CDVI K3 DESFire EV2 High-Security Keypad and Card Reader Installation Guide

June 5, 2024
CDVI

CDVI K3 DESFire EV2 High-Security Keypad and Card Reader Installation Guide
CDVI K3 DESFire EV2 High-Security Keypad and Card Reader Installation Guide

INTRODUCTION

K3
DESFire EV2® High-Security Keypad and card reader
Radio equipment for access control applications.

CDVI’s KRYPTO K3 card reader/keypad makes high security easy! KRYPTO K3 Mifare® DESFire® EV2® readers combined with CDVI EV2 credentials work right out of the box. No fastidious and complicated programming required!

Factory-programmed, industry-unique secure CDVI protocol and encryption keys ensure end-to-end encryption between the card, reader/keypad and A22K door controller.

FEATURES

  • Bi-technology, keypad and reader
  •  Easy to use & FULLY secure CDVI protocol using authentication with diversified keys.
  • Reads 13.56 MHz Mifare® Classic and DESFire EV2 credentials
  • OSDP-2 compatible
  • Bluetooth
  • Up to 4 in. (10cm) read range
  • Power requirements: 12VDC
  • Current consumption : 200mA
    FEATURES

MOUNTING

MOUNTING

WIRING DIAGRAM

K3 READER
EXIT READER OPTION (RS485 ONLY):
Each A22K controller supports the Input/Output reader, 2 readers per door. Connect the 2 readers in parallel (as shown below).

CAUTION
The dipswitch must be at the bottom near the motherboard: Set the position of the switch before powering the player, or unplug and plug the player if you change the dip switch to the exit mode.

The 2 players must be separated by a distance of 20 cm to avoid any interference.

It is recommended to use CAT5e/6 cable

Distance between the reader and the controller up to 1220m (AWG 22 cable) \
WIRING DIAGRAM

LED STATUS INDICATORS

Here are the LED status when connected to an A22K ATRIUM controller :

LED State Buzzer Description
Steady blue Standby (door se- cure)
Green 5 sec. Chirp beep Access granted
Red blinks Steady beep for 3 sec. Access denied
Flashing blue Reader compromised (lost its encryption key)
Blinks green every 3 sec. Door unlock schedule
Flashing Red Steady beep Door forced alarm
Flashing Red Beep every 2 sec. Door open too long pre-alarm
Flashing Red rapidly Fast beep Door open too long alarm

Note:

Door output timings such as; unlock time (access granted), door open too long pre-alarm and door open too long alarm, can be modified in the ATRIUM software “Door Properties” window.