USER’S GUIDE
SOR SERIES
HIGH-END CONVECTOR
THE REPLACEMENT COMPONENT LIST INCLUDED
WARNING
Before installing and operating this product, the user and/or installer must
read, understand and follow these instructions and keep them handy for future
reference. If these instructions are not followed, the warranty will be
considered null and void and the manufacturer deems no further responsibility
for this product.
This product must be installed by a qualified person and connected by a
certified electrician, according to the electrical and building codes
effective in your region.
The following instructions must be adhered to in order to avoid personal harm
or property damages, serious injuries and potentially fatal electric shocks.
Protect the heating unit with the appropriate circuit breaker or fuse, in
accordance with the nameplate.
Make sure the line voltage (volt) is consistent with that indicated on the
unit’s nameplate.
This unit must be grounded.
Switch off the power at the circuit breaker/fuse before installing, repairing
and cleaning the unit.
Make sure the unit is appropriate for the intended use (if needed, refer to
the product catalog or a representative).
RECOMMENDED HEATING CAPACITY: 1.25 W/cubic foot (0.03 m³)
It corresponds to 10 W/square foot (0.09 m²) based on a standard ceiling
height of 8 feet (2.44 m). The recommended capacity is usually sufficient for
normal heating needs. Please note that the insulation quality of walls and
windows are some of the factors that influence heat losses, which modify the
required capacity to heat a room. If needed, refer to a specialist who will be
able to calculate these heat losses and optimize the required capacity or
consult the “Online heating calculation” section of the Stelpro website
(residential buildings). To heat a large room and to increase your comfort, it
is recommended to install several units instead of one. For example, 2 X 1000
W rather than 1 X 2000 W.
Do not install the unit where objects or pieces of furniture could be heat
damaged.
If the unit’s capacity is insufficient for the size of the room, it will be in
operation continuously and may become defective earlier and turn yellow.
Respect distances and positions indicated in the installation section.
If the installer or user modifies the unit, they will be held responsible for
any damage resulting from this modification, and the CSA certification could
be void.
This unit must not come into contact with a water source and must be protected
from splashes (e.g. a wet mop). Do not use it if any part has been immersed.
Moreover, do not turn it on or off when standing in water or if your hands are
wet.
When mounting the unit, make sure that the anchorage used can support the
total weight of the unit with the mounting brackets.
When cutting or drilling into a wall, do not damage electrical wiring and
other hidden utilities.
When starting up the unit for the first time or after a long period, it is
normal that it produces some temporary odours and whitish smoke.
Because this unit is hot when in use, it may pose risks even in normal
operation. Therefore, be careful and responsible when using it. To avoid
burns, do not let bare skin touch hot surfaces. Let the unit cool down for a
few minutes before handling it (it stays warm for some time after shut-down).
The bottom of this unit must be installed at least 4 inches (10.2 cm) from any
adjacent surfaces, and 4 inches (10.2 cm) from the floor. However, make sure
objects or pieces of furniture such as, but not limited to, blankets, towels,
beds, laundry baskets, clothing, papers, etc. do not come into contact with
the unit and keep them at least 12 inches (30.5 cm) from the unit since they
are more flammable than walls and floors. Failure to comply with this warning
could lead to a fire. Some materials are more heat-sensitive than others, so
make sure those near the unit can withstand heat.
Do not install on a wall behind a door.
Never block the air vents. This obstruction could lead to overheating, which
could result in a fire.
Do not insert or allow foreign objects to enter any air vent as this may cause
electric shocks, a fire or damages to the unit.
This unit has hot and arcing or sparking parts inside. It is not designed to
be used or stored in wet areas or areas containing flammable liquids,
combustible materials or corrosive, abrasive, chemical, explosive and
flammable substances such as, but not limited to, gasoline, paint, chlorine,
sawdust and cleaning products.
