Haswill Electronics STC-8080H Digital Thermostat Microcomputer Temperature User Manual

June 11, 2024
HASWILL ELECTRONICS

Haswill logo

Haswill Electronics STC-8080H Digital Thermostat Microcomputer

Temperature

Haswill Electronics STC-8080H Digital Thermostat Microcomputer
Temperature

STC 8080H owns one sensor, two output relays to connect and control the refrigeration and the defrosting unit, by the preset aim temperature range 40 to 50°C) and the time setting, it offers an editable delay time before an over temperature alarm occurs.

Package

  • Controller: 1PCS
  • Fasteners: 2PCS
  • Sensor: 1PCS
  • Manual: 1PCS
  • Waterproof Cover: 1PCS

Specification

Input Power 220V AC ± 10% 50/60HZ; (12/24/48/110V Option)
Maximum current 10A (Default) under 220V AC
Sensor NTC, 25°C /10 KΩ, the sensor cable 200cm
Protection Class IP65 to the front panel
Storage -10°C ~ 60°C, RH<90%, without condensation
Measurable Range -50°C ~ +99°C
Controllable Range -40°C ~ +50°C
Resolution 1°C
Accuracy ± 1°C from -40°C to +50°C; ± 2°C in other range
Power Consumption ≤ 3W

Interface & Operation

Front Panel & Icon
Under normal status

  1. Hold the Set key for 3s to enter the setting mode;
  2. Hold the ⇓ key for 3s to start the forced defrosting mod; do it again to stop defrosting.
  3. Press the ⇑ to check the Upper limit F1F1, default 10 °C;
  4. Press the ⇓ to check the Lower limit F2F2, default 20 °C;
  5. Press the Set to check the Defrosting Cycle / Interval Time F 77, default 8 Hours;
  6. Press the Rst to check the defrosting lasting time F 88;
    The screen will back to normal status after 3s if without operation.

Haswill Electronics STC-8080H Digital Thermostat Microcomputer Temperature
1

Indicator / Character

Indicator Meaning On Hide Wink
Defr Defrosting status Working Stop N/A
Cool Compressor status Working Stop Delay
Set Setting Status Setting Normal N/A
Dimensions & Installation

Haswill Electronics STC-8080H Digital Thermostat Microcomputer Temperature
2

A. Suggested amount dimension: 712985+ mm (WHD)
B. Detach the slide fasteners, put the controller into the hole, wiring follow the diagram
C. Install the fasteners, and install the waterproof cover.
D. Please avoid installing in the below environments:

  • Relative humidity > 90%, have condensation
  • The places that temperature 10°C or >60°C;
  • The places that have inflammable and explosives;
  • Strong vibration or struck
  • Exposed to the continuous water mist spraying;
  • Exposed to the dust;
  • Exposure to corrosive and pollution gas (for example, the gas, smoke, or salt fog that contain sulfur or ammonia;
  • Wireless electromagnetic interference or strong magnetic fields (near to transmitting antenna or switch board room);
Wiring Diagram

Haswill Electronics STC-8080H Digital Thermostat Microcomputer Temperature
3

A. 10K NTC sensor, Need not to distinguish + or when wiring it.
B. The input voltage must within the marked voltage ±10%.
C. Suggest: Load Power ≤ The voltage of load ∗ Max current of Relay/ Factor

Configurations

Code and Function Menu

Code Function Min Max Default Unit
F1 Temperature for Refrigeration Starts F2 50 -10 °C
F2 Temperature for Refrigeration Stops -40 F1 -20 °C
F3 Temperature Calibration – 5 5 0 °C
F4 Compressor Delay Time 0 9 3 Min
F5 Over-temperature to Trigger Alarm (more than F1) 0 50 15 °C
F6 Alarm Delay Time 0 99 20 Min
F7 Defrosting Cycle / Interval Time 0 99 8 Hour
F8 Defrosting Lasting Time 0 99 20 Min

How to Correct Measured Temperature?
F3 = Real Temperature – Measured Temperature

How to Set Parameters?
Step1 Hold the Set key for 3s, and the code F1 will appear.
Step2 Press the UP or DOWN keys to get the aim function you want to update;
Step3 Press the Set key to check to exist value, Hold the Set key meanwhile press the or ∧ UP or DOWN ∨ key to change the value;
Step4 Release all keys once it reaches your aim value; Repeat operation from Step 2 / 3 / 4 to adjust other parameters;
Step5 Press the Rst key to save data and back to normal monitor status.
Attention the modified value will be saved automatically and back to normal status if without operation in 30 seconds.

When will the Compressor Start/Stop Work?
Two conditions to works

  1. The time should be later than the compressor last stops moment + 3 minutes (not editable),
  2. Room Temperature ≥ F1
    In other words,
    F1 is the upper limit to trigger refrigeration, and
    F2 is the lower limit to stop it.
    But if found sensor error, the compressor works 15mins then stops 30mins.

When will the Defrosting Start/Stop Work?
Firstly F7 ≠ 0 and F8 ≠ 0, and there are two defrosting modes:

A. Manual Forced-Defrosting:
Under refrigerating status, if a user holds the button for 3s, the defrosting begins at once; oppositely, this operation will stop the defrosting.
B. Automatically defrosting:
It will work according to the F7 and F8 values; time counts from the controller turn on the moment.

Error & Alarm

A. If F5 = 0, the alarm function was banned.
B. If F5 ≠ 0, the alarm will be triggered if it reaches both of below two conditions:

  • Pass the Alarm delay time (F6)
  • Instant temperature ≥ F1 + F5 or Instant temperature ≤ F2 – F5

The buzzer is screaming when an alarm occurs; meanwhile, the readout and error code alternate display. Press any key to stop it from screaming, but the error code will not disappear until all problems were fixed.

Code Reason Troubleshooting
E1 memory unit broken Press the SET key to restore the default data or

get the

factory reset

E2| Sensor error| Ensure the sensor was installed firmly or replace a new sensor. The alarm will disappear in 15s once the problem is fixed.
HH| 99°C < Instant temp.

< 120°C

| Check the room temperature, then change the compressor / defrosting device’s working status manually if necessary.

Environmental Information
The package’s material is 100% recyclable. Just dispose of it through specialized recyclers.
The electro components can be recycled if it is disassembled for specialized companies.
Please do not burn or throw the controllers in domestic garbage; observe the respective law in your region concerning the environmentally responsible manner of disposing of its devices.