CDVI i180ER 180Kg Mortice Electromagnetic lock Stainless Steel Installation Guide

June 12, 2024
CDVI

CDVI i180ER 180Kg Mortice Electromagnetic lock Stainless Steel

Product Information

  • Product Name: i180ER
  • Product Type: Mortice Electromagnetic Lock
  • Material: Stainless Steel
  • Lock Type: Monitored
  • Corrosion Resistance: High
  • Warranty: 10 years
  • Installation: Easy
  • Recommended Use: Exterior
  • Fail Mode: Fail safe (Door unlocked when power off)
  • Holding Force: 180 kg
  • Built-in Varistor: Yes (Built-in electronic protection to eliminate back EMF)
  • Dimensions (L x W x D): 201 x 32 x 24 mm
  • Armature Plate Dimensions (L x W x D): 130 x 32 x 9 mm
  • Power Supply: 12/24V dc
  • Consumption: 450 mA @ 12V dc, 225 mA @ 24V dc
  • IP Rating: IP66
  • Certifications: CE Certification, WEEE & RoHS Compliant

Product Usage Instructions

  1. Mounting Recommendations:
    • Securely fix the magnetic lock and armature plate to their supports.
    • Ensure that the magnetic lock and the armature plate are aligned.
    • Mount the armature plate floating around the central mounting screw to compensate for any misalignment of the door.
  2. Electrical Connections:
    • For default setup, use 12V dc power supply.
    • Check the jumper position before connecting the lock to the input current. Incorrect positioning can damage the lock.
    • The N.O./N.C. signal only switches when the door is closed with the electromagnetic lock powered.
    • Refer to the manual for voltage selection jumpers and terminal block connections.
    • Correspondence:
    • 12 or 24V dc – 0V
    • Normally closed (NC) – COM
    • Normally open (NO)

PRODUCT PRESENTATION

  • Monitored
  • Mortice
  • High corrosion resistance
  • Delivered with armature plate
  • No mechanical wear
  • Ease of installation
  • Recommended for exterior use
  • Fail safe (Door unlocked when power off) Holding force: 180 kg
  • Built-in varistor: Built-in electronic protection to eliminate back EMF
  • Dimensions (L x W x D): 201 x 32 x 24 mm
  • Armature plate dimensions (L x W x D): 130 x 32 x 9 mm
  • Power supply: 12/24V dc
  • Consumption: 450 mA @ 12V dc 225 mA @ 24V dc

PACKAGE CONTENT

CDVI i180ER 180Kg Mortice Electromagnetic lock Stainless Steel-
FIG2

ELECTRICAL CONNECTIONS

12V dc default setup

Terminal block| ****

Correspondence

---|---
+| 12 or 24V dc
| 0V
NC| Normally closed
C| COM
NO| Normally open

The N.O./N.C. signal only switches when the door is closed with the electromagnetic lock powered

IMPORTANT NOTE

Check the jumper position before connecting the lock to the input current. An incorrect positioning could damage the lock. This type of damage is not covered by the warranty.

Voltage selection jumpers

Recommended power supplies

MOUNTING RECOMMENDATIONS

Armature plate

  • It is vital that the magnetic lock and armature plate are securely fixed to their supports.
  • The magnetic lock and the armature plate must be aligned.
  • The armature plate must be mounted “floating” around the central mounting screw to compensate for any misalignment of the door

Important Note: It is important to follow the mounting recommendations and check the jumper position before connecting the lock to avoid any damage. Incorrect positioning can void the warranty.

Recommended Power Supplies:

  • ADC335
  • ADC612S

For more information and support, contact CDVI customer service at:

CDVI UK [UNITED KINGDOM IRELAND]
Phone: +44 (0)1628 531300
Website: www.cdvi.co.uk

CDVI NORDIC [SWEDEN – DENMARK NORWAY
FINLAND]

Phone: +46 (0)31 760 19 30
Website: www.cdvi.se

CDVI AMERICAS [CANADA – USA – LATAM]
Phone: +1 866 610 0102
Website: www.cdvi.ca

CDVI BENELUX [BELGIUM – NETHERLANDS
LUXEMBOURG]

Phone: +32 (0) 56 73 93 00
Website: www.cdvibenelux.com

CDVI SUISSE
Phone: +41 (0)21 882 18 41
Website: www.cdvi.ch

CDVI ITALIA
Phone: +39 0321 90 573
Fax: +39 0321 90 8018
Website: www.cdvi.it

CDVI TAIWAN
Phone: +886 (0)42471 2188
Website: www.cdvichina.cn

CDVI CHINA
Phone: +86 10 84606132/82
Website: www.cdvichina.cn

CDVI MAROC
Phone: +212 5 2248 0940
Website: www.cdvi.ma

CDVI POLSKA
Phone: +48 12 659 23 44
Website: www.cdvi.com.pl

CDVI GERMANY
Phone: +49 (0) 175 2932 901
Website: www.cdvi.de

CDVI Official Website:
Website: www.cdvi.com

www.cdvi.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals