RenewAire SL75H Energy Recovery Ventilator Owner’s Manual
- July 8, 2024
- RenewAire
Table of Contents
RenewAire SL75H Energy Recovery Ventilator
SPECIFICATIONS
Ventilation Type:
Static plate, heat and humidity transfer
Typical Airflow Range: 30–130 CFM
Unit is HVI Tested/Certified per CSA C439 Protocol:
Using one L-30-G5 Core
Standard Features:
White painted cabinet
Line-cord power supply or hard wired to junction box (H)
Low-voltage circuit for controls
Unit may be mounted in any orientation
Cross-core differential pressure ports
Dial-A-Flow: balance and airflow adjustment
Variable speed
Boost-mode
Controls :
Onboard digital controller with independent variable speeds
Filters :
Total qty. 2, MERV 8, spun-polyester media: 7 1/2″ x 10 1/2″ x 1″
Unit Weight : 35 lbs.
Max. Shipping Dimensions & Weight (in carton):
31 1/4″ L x 22 3/8″ W x 14 3/8″ H
41 lbs.
Units Per Pallet: 10
Motor(s):
Qty. 2, 120V EC motorized impellers
Accessories:
Backdraft damper: 6″, 8″ Automatic balancing damper: 4″, 5″, 6″ Motorized
dampers: 6″, 8″ Concentric vent: 6″ (CV6-110) Louvered wall vent 6″: white,
brown Louvered wall vent 8″: taupe vinyl, galvanized, paintable galvanneal
Louvered wall vent with 8″ round duct connection: 12″ W x 8″ H Digital time
clock: wall mount (TC7D-W), in exterior enclosure (TC7D-E) Carbon dioxide
sensor/control: wall mount (CO2-W) IAQ sensor: wall mount (IAQ-W) Motion
occupancy sensor/control: ceiling mount (MC-C), wall mount (MC-W) Push-button
boost timer (PBT) Percentage timer control (PTL) Percentage timer control with
furnace interlock (FM) BACnet fan control: wall mount (BACNETFC-W) Push-button
point-of-use controls (PBL), PTL req’d. MERV 13 filter: OA airstream (shipped
loose) Wall bracket kit Electric duct heater: RH series (1–4 kW);designed for
indoor ductwork installation only
Note: There are multiple control options designed to address individual climate conditions. Please consult your local installer for the best installation controls for your climate
EC MOTOR OPERATING RANGE AND CORE PERFORMANCE
● = Actual tested sample points
┃ = Operating curves, airflow is held constant as static pressure varies
Factory settings
1. High speed set to top curve
2. Low speed set to ~90CFM at 0.4 in. w.g. ESP
**Airflow (CFM)**
|
External Static Pressure (Inches Water Column)
|
Unit Power Consumption (Watts)
|
**Sensible EFF%**
|
**Total EFF% Winter/Summer**
---|---|---|---|---
Max. Speed
138| 0.10| 135| 62| 54/36
131| 0.20| 134| 64| 55/38
125| 0.30| 133| 65| 57/40
117| 0.40| 132| 66| 59/42
110| 0.50| 131| 68| 60/44
102| 0.60| 129| 69| 62/46
95| 0.70| 126| 71| 64/48
87| 0.80| 123| 72| 66/51
78| 0.90| 119| 74| 68/53
68| 1.00| 114| 76| 70/56
49| 1.20| 102| 79| 75/61
21| 1.40| 64| 85| 81/69
Min. Speed
26| 0.10| 11| 84| 80/68
11| 0.20| 9| 87| 83/72
Notes :
- Watts is for the entire unit.
- Airflow performance includes effect of clean, standard filter supplied with unit.
- Refer to CORES for specific operating point electrical data.
- These are core-only ratings and are not HVI certified. Total EFF% calculated at 35/33wb OA and 70/58wb RA (winter) and 95/78wb OA and 75/63wb RA (summer). HVI ratings apply to complete units only. This unit is HVI certified. See HVI certified ratings on pg. 46 of Single/Multi-Family Catalog and at hvi.org.
Watts
|
Volts
|
Hz
|
Phase
|
FLA per motor
|
Minimum Circuit Amps
|
Max Overcurrent Protection Device
---|---|---|---|---|---|---
53| 120| 60| 1| 0.85| 15| 15
ABBREVIATIONS
EA: Exhaust Air to outside
OA : Outside Air intake
RA: Room Air to be exhausted
SA: Supply Air to inside
INSTALLATION ORIENTATION
Unit may be installed in any orientation.
NOTE
- UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE ROUNDED TO THE NEAREST EIGHTH OF AN INCH.
- SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE.
AIRFLOW ORIENTATION
Drawing Type: Unit Dimension
UNIT MOUNTING & APPLICATION
an be mounted in any orientation. RA/EA airstream can be switched with OA/SA airstream.