Some areas are dustier than others. Thus, it is the user’s responsibility to
evaluate if the unit must be cleaned based on the amount of dirt accumulated
on and inside air vents. Accumulated dirt can lead to a component malfunction
or give a yellowish colour to the unit. Failure to install and maintain the
unit in accordance with these instructions poses a fire hasard.
Thermal protection activation indicates that the unit has been subjected to
abnormal operating conditions. If the thermal protection remains activated or
activates and deactivates repeatedly, it is recommended that a qualified
electrician or a certified repair centre examine the unit in order to make
sure it is not damaged. (Refer to the limited warranty.) If the unit is
damaged or defective, cut off the power supply at the circuit breaker and call
a certified repair centre. (Refer to the limited warranty)
Note: When a part of the product specification must be changed to improve
operability or other functions, priority is given to the product specification
itself. In such instances, the instruction manual may not entirely match all
the functions of the actual product. Therefore, the actual product and
packaging, as well as the name and illustration, may differ from the manual.
The screen/LCD display shown as an example in this manual may be different
from the actual screen/LCD display. This unit must be used with the provided
thermostat.
SPECIFICATIONS
MODEL | WATTS | VOLTS | LENGTH MM IN. | KG | LB |
---|
HIGH MODELS – HEIGHT: 708 mm (27 7/8 in.)
SORH1002| 1000/750| 240/208| 457| 18| 6.8| 15.1
SORH1502| 1500/1125| 240/208| 623| 24 1/2| 8.8| 19.4
SORH2002| 2000/1500| 240/208| 768| 30 1/4| 10.5| 23.2
LOW MODELS – HEIGHT: 330 mm (13 in.)
SORL1002| 1000/750| 240/208| 750| 29 1/2| 5.2| 11.5
SORL1502| 1500/1125| 240/208| 1113| 38 7/8| 6.9| 15.1
SORL2002| 2000/1500| 240/208| 1276| 50 1/4| 8.3| 18.3
STANDARD MODELS – HEIGHT: 455 mm (17 7/8 in.)
SOR0502| 500/375| 240/208| 457| 18| 4.8| 10.7
SOR1002| 1000/750| 240/208| 597| 23 1/2| 6| 13.2
SOR1502| 1500/1125| 240/208| 743| 29 1/4| 7.2| 15.9
SOR2002| 2000/1500| 240/208| 895| 35 1/4| 9.7| 21.4
Add W for white or SW for soft white
BUILT-IN THERMOSTAT TECHNICAL SPECIFICATIONS
DISPLAYED TEMPERATURE RANGE| 0 °C TO 50 °C (32 °F TO 122 °F)
TEMPERATURE DISPLAY RESOLUTION| 0.5 °C (1 °F)
SETPOINT RANGE| 5 °C TO 30 °C (41 °F TO 86 °F)
SETPOINT INCREMENTS| 0.5 °C (1 °F)
STORAGE TEMPERATURE RANGE| -50 °C TO 50 °C (-58 °F TO 122 °F)
OPERATING TEMPERATURE*| -20 °C TO 50 °C (-4 °F TO 122 °F)
TECHNICAL DRAWINGS
**** INSTALLATION
INSTALLATION OF WALL RACK
- Release the unit from the wall rack by depressing the hooks.
- Place the wall rack on the floor and against the wall where the unit is to be installed.
- Using a pencil and the holes provided in the wall rack, make marks on both sides of the rack at the desired height for the bottom of the wall rack. Although not mandatory, please note that the positioning of the unit makes installation easier with the use of the pre-cut holes.
- Securely fasten the rack to the wall, making sure that it is level. When drilling into the wall, make sure not to damage any electrical wiring or other hidden objects.
N.B. The wall where you install this rack must be straight so that the bracket remains flat once installed without having to apply any pressure. If the rack is not flat once installed, the hooking mechanism could be compromised and the convector could unexpectedly release from its rack.
THE BOTTOM OF THIS UNIT MUST BE INSTALLED AT LEAST 4 INCHES (10.2 CM) FROM THE FLOOR.
