CDVI SEL2641R433-RC Bluetooth Controlled Radio Receiver Instruction Manual
- June 4, 2024
- CDVI
Table of Contents
Instruction Manual
Introduction
RX CUBE – Bluetooth-controlled radio receiver
The receiver ERONE “Cube” is a superheterodyne radio receiver operating at
433,92 MHz in AM/ASK demodulation.
It is compatible with the full range of remote controls Erone that use the
Keeloq® Hopping code security protocol.
This receiver can be programmed only via Bluetooth using the set-up and
control that can be done only using the app: “RX Cube” on a Smartphone ( iOS
or Android ).
Power supply 12-24 Vac/dc autodetect.
The equipment is manufactured in compliance with the provisions of European
Directive 2014/30/EU, 2014/35/EU, 2014/53/EU, and the provisions of the
standard EN 62368-1.
Part-name | F-code | Description |
---|---|---|
SEL2641R433-RC | F1001000105 | RECEIVER CUBE BT 12/24V |
Technical Specifications
Receiver type…………………………….. Superheterodyne
Operating frequency ………………….. 433,92 MHz – AM/ASK
Input sensitivity …………………………. -103 dBm
Input load: ………………………………… 50 Ohm
Power supply: …………………………… 12 – 24 Vac/dc ( autodetect)
Consumption max:……………………… 78 mA @12Vac
Peak consumption ……………………… 500 mA at power up
Max switching power: ………………… 1 A @ 24V ( max 60 V)
Relay number: ………………………….. 1
Operating modes: ……………………… Pulse / Latch / Timed
Release time (Timed mode): ………. from 1 sec. to 23h.59m:59s
Contacts: …………………………………. C-NO-NC
Memory capacity: ……………………… 250 user codes
TX security code: ……………………….. KeeLoq® Hopping code
Max code combination number: ….. 264
Operating temperature: ……………… -20°/+65°C
Housing protection: ……………………. IP2X
Overall dimensions: …………………… 50 x 32 x 20 mm
Communication with w/mobile phone: … Bluetooth
Standard: ………………………………….. BLE 4.2
IO : Compatibility: ………………………. Android, iOS
Release Android: ………………………. 5.1 and next
Release iOS: …………………………….. 10 and next
Dimensions
Warnings
The receiver allocation is very important for the best operation of the
system. Place the receiver far from interference sources such as big magnetic
fields or radio emissions. The distance between the 2 receivers must be at
least 1,5 m.
– The equipment must be powered from a device that provides a safe extra low
voltage (SELV) type LPS ( Low Power Source);
– There must be a suitable disconnecting device to the current drawn by the
receiver (90 mA max @ 12Vdc).
Wiring
Compatible transmitters
Erone – S2TR2641E2-E4-E2M
Erone – SETR2641AM1, SETR2641AM2
Erone – S3TR2641T1-T2-T4
Erone – S4TR2641E1-E2-E4
Erone – SETR2641TM
Erone – S7TR2641E4
Erone – FKT2641E1 – FKTHS2641E1- TTH2641E1
Erone – S4TR2641E1-E2-E4
CDVI – GALEOR
Color LED | Description |
---|---|
Green | Power ON |
NO Bluetooth communication
Green-Orange blinking| Bluetooth communication in progress
Orange| Relay excited
The App “RX CUBE”
The setup of the receiver can be done only through the App “Rx Cube”. So, first of all, download the App from “Apple Store” or “Google Play”. You can find it both by typing the name of the App, “RX Cube”, or searching simply CDVI and then selecting Rx Cube. Once downloaded, authorize the App to use Bluetooth communication. The App will ask even the GPS localization: please authorize it for the full operating of the Bluetooth BLE.
Start the App and press the scan button: the App begins scanning the
surroundings searching for any Rx Cube running in the range of the Bluetooth
signal ( 10 — 30 m ). much depends on the fixing position of the receiver and
whether the communication is direct or passes through walls. At the end of the
scanning, the screen will show all the receiver’s Rx Cube found.
The receiver, by the factory, comes with the name “CUBE”. If you power two or
more receivers simultaneously, the scanning will list many receivers all
identical: it is advisable to power one device at a time and possibly renames
it individually. The name of the device can have up to 12 characters.
7.0 Changing the factory name of the receiver
Type the default password 11111 (for administrator), Click UNLOCK, and enter into the main menu| Select Settings| Type the new name, give OK, then discon- next and make a new scanning.| The App will display the new name of the receivers
7.1 Password
The access to the receiver has 2 different security levels: ADMINISTRATOR and
INSTALLER.
