AIRCARE AUV10AWHT AURORAmini Ultrasonic Cool Mist Humidifier Instruction Manual
- June 5, 2024
- AIRCARE
Table of Contents
- AIRCARE AUV10AWHT AURORAmini Ultrasonic Cool Mist Humidifier
- IMPORTANT SAFETY INSTRUCTIONS- READ BEFORE USING YOUR HUMIDIFIER
- HUMIDIFIER ONE-YEAR LIMITED WARRANTY POLICY
- LET’S GET YOU UP AND RUNNING
- HOW TO CLEAN YOUR AURORAmini
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AIRCARE AUV10AWHT AURORAmini Ultrasonic Cool Mist Humidifier
IMPORTANT SAFETY INSTRUCTIONS- READ BEFORE USING YOUR HUMIDIFIER
WARNING: To reduce the risk of fire, electric shock, or injury, always unplug the unit before moving, filling, servicing, or cleaning. Do not pour or spill water onto the controls or motor area. If these get wet, let them ry completely and have unit checked by authorized service personnel before plugging in. Do not use the humidifier if any parts are damaged or missing. Contact us for replacement parts at 800.547.3888.
- To educe the risk of fire or shock, this humidifier has a polarlized plug. Plug the humidifier directly into a 120V, AC electrical outlet. Do not use extension cords. If the plug does not fully fit into your outlet, contact a ualified electrician to install the proper outlet. Do not alter the plug in any way
- Keep the electric cord out of traffic areas. To reduce the risk of fire hazard, never put the electric cord under rugs, or near heat registers, radiators, stoves, or heaters.
- Keep the humidifier clean. To reduce the risk of injury, fire, or damage to humidifier, use only cleaning fluids specifically recommended for humidifiers. Never use flammable, combustible, or poisonous materials to clean your humidifier.
- Do not place metals, chemicals, or detergents into the water tank. Do not put foreign objects inside the humidifier.
- To reduce the risk of electrical hazard or damage to humidifier, do not tit, jolt, tip, or carry the humidifier while unit is running.
- Never touch the nebulizer upon starting.It will cause you pain.
- Do not allow unit to be used as a toy. Close attention is necessary when used by or near children.
- To reduce the risk of damage and fire, do not use near a hot air source (like a radiator, hot air duct, etc.) or an open flame.
- To reduce the risk of accidental ellectrical shock, do not touch the cord or controls with wet hands.
- Only add clean, cool water to water tank. Do not add medication or aromalessential oil to the water tank. Only add oils to the diffuser tray.
- Do not add water directly to the water basin (bottom section). To avoid damage to intemal parts, do not allow water to pour or splash onto base. Do not operate unit in a room with temperatures below freezing
- Do not operate unit with an empty water tank.
- If the unit emits an abnormal sound or odor, shut it down and unplug it immediately
HUMIDIFIER ONE-YEAR LIMITED WARRANTY POLICY
SALES RECEIPT REQUIRED AS PROOF OF PURCHASE FOR ALL WARRANTY CLAIMS
This warranty is extended only to the original purchaser of this humidifier
when the unit is installed and used under normal conditions against defects in
workmanship and materials as follows:
One (1) year from date of sale on the unit, and Thirty (30) days on wicks and
filters, which are considered disposable components and should be replaced
periodically.
The manufacturer will replace the defective part product, at its discretion,
with return freight paid by the manufacturer. It is agreed that such
replacement is the exclusive remedy available from the manufacturer and that
TO THE MAXIMUM EXTENT PERMITTED BY LAW, THE MANUFACTURER IS NOT RESPONSIBLE
FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGE OR LOSs
OF PROFITS OR REVENUES.
Some states do not allow limitations on how long an implied warranty lasts, so
the above limitations may not apply to you.
Warranty Exclusions: We are not responsible for the replacement of wicks and
filters. We are not responsible for any incidental or consequential damage
from any malfunction, accident, misuse, alterations, unauthorized epairs,
abuse, including failure to perform reasonable maintenance, normal wear and
tear, nor here the connected voltage is more than 5% above the nameplate
voltage. We are not responsible for any damage from the se of water softeners
or treatments, chemicals or descaling materials. We are not responsible for
the cost of service calls to diagnose the cause of trouble or labor charge to
repair and/or replace parts. No employee, get, dealer or other person is
authorized to give any warranties or conditions on behalf of the manufacturer.
