AIRCARE OWM220AWHT Steam Humidifier Instruction Manual

June 5, 2024
AIRCARE

AIRCARE OWM220AWHT Steam Humidifier

IMPORTANT SAFETY INSTRUCTIONS READ BEFORE USING YOUR HUMIDIFIER

WARNING

To reduce the risk of fire, electric shock, or injury, always unplug the unit before moving, filling, servicing, or cleaning. Do not pour or spill water onto the controls or motor area. if these get wet, let them dry completely and have the unit checked by authorized service personnel before plugging in. Do not use the humidifier if any parts are damaged or missing. Contact us for Tor replacement parts at 800.54/.3888.

  1. To reduce the risk of fire or shock hazards, this humidifier has a polarized plug (one blade is wider than the other) Before using, inspect the power cord to verify it is not damaged. if the cord is damaged, do not use the unit. Plug humidifier directly into a 120V, A.C. electrical outlet. Do not use extension cords. If the plug does not fully fit into the outlet, reverse the plug. If it still does not i, contact a qualified electrician to install the proper Outlet. Do not change the plugin anyway.

  2. Keep the electric cord out of traffic areas. To reduce the risk of fire hazards, never put the electric cord under rugs, near heat registers, radiators,or eaters.

  3. Do not attempt to repair or modify the electrical or mechanical functions of this appliance, as doing so may void your warranty.

  4. This appliance emits steam which can cause burns. Do not place the unit closer than four feet from the bedside, or within 6 inches of the wall. Do not allow the unit to be used as Close attention is nerecsan hen or hr and DEI, O ones o Wall. Do not

  5. Keep the humidifier clean. To reduce the risk of injury, fire, or damage to the humidifier, use only deaning fluids specifically recommended for
    humidifiers. Never use Flammable, Combustible, or poisonous materials to clean your humidifier

  6. Do not place metals, chemicals, or detergents into the water tank.

  7. Do not put foreign objects inside the humidifier if the unit has an element located in the base. Always test tor heat before handling the base.

  8. to reduce the risk of accidental electrical shock, do not touch the cord or controls with wet hands.

  9. to reduce the risk of fire, do not use near an open flame such as a candle or other Tlame source.

  10. Only add dean and cool water to the water tank. Do not add medication or aroma/ essential oils to the water tank. Only add oils into the oil/medicine cup.

  11. Do not add water directly to water basin (Dotom section). Do not allow water to pour or splash onto Dase to avoid damage to internal Paris.

  12. If the unit emits an abnormal come or Odor, shut it down and unplug it immediately.

HUMIDIFIER ONE-YEAR LIMITED WARRANTY POLICY

SALES RECEIPT REQUIRED AS PROOF OF PURCHASE FOR ALL WARRANTY CLAIMS

This warranty 5 extended only to the original purchaser of this humidifier when the unit s installed and used under normal conditions against Defects in workmanship and material as follow:

  • one year date of sale on the unit, and
  • Thirty (0)days on wrecks and Tilters, which are considered disposable components and should be replaced periodically.

The manufacturer will replaces the detective part product, at its discretion, with return freight paid by the manufacturer. ts agreed that such Sereneavelabe Ron te manufacturer anna EMAIL EXPERT BrAMANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGE OR LOSS OF PRO HIS OR REVENUES. Some states do not allow limitations on how long an implied warranty lasts, s0 the above limitations may not apply to you.

warranty Exclusions.

we are not responsible for the replacement of is and Titers. we are not responsible for any incidental or consequential Damage from any malfunction, accident, misuse, alteration, unauthorized repairs, or abuse, including failure to perform reasonable maintenance, normal wear, and tear, nor where the connected voltage is more than 5% above the nameplate voltage. We are not responsible for any damagefrom the use of water softeners or treatments, chemicals, or descaling materials. we are not responsible for the cost of service calls to diagnose the cause of trouble, or labor charge to repair and/or replace parts. No employee, agent, dealer, or other person is authorized to give any warranties or conditions on behalf of the manufacturer. The customer shall be responsible for all labor costs incurred. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.

Obtaining Warranty Service

Within the limitations of this warranty, purchasers with inoperative units should contact customer service at 800.547.3888 for instructions on how to obtain service within the warranty as listed above. This warranty gives the customer specific legal rights, and you may also have other rights which vary from province to province, or state to state. Register your product at www.aircareproducts.com.

LET’S GET YOU UP AND RUNNING

Remove the Ozark from its packaging you should have:

  • Base
  • Water tank and lid
    • 1B73263

  • Interlock (attached to the base)
    • 1B73264

  • Owner’s manual
    • 1B73381

  1. Put your Ozark on a level surface in the room where steam humidity is most needed. To avoid condensation, make sure the unit is at least two inches from the wall and not
    under a window.

Note: The Ozark emits hot steam, so be careful to avoid contact, and keep children away from the unit. Also, position the unit to direct this steam away from furnishings and electronics.

  1. Remove the lid and fill the water tank. The water tank lifts out, so you can also take it to the sink to fill it.
  2. The handle is just to lift the water tank for filling, so do not use it to carry the Ozark while it is full. Your Ozark holds 1 gallon of water.
  3. If you are using medicinal inhalants, like menthol liquid, add it to the medicine cup where indicated by the medicine iconon the front of the Ozark. Only use medicine in this cup, and never add these to the water tank.
  4. Plugin your unit and turn the control knob to the right to turn on the Ozark. The power light around the knob will glow green and your unit will be on the low setting. Turning the knob to the right again sets your output to high.

Note: The power light will glow red when the Ozark is out of the water and steam output will stop until you refill the humidifier. The nightlight will continue to glow even when the Ozark is empty. That’s it! Your Ozark is ready to use.

HOW TO CLEAN YOUR OZARK

Regular cleaning is important for preventing mold, mildew, and other bacterial growth in your humidifier. also keeps your Ozark working its best

  1. Turn off the Ozark, unplug it, and wait 15 minutes for the base to cool.
  2. Remove the tank and set it aside
  3. With the tank off, turn the base with the power cord toward you. Locate the steam tower lock it is attached with a small screw to the right of the tower.
  4. Slide the lock to the ight with your thumb. While holding the lock, remove the two pieces of the steam tower. Put these pleces in a small sink or waterproof container
  5. Fill the tank with water and 3 cups of white vinegar
  6. Pour half of this mixture into the sink or container with the two steam tower pieces and let them soak for 20 minutes.
  7. Pour a little more of the mixture into the base. Use a soft cloth to gently scrub the interior surfaces of the base. Let this sit tor 20 minutes.
  8. Swish the remaining water-vinegar mixture vigorously around the tank. Let this sit for 20 minutes.
  9. After 20 minutes, empty the tank and base and rinse both well with water. Remove the steam tower pieces from their Soak and rinse them well. Dry everything with a soft cloth, and reassemble.

TO DISINFECT YOUR OZARK

  1. Remove the tank and fill it with water and 1 teasp0on of bleach. Let it sit for 20 minutes, then rinse the base thorOughly.
  2. Dampen a soft cloth with the bleach-water mixture and wipe out the base.
  3. Use a clean, soft cloth to dry all of the parts, then reassemble.fig-6

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

AIRCARE User Manuals

Related Manuals