ BEFORE USING YOUR HUMIDIFIER
WARNING: To reduce the risk of fire, electric shock, or injury, always unplug the unit before moving, filling, servicing, or cleaning. Do not pour or spill water onto the controls or motor area. If these get wet, let them dry completely and have the unit checked by authorized service personnel before plugging in. Do not use the humidifier if any parts are damaged or missing. Contact us for replacement parts at 800.547.3888.

  1. To reduce the risk of fire or shock hazards, this humidifier has a polarized plug (one blade is wider than the other). Before using, inspect the power cord to verify it is not damaged. If the cord is damaged, do not use the unit. Plug humidifier directly into a 120V, A.C. electrical outlet. Do not use extension cords. If the plug does not fully fit into the outlet, reverse the plug. If it still does not fit contact a qualified electrician to install the proper outlet. Do not change the plugin anyway.
  2. Keep the electric cord out of traffic areas. To reduce the risk of fire hazards, never put the electric cord under rugs, near heat registers, radiators, stoves, or heaters.
  3. Do not attempt to repair or modify the electrical or mechanical functions of this appliance, as doing so may void your warranty.
  4. This appliance emits steam which can cause bums. Do not place the unit closer than four feet from the bedside, or within 6 inches of the wall. Do not allow the unit to be used as a toy. Close attention is necessary when used by or near children.
  5. Keep the humidifier clean. To reduce the risk of injury, fire, or damage to humidifiers, use only cleaning fluids specifically recommended for humidifiers. Never use flammable, combustible, or poisonous materials to clean your humidifier.
  6. Do not place metals, chemicals, or detergents into the water tank. Do not put foreign objects inside the humidifier.
  7. This unit has a heating element located in the base. Always test for heat before handling the base.
  8. To reduce the risk of accidental electrical shock, do not touch the cord or controls with wet hands.
  9. To reduce the risk of fire, do not use near an open flame such as a candle or other flame source.
  10. Only add clean, cool water to the water talk. Do not add medication or aroma/ essential oils to the water tank. Only add oils into the oil/medicine cup. Do not add water directly to the water basin (bottom section). Do not allow water to pour or splash onto the base to avoid damage to internal parts. Do not operate the unit in a room with temperatures below freezing.
  11. Do not operate the unit with an empty water tank.
  12. If the unit emits an abnormal sound or odor, shut it down and unplug it immediately.

HUMIDIFIER ONE-YEAR LIMITED WARRANTY POLICY
SALES RECEIPT REQUIRED AS PROOF OF PURCHASE FOR ALL WARRANTY CLAIMS
This warranty is extended only to the original purchaser of this humidifier when the unit is installed and used under normal conditions against defects in workmanship and materials as follows:

  • One (1)year from the date of sale on the unit, and
  • Thirty (30)days on wicks and filters, which are considered a disposable components and should be replaced periodically.

The manufacturer will replace the defective part/product, at its discretion, with return freight paid by the manufacturer. It is agreed that such replacement is the exclusive remedy available from the manufacturer and that TO THE MAXIMUM EXTENT PERMITTED BY LAW, THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGE OR LOSS OF PROFITS OR REVENUES. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
Warranty Exclusions: We are not responsible for the replacement of wicks and filters. We are not responsible for any incidental or consequential damage from any malfunction, accident, misuse, alterations, unauthorized repairs, or abuse, including failure to perform reasonable maintenance, normal wear and tear, nor where the connected voltage is more than 5% above the nameplate voltage. We are not responsible for any damage from the use of water softeners or treatments, chemicals, or d.caling materials. We are not responsible for the cost of service calls to diagnose the cause of trouble, or labor charge to repair and or replace parts. No employ., agent, dealer, or other person is authorized to give any warranties or conditions on behalf of the manufacturer. The customer shall be responsible for all labor costs incurred. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
Obtaining Warranty Service: Within the limitations of this warranty, purchasers with inoperative units should contact customer service at 800.5473888 for instructions on how to obtain service within the warranty as listed above. This warranty gives the customer specific legal rights, and you may also have other rights which vary from province to province, or state to state. Register your product at www.aircareproducts.com.

LET’S GET YOU UP AND RUNNING

  1. Remove the Aria from its packaging.
    You should have: a. Base
    b. Lid

    1B73300

    c. Water bottle

    1B73301

    d. Water bottle cap

    1B73302

    e. Cooling chamber

    1B73303

    f.Inner tray

    1B73304

    g. Four rubber feet

    1B73305

    h. Owner’s manual

    1B73374

    If you are missing any parts, or need replacement parts, call us at 800.547.3888or visit our website aircareproducts.com.
    HEART, We hope you love your Aria.
    Prefer to see a video?
    Watch the Aria set-up at aircareproducts.com/support.
    SCAN THE CODE TO THE RIGHT WITH YOUR PHONE’S CAMERA CAMERA
    https://AIRCAREProducts.com/support
    AIRCARE AWM10AWHT Aria Humidifier - figure 1

  2. Your Aria is fully assembled and needs no additional set-up.

  3. Put your Aria on a level surface in the room where steam humidity is most needed. To avoid condensation, make sure the unit is at least two inches from the wall and not under a window.
    Note: The Aria emits hot steam, so be careful to avoid contact, and keep children away from the unit. Also, position the unit to direct this steam away from furnishings and electronics.

  4. Remove the lid and take out the water bottle. Fill the bottle, then screw the cap back on. Your Aria holds .75 gallons of water.
    About water additives:
    • Do not add essential oils to the Aria water bottle.
    • Do not use water softeners.

  5. If you are using medicinal inhalants, like menthol liquid, or essential oils, add these to the round medicine cup on top of the cooling chamber. Never add these directly to the water bottle.

  6. Replace the lid, then plug in your unit and press the power button. The Aria’s power light glows green when the power is on.
    Note: The power light will glow red when the Aria is out of the water and steam output will stop until you refill the humidifier.
    That’s it! Your Aria is ready to use.

HOW TO CLEAN YOUR ARIA

Regular cleaning is important for preventing mold, mildew, and other bacterial growth in your humidifier. It also keeps your Aria working its best.

  1. Turn off the Aria and wait 15 minutes for the base to cool.
  2. Take off the lid and remove everything from the base.
  3. Pour out any remaining water from the bottle and base.
  4. Fill the water bottle half-full with water and 1 1/2 cups of white vinegar. Swish the water-vinegar mixture vigorously around the bottle. Let this sit for 20 minutes. To disinfect, replace the vinegar with ½ teaspoon of bleach. Do not mix vinegar and bleach.
  5. Fill the base half-full with undiluted white vinegar. Let it sit for 20 minutes. If you’re disinfecting, please skip this step and proceed to step 6.
  6. After 20 minutes, empty the bottle and base (if using the vinegar method).
  7. Dampen a sponge with white vinegar and wipe down the base interior and all of the components. Rinse everything thoroughly. To disinfect, replace the vinegar with bleach.
  8. Wipe everything dry and reassemble.

When storing your Aria, disinfect the unit using the directions above. Dry the unit thoroughly, and store it in a temperature-regulated area.

FREQUENTLY ASKED QUESTIONS

Q. Where is my serial number?| A. Your serial number is on the sticker on the bottom of
your unit. You can write it here for future reference:
---|---
Q. Why is my unit putting out very little steam?| A. • Check that your Aria is on a level surface.
• Make sure your humidifier is full of water.
• Filtered and distilled water can produce less steam.
Try switching to another water type.
• Adding one or two pinches of salt can help the healing process.
Q. What is Aria’s stream temperature?| A. The Aria is manufactured to reach 160 degrees.
Household temperatures can sometimes affect this.
Q. Why is the power light red?| A. Your Aria is out of water.
Q. Can I add essential oils to the medicine cup?| A. Yes, the medicine cup can be used for medicated inhalants (like menthol liquid) or essential oils.
Q. Can I add medicinal inhalants directly to the water tank?| A. No, this will damage your Aria.
Q. Can I order replacement parts?| A. Yes! Your Aria’s parts and their part numbers are listed on page 2.

For any other questions or issues, contact our humidifier experts!
They are ready by phone, email, or chat.

phone 800.547.3888
 [email protected]
 aircareproducts.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AIRCARE User Manuals

Related Manuals