INSTALLATION OF CONVECTOR ON WALL RACK
- Insert the lower hooks of the wall bracket into the lower slots on the rear of the convector.
- Engage the hooks of the wall rack into the upper slots on the rear of the convector.
- Push on the convector to make sure that it is fully engaged with the wall rack. You should hear the hooks engage when pressure is applied to the upper front of the convector.
ELECTRIC WIRING
The supply wires must be connected in accordance with all effective building
and electrical codes. The bare (ground) wire must be connected to the green
wire in the convector using an appropriate wire nut. The supply wires (from
the electrical panel) must be connected to the wires labeled “L1” and “L2” in
the convector using appropriate wire nuts.
N.B. This product must be connected by a qualified electrician as per the
wiring diagram to the right and in accordance with building and electrical
codes effective in your area.
OPERATION
BUILT-IN ELECTRONIC THERMOSTAT FOR SMART HOMES (ST218)
ADJUSTING THE TEMPERATURE SETPOINT
– By pressing either button on the thermostat, the temperature setpoint will
be displayed as flashing digits.
– The temperature setpoint is set by using the UP ( ) or DOWN ( ) buttons to
raise or lower the setpoint respectively by increments of 0.5 °C (1 °F) each
time the buttons are pressed. Holding down either button will allow you to
scroll more quickly to the desired temperature setpoint.
– Once the desired setpoint has been selected, release the button. This
setpoint will remain in memory for the current mode (COMFORT or ECO (
**ECO)**
– see next section for details). The display will stop flashing
after 3 seconds and will then display the ambient temperature in the room.
– In order to sensitize the user about energy consumption, the color of the
contour around the buttons will change according to the setpoint selected;
green being a lower setpoint and red being a higher setpoint.
NOTE #1: In OFF mode, the setpoint displayed is ( — ) and the ( ) icon is
displayed indicating that there is a potential risk of freezing. In this mode,
it is not possible to modify the setpoint. If a new setpoint is sent from the
smart home controller while the convector is in OFF mode, the thermostat will
return to COMFORT mode.
NOTE #2: The setpoint in ECO mode is local to the convector. In other
words, its setpoint cannot be set by the smart home controller. If a new
setpoint is sent via the smart home controller while the convector is in ECO
(**ECO**
) mode, the thermostat will return to COMFORT mode.
NOTE #3: If a setpoint change is sent by the smart home controller, the
display will flash this setpoint on the thermostat for 3 seconds and then
return to normal.
SELECTING THE OPERATION MODE
There are three (3) operation modes: COMFORT mode, ECO mode (identified by the
(**ECO**
) icon) and OFF mode (identified by the ( ) icon). To switch from
one mode to another, simply press and then release both buttons simultaneously
NOTE #1: If the operation mode is changed remotely by the smart home
controller, the setpoint (or ( — ) when in OFF mode) will be displayed for 3
seconds and will then return to normal.
NOTE #2: Once the ECO mode has been selected, the convector will respect
the ECO mode setpoint for the duration as configured (see ECO MODE DURATION
section for details). Once the duration for ECO mode has elapsed (unless OFF
is selected), the convector will automatically return to COMFORT mode.
THERMOSTAT DISPLAY
– Ambient room temperature (or the setpoint when flashing)
– Operation mode: COMFORT, ECO (**ECO**
), OFF ( )
– The ( ) icon indicates a freezing risk either due to a low setpoint or if
the thermostat is set to OFF. This icon will flash if an open window is
detected.
– The thermostat displays the percentage of heating time required to maintain
the desired temperature.
– The status of the connectivity with the ZigBee ( ) network.
– The ( ) is displayed when the controls are locked. See LOCKING THE CONTROLS
for details.