Factory password for ADMINISTRATOR = 11111.
Factory password for INSTALLER = 00000
Both can make all the settings. Only the Administrator can change the
passwords, the Installer is not authorized
Memory
Enter the submenu Memory to manage the receiver memory: add or delete transmitters individually, add or delete a batch of transmitters, delete all the transmitters, and restore the memory to factory settings
8.1 Memorizing transmitters
8.1.1 Individually ( fig. 3)
The memorization can be done directly, pressing the button of the transmitter
to store or specifying its S/N and Facility code. In this case, you must
specify the button/s authorized ( you can store up to 4 buttons).
8.1.2 In one block ( fig. 4)
Specify the number of transmitters of the block, the detail of the first
transmitter ( S/N and Facility code ), and the buttons to enable ( A, B, C, or
D).
NOTE: The button Format allows to display of the numbers in DECIMAL or
HEXADECIMAL format
8.2 Delete transmitters
8.2.1 Individually
Enter the S/N and Facility code of the transmitter to delete and press DELETE
8.2.2 In one block
Specify the number of transmitters of the block, enter the S/N and Facility
code of the first TX and press DELETE
8.2.3 Delete memory
Press DELETE to delete all the transmitters memorized
8.2.4 Factory Default
This option allows for the deletion of all the transmitters and resets the
settings to the factory defaults: pulse mode, time of the timed mode ( 5
sec.), and name of the receiver ( CUBE).
Settings
Clicking on Settings it is possible to set the relay operating mode: PULSE, STEP, TIMED. In pulse mode, the relay remains activated for the entire duration of the radio transmission with a min. time of 300 mS. For the Timed mode, it is possible to set the release time of the relay from 1 sec. to 23h : 59m : 59s
Password
The password can be changed by selecting the icon Password on the mail screen.
Only the ADMINISTRATOR is authorized to change the password.
The password set-in-factory are:
• Administrator: 11111
• Installer: 00000
The password is composed of max 5 numeric digits (min 1)
A red message appears if the password is still the factory password.
NOTE: The icon PASSWORD, in the main menu, is RED when at least one of
the two passwords is still at the factory value
Info
The icon INFO of the main screen allows displaying the features of the
receiver: number of TX memorized, revision of the Firmware, and release of the
App.
It is possible to list the transmitters memorized: press
List. > The screen displays only 5-6 lines of the list. Scroll the list
by tapping the center of the screen.
The Serial number of the transmitters can be displayed in Decimal or
Hexadecimal format.
If you select one line, you display the information of a specific transmitter.
For each transmitter, it is displayed the FC + S/N and the button active ( A,
B, C, or D).
For changing this setting, press one of the 4 buttons and push CHANGE.
From this screen is also possible to DELETE the TX from the memory.
Command
It is possible to activate directly the relay from the App.
Enter the icon “Command” and press the button.
The symbol becomes RED confirming the relay activation.
CDVI AMERICAS
[CANADA – USA – LATIN AMERICA] www.cdvi.ca
CDVI BENELUX
[BELGIUM – NETHERLAND – LUXEMBOURG]
www.cdvibenelux.com
CDVI FRANCE
www.cdvi.com
CDVI UK
[UNITED KINGDOM – IRELAND – SOUTH AFRICA]
www.cdvi.co.uk
CDVI WIRELESS
www.erone.com
All the information contained within this document (pictures, drawings,
features, specifications, and dimensions) could be perceptibly different and
can be changed without prior notice. Reference manual:
CDVI_CUBE_IM_01_EN_A4_CMYK.pdf – Printed in Italy – Apr 2021
www.erone.com
Manufactured by: CDVI Wireless SPA
Via Piave, 23 – 31020 S.Pietro di Feletto (TV) – Italy
Tel: +39-0438-450860 – mail: info@erone.com –
web:www.erone.com
References
- CDVI Group
- Access Control Solutions Manufacturer - CDVI Americas
- Fabricant de solutions de contrôle d'accès - CDVI Suisse
- Access Control Solutions Manufacturer - CDVI UK
- Home - CDVI Group
- Producent rozwiązań z zakresu kontroli dostępu - CDVI Polska
- Produttore di soluzioni per il controllo degli accessi - CDVI Italia
- cdvi.ma
- Innovativa accesslösningar för alla branscher | CDVI® - CDVI Nordic AB
- Fabrikant van toegangscontrole-oplossingen - CDVI Benelux
- Fabricante de soluciones de control de acceso - CDVI Ibérica
- Fabbricanti di soluzioni per le automazioni- CDVI Wireless | Erone
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>