The customer shall be responsible for all labor costs incurred. Some states do
not allow the exclusion or Imitation of incidental or consequential damages,
so the above limitations or exclusions may not apply to you. Obtaining
Warranty Service: Within the limitations of this warranty, purchasers with
inoperative units should contact customer service at 800.547.3888 for
instructions on how to obtain service within the warranty as listed above.
This warranty gives the customer specific legal rights, and you may also have
other rights which ary from province to province, or state to state. Register
your product at www.aircareproducts.com.
LET’S GET YOU UP AND RUNNING
-
Remove the AURORAmini from its packaging. You should have:
-
Base
-
Water tank: #1B73183
-
Nozzle: #AMUVN
-
Water tank cap: #AUCAP
-
Essential oil tray: #AMUTRAY
-
Essential oil pads: #AURP10PK
-
Owner’s manual: #1B73384
If you are missing any parts, or need replacement parts, call us at 800.547.3888 or visit our website aircareproducts.com.
HEART We hope you love your AURORAmini.
Prefer to see a video? Watch the AURORAmini set-up at aircareproducts.com/support.
SCAN THE CODE TO THE RIGHT WITH YOUR PHONE’S CAMERA -
Fill the water tank, then screw the cap back on, making sure the cap is correctly threaded. Your AURORAmini holds .33 gallons of water.
About water additives:
- Do not add essential oils directly to the AURORAmini water tank. Only add them to the essential oil tray.
- Do not use water softeners.
-
Put the water tank on the base with the AIRCARE logo over the control knob, then put the top nozzle on the tank.
-
Put your AURORAmini on a level surface in the room where humidity is most needed. To avoid condensation, make sure the unit is at least two inches from the wall and not under a window.
Note: The AURORAmini is an ultrasonic humidifier, so it emits a very fine mist. Position the nozzle to direct this mist away from furnishings and electronics. -
To add essential oils, remove the essential oil tray from the side of the AURORAmini base. Add a few drops of essential oil to the tray pad. Add more oil to your liking. Only use essential oils in the tray; any brand will work with the AURORAmini.
-
Plugin your unit and turn the control knob to the right to turn on the AURORAmini. The power light will glow green. Set your desired mist output level by turning the knob to the right (higher) and left (lower).
Note: For your first use, run your AURORAmini at full output until the unit is empty. The power light will glow red when the AURORAmini is out of water and mist output will stop until you refill the humidifier. The nightlight will continue to glow even when the AURORAmini is empty. -
Select the nightlight color by pressing the LED button on the front of the AURORAmini.
- first press: the colors rotate
- second press: holds the current color
- third press: purple
- fourth press: blue
- fifth press: teal
- sixth press: green
- seventh press: yellow
- eighth press: orange
- ninth press: red
- tenth press: nightlight off
That’s it! Your AURORAmini is ready to use.
HOW TO CLEAN YOUR AURORAmini
Regular cleaning is important for preventing mold, mildew, and other bacterial growth in your humidifier. It also keeps your AURORAmini working its best.
- Let the unit run until it’s empty, then turn it off.
- Remove the water tank and unscrew the cap. Pour out any remaining water from the tank.
- Fill the tank a little more than half-full with water and add 2 tablespoons of white vinegar. Pour a little of this vinegar-water mixture into the base.
- Put the water cap back on, shake the tank gently, then let sit for 20 minutes.
- With the mixture in the base, use a soft cloth to clean the inside of the base. Gently scrub the oscillator (the dark ring in the basin). Let sit for 20 minutes.
- After 20 minutes, empty the water tank and base.
- Dampen a sponge with white vinegar and wipe down the base, tank, tank nozzle, and cap. Rinse everything thoroughly.
- Wipe everything dry and reassemble.
When storing your AURORAmini, clean the unit as described above. Dry the unit thoroughly, and store in a temperature-regulated area. Do not install a new demineralization cartridge until you are ready to use your humidifier again.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>