BUTTON FUNCTIONS
BUTTONS | DISPLAY | ADVANCED MENUS |
---|---|---|
SINGLE BUTTON | ADJUSTMENT OF TEMPERATURE SETPOINT | NAVIGATION AND EDITING OF |
PARAMETERS
BOTH BUTTONS SIMULTANEOUSLY| MODE SELECTION (COMFORT, ECO, OFF)| SELECTION AND
CONFIRMATION OF PARAMETERS
BOTH BUTTONS HELD SIMULTANEOUSLY FOR 3 SECONDS| ACCESS TO ADVANCED MENUS| EXIT
FROM ADVANCED MENUS
ZIGBEE CONNECTIVITY
This convector is compatible with the ZigBee smart home protocol. Once
connected, it can be controlled remotely by means of the application included
with the user’s ZigBee controller.
FOLLOW THESE STEPS TO CONNECT YOUR CONVECTOR TO A ZIGBEE NETWORK:
– Make sure that the ZigBee controller is in ASSOCIATION mode
– Access the advanced menus
– Select menu 1 ( )
– If ON is selected, the convector will find the channel assigned to the
ZigBee network. You can also manually specify the channel that your ZigBee
controller is currently using. The ZigBee connection process will be faster if
the ZigBee channel is manually specified.
– During the association, your selection will flash rapidly and the
connectivity icon ( ) will be animated
– Once the association with the ZigBee network has been established, the
channel number will be shown on the display
– If an error occurs during association, (ERR) will be displayed for 3 seconds
followed by (OFF) being displayed
FOLLOW THESE STEPS TO DISCONNECT YOUR CONVECTOR FROM THE ZIGBEE NETWORK:
– Access the advanced menus
– Select menu 1 ( )
– Change the parameter to (OFF)
– During the disassociation, (OFF) will flash rapidly and the connectivity
icon ( ) will be animated
– Once the disassociation with the ZigBee network has been completed, (OFF)
will be displayed
– If an error occurs during disassociation, (ERR) will be displayed for 3
seconds followed by the channel number being displayed
TEMPERATURE FORMAT
The temperature can be displayed in either degrees Celsius or Fahrenheit.
Follow these steps to select the temperature format:
– Access the advanced menus
– Select menu 2
– Select either °C or °F
DISPLAY BACKLIGHTING
Both the display backlighting as well as the lighted control buttons can be
configured. When either button is pressed, the buttons are lit with a color
(see ADJUSTING THE TEMPERATURE SETPOINT for details of colors displayed) and
the display will be at 100% brightness. If no button is pressed for 15
seconds, the display can behave in one of three ways:
- ALL: The display backlighting is active but dimmed. The button contours remain colored
- BTN: The backlighting is off. The button contours remain colored.
- OFF: The backlighting is off. The button contours are colored light gray Follow these steps to configure the backlighting and button behavior:
− Access the advanced menus
− Select menu 3 ( )
− Select ALL, BTN or OFF
NOTE: The display backlighting and the button contours will be at 100% intensity if a problem is detected with the ZigBee communication or if a window is open.
LOCKING THE CONTROLS
This mode allows you to lock the controls in order to prevent unwanted changes
to the setpoint and/or operation modes. While the ( ) icon is displayed, only
changes sent by the ZigBee controller are possible.
NOTE: The advanced menus remain accessible at all times. Follow these
steps to activate or deactivate the control lock:
– Access the advanced menus
– Select menu 4 ( )
– Select (ON) or (OFF)
OPEN WINDOW DETECTION
This convector can detect an open window in the room and lower the setpoint so
as not to waste energy.
When the convector detects an open window in the room, the ( ) icon will flash
and the button contours will flash in blue. The setpoint will be automatically
set to 7 °C (45 °F). Once the convector detects that the window has been
closed, the setpoint will return to its previous setting.
Follow these steps to activate or deactivate the open window detection:
– Access the advanced menus
– Select menu 5 ( )
– Select (ON) or (OFF)
ECO MODE DURATION
By default, the ECO (**ECO**
) mode duration is set to (OFF). In other
words, the mode selection is permanent and the convector will remain in ECO
mode unless another mode is manually selected or selected remotely by the
smart home controller.
