PROSCEND 810G-5PI Industrial GbE Unmanaged PoE Switch Installation Guide

June 9, 2024
PROSCEND

PROSCEND 810G-5PI Industrial GbE Unmanaged PoE Switch

Connecting Power

The 810G-5PI can be powered by two ways, one is directly connected to 4-pin DC IN power-connector, the other way is to insert the positive and negative wires (AWG 14-26) into V+ and V- contact on the terminal block respectively and tighten the wire-clamp screws to prevent the wires from being loosened. The input rage is 48~55 VDC.

4-pin DC IN power-connector

DC Terminal Block

Alarm Rely and Ground

  • The alarm relay output contacts are in the middle of the DC terminal block connector as shown in the figure below.
  • The alarm relay out is “Normal Open”, and it will be closed when either one of PWR1 or PWR2 is not connected to power supply.
  • The relay output with current carrying capacity of 0.25A @ 50 VDC.
  • The switch must be properly grounded for optimum system performance.

PROSCEND-810G-5PI-Industrial-GbE-Unmanaged-PoE-Switch-
fig-4

PWR1 PWR2 DC IN Relay Alarm
Detected Detected N/A Open Off
Not Detected Detected N/A Close On
Detected Not Detected N/A Close On
Not Detected Not Detected N/A Close On

LED Indicators

PROSCEND-810G-5PI-Industrial-GbE-Unmanaged-PoE-Switch-
fig-9

RJ45 Connector Pinouts

The pin assignment of RJ45 connector is shown in the following table.

Pin Description PoE Pinouts
1,2 T/Rx+, T/Rx- V+
3,6 T/Rx+, T/Rx- V−
4,5 T/Rx+, T/Rx- X
7,8 T/Rx+, T/Rx- X

DIN-rail Mounting

  • STEP 1: Use the screws to install the DIN-rail kit to attach at the rear side of the switch.

PROSCEND-810G-5PI-Industrial-GbE-Unmanaged-PoE-Switch-
fig-6

  • STEP 2: Hook the unit onto the DIN-rail.
  • STEP 3: Push the bottom of the unit towards the DIN-rail until it locks in place.

PROSCEND-810G-5PI-Industrial-GbE-Unmanaged-PoE-Switch-
fig-7

NOTE