Follow these steps to modify the duration of the ECO **(ECO)**
mode:
– Access the advanced menus
– Select menu 6 (**ECO**
)
– Select the duration from the values available ranging from:
– 1-12 hrs, in one-hour increments
– 14 hrs
– 16 hrs
– 18 hrs
– 1-7 days, in one-day increments
°STELPRO MENU
Information about the convector is available in this menu. It is also possible
to reset the convector to its factory settings (menu 7.7).
Follow these steps to access this information:
– Access the advanced menus
– Select menu 7
– Select one of the following sub-menus:
– 7.1: Version of convector
– 7.2: Version of ZigBee ‘radio’
– 7.3: Day manufactured
– 7.4: Month manufactured
– 7.5: Year manufactured
– 7.6: Internal control code
– 7.7: Factory reset of convector
FREEZE PROTECTION
The ( ) icon will be displayed when the thermostat is adjusted between 5 °C
(41 °F) and 7 °C (45 °F) and indicates that the ambient room temperature will
not drop below the freezing point.
OFF MODE (OFF)
See the SELECTING THE OPERATION MODE section for the procedure to activate the
OFF mode.
NOTE #1 : There is still voltage present in the convector and there is a
risk of electric shock even if the OFF mode is activated. Always switch the
circuit breaker off prior to servicing or cleaning the convector.
NOTE #2 : The convector will NEVER heat when in OFF mode. A freeze risk
is present when the OFF mode is activated.
FACTORY RESET
Follow these steps to reset the convector to its factory settings:
– Access the advanced menus
– Select menu 7
– Select sub-menu 7.7. Confirm selection when (def) is displayed
– Select (yes) and confirm the selection
– (yes) will blink for few seconds and the convector will be reset to its
factory settings
BUTTON CONTOUR COLOURS
BUTTON CONTOUR COLORS | CONVECTOR CONDITION |
---|---|
GREEN | NORMAL OPERATION, ECONOMICAL TEMPERATURE SETPOINT |
BETWEEN GREEN AND RED
| IN NORMAL OPERATION, THE COLOR REFLECTS HOW ECONOMICAL THE TEMPERATURE
SETPOINT IS; MORE GREEN IS MORE ECONOMICAL, AND REDDER IS LESS ECONOMICAL.
RED| NORMAL OPERATION, HIGH-TEMPERATURE SETPOINT
BLUE| CONVECTOR IN OFF MODE
FLASHING BLUE| OPEN WINDOW DETECTED
WHITE| WHILE IN ADVANCED MENUS
GRAY| WHEN THE BACKLIGHTING IS SET TO OFF AND THE BUTTONS REMAIN INACTIVE FOR
MORE THAN 15 SECONDS
MAINTENANCE
N.B. In order for the warranty on this product to remain valid, it must be
cleaned on a regular basis.
Always cut off the power at the breaker or fuse prior to cleaning the unit.
Use a soft rag to dust the unit or a damp cloth to clean it. In order to
prevent yellowing and/or damage to the product finish, do not use cleaning
products (chemical or abrasive). Regularly use a vacuum brush to remove dust
and any other foreign objects from the grill if the product is installed in a
very dusty area.
NOTE: Cigarette smoke can accelerate the yellowing of the discharge
grill. More frequent cleanings are recommended in these conditions.
N.B. High voltage and the risk of electric shock are present in the unit even
if the thermostat is set to OFF.
STAINLESS STEEL CLEANING TIPS
Although stainless steel is corrosion resistant, its finish can still be
damaged. It is recommended to clean the stainless steel surfaces on a regular
basis and not to wait until a full cleaning is necessary. Since the acidity
level and chlorine content of regular cleaning agents vary greatly, it is
highly recommended to thoroughly rinse the surface with clean water following
their use. Stainless steel polishes can also be used and are recommended.
Always polish the stainless steel surfaces with the grain and never against
the grain.
DO NOT USE
– chlorine or chlorine-based cleaners
– scrubbing pads or other scrubbing devices (steel wool)
– abrasive cleaning agents
– hydrochloric acid-based products such as bleach: can stain and/or damage
stainless steel surfaces
TROUBLESHOOTING
PROBLEM | DEFECTIVE PART OR PART TO CHECK |
---|---|
The unit does not work | – Defective thermostat |
– Open circuit breaker or fuse
– Thermal protection activated
– Faulty connections
The unit runs continuously| – Defective wall-mounted thermostat
– Heat losses greater than the unit capacity
The housing is extremely hot| – Defective thermal protection
– Blocked air vents
The desired room temperature cannot be reached
| – One or more defective elements
– Defective wall-mounted thermostat
– Voltage lower than indicated on the nameplate
– Heat losses greater than the unit capacity
Overheating| – Defective wall-mounted thermostat
– Setpoint is set too high
The unit cycles under the control of the thermal protection (overheat
indicator)| – Blocked air vents
The heater is on and the breaker trips| – Faulty connections
– Voltage higher than that indicated on the nameplate
The unit does not heat| – One or more elements in the unit are defective
– Defective temperature probe
– Temperature setpoint set too low
– OFF mode activated
– Open window detected
– Defective wall thermostat
The connectivity icon ( ) is flashing on the display| – There is a problem
with the ZigBee ‘radio’. Reinitialize the convector.
The temperature setpoint and/or the operation mode cannot be modified| – The
unit is locked. Deactivate the control lock ( )
N.B. If you do not solve the problem after checking these points, cut off the power supply at the main electrical panel and contact our customer service (please refer to the Limited Warranty to obtain the phone numbers)
ERROR CODE | DEFINITION |
---|---|
LO | A temperature lower than 0 °C (32 °F), the unit will always heat unless |
set to OFF
HI| Temperature higher than 50 °C (122 °F), the unit will never heat
—| – If displayed in place of the temperature setpoint: OFF mode activated,
heating not possible
– If displayed in place of the ambient temperature: defective temperature
probe, heating not possible. Call customer service for assistance.
Err| The connection to the ZigBee network has failed. Ensure that the unit is
within range of the ZigBee controller and that it is in ASSOCIATION mode.
E1| Defective auxiliary temperature probe. The unit will still control the
temperature, but the performance of the thermostat may be diminished. Call
customer service for assistance.
REPLACEMENT COMPONENT LIST
MODEL| HOUSING| FRONT PANEL| WALL SUPPORT| THERMAL PROTECTION (AUTO.)| ELEMENT
(TYPE X)| THERMOSTAT CONTROL| THERMOSTAT POWER SUPPLY
---|---|---|---|---|---|---|---
| 1| 2| 3| 4| 5| 6| 7
SOR0502| M-SOR0500A| M-SOR0500B| M-SOR0500C0| PROT-005-1| ELF-SOR0201X|
ST-218| CIR-044
SOR1002| M-SOR1000A| M-SOR1000B| M-SOR1000C0| PROT-007-1| ELF-SOR0501X
SOR1502| M-SOR1500A| M-SOR1500B| M-SOR1500C0| ELF-SOR0701X
SOR2002| M-SOR2000A| M-SOR2000B| M-SOR2000C0| ELF-SOR1001X
SORH1002| M-SORH1000A| M-SORH1000B| M-SORH1000C0| ELF-SORH0501X
SORH1502| M-SORH1500A| M-SORH1500B| M-SORH1500C0| ELF-SORH0701X
SORH2002| M-SORH2000A| M-SORH2000B| M-SORH2000C0| ELF-SORH1001X
SORL1002| M-SORL1000A| M-SORL1000B| M-SORL1000C0| ELF-SORL1002X
SORL1502| M-SORL1500A| M-SORL1500B| M-SORL1500C0| ELF-SORL1502X
SORL2002| M-SORL2000A| M-SORL2000B| M-SORL2000C0| ELF-SORL2002X
- Add W for white or SW for soft white
NOTE: LOW MODEL has only one element
LIMITED WARRANTY
This limited warranty is offered by Stelpro Design inc. (“Stelpro”) and
applies to the following product made by Stelpro: SOR model. Please read this
limited warranty carefully. Subject to the terms of this warranty, Stelpro
warrants its products and their components against defects in workmanship
and/or materials for the following periods from the date of purchase: 5 years
(3 years on electronic components). This warranty applies only to the original
purchaser; it is non-transferable and cannot be extended.
CLAIM PROCEDURE
If at any time during the warranty period the unit becomes defective, you must
cut off the power supply at the main electrical panel and contact 1) your
installer or distributor, 2) your service center or 3) Stelpro’s customer
service department. In all cases, you must have a copy of the invoice and
provide the information written on the product nameplate. Stelpro reserves the
right to examine or to ask one of its representatives to examine the product
itself or any part of it before honoring the warranty. Stelpro reserves the
right to replace the entire unit, refund its purchase price or repair a
defective part. Please note that repairs made within the warranty period must
be authorized in advance in writing by Stelpro and carried out by persons
authorized by Stelpro.
Before returning a product to Stelpro, you must have a Stelpro authorization
number (RMA). To obtain it, call the customer service department at:
1-800-363-3414 (electricians and
distributors – French), 1-800-343-1022
(electricians and distributors – English), or
1-866-766-6020 (consumers). The
authorization number must be clearly written on the parcel or it will be
refused.
CONDITIONS, EXCLUSIONS AND DISCLAIMER OF LIABILITY
This warranty is exclusive and in lieu of all other representations and
warranties (except of title), expressed or implied, and Stelpro expressly
disclaims and excludes any implied warranty of merchantability or implied
warranty of fitness for a particular purpose.
Stelpro’s liability with respect to products is limited as provided above.
Stelpro shall not be subject to any other obligations or liabilities
whatsoever, whether based on contract, tort or other theories of law, with
respect to goods or services furnished by it, or any undertakings, acts or
omissions relating thereto. Without limiting the generality of the foregoing,
Stelpro expressly disclaims any liability for property or personal injury
damages, penalties, special or punitive damages, damages for lost profits,
loss of use of equipment, cost of capital, cost of substitute products,
facilities or services, shutdowns, slowdowns, or for other types of economic
loss or for claims of a dealer’s customers or any third party for such
damages. Stelpro specifically disclaims all consequential, incidental, and
contingent damages whatsoever.
This warranty does not cover any damages or failures resulting from 1) a
faulty installation or improper storage; 2) an abusive or abnormal use, lack
of maintenance, improper maintenance (other than that prescribed by Stelpro)
or use other than that for which the unit was designed; 3) a natural disaster
or an event out of Stelpro’s control, including, but not limited to,
hurricanes, tornadoes, earthquakes, terrorist attacks, wars, overvoltage,
flooding, water damages, etc. This warranty does not cover any accidental or
intentional losses or damages, nor does it cover damages caused by the
negligence of the user or owner of the product. Moreover, it does not cover
the cost of disconnection, transport, and installation.
The warranty is limited to the repair or the replacement of the unit or the
refund of its purchase price, at the discretion of Stelpro. Any parts replaced
or repaired within the warranty period with the written authorization of
Stelpro will be warranted for the remainder of the original warranty period.
This warranty will be considered null and void and Stelpro will have the right
to refuse any claims if products have been altered without the written
authorization of Stelpro and if the nameplate numbers have been removed or
modified. This warranty does not cover scratches, dents, corrosion or
discoloration caused by excessive heat, chemical cleaning products and
abrasive agents. It does not cover any damage that occurred during the
shipping. Some states and provinces do not allow the exclusion or limitation
of incidental or consequential damages and some of them do not allow
limitations on how long an implied warranty lasts, so these exclusions or
limitations may not apply to you. This warranty gives you specific legal
rights and you may have other rights which vary from state to state or from
province to province.
STELPRO | Saint-Bruno-de-Montarville | Quebec | J3V 6L7
For further information or to consult this guide online,
please visit our website at www.stelpro.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>