Product Information

Product Name V5SR 500 kg Surface Mount Electromagnetic Lock
Manufacturing Year 1985
Features
  • Monitored

  • Surface mount

  • High corrosion resistance

  • Safety rope

  • No mechanical wear

  • No residual magnetism

  • Ease of installation

  • Recommended for interior use

  • Fail safe (Door unlocked when power off)

  • Holding force: 500 kg

  • Visual indication (Blue = Locked ; Green = Open)

  • Built-in varistor: built-in electronic protection to eliminate
    back EMF

  • Dimensions (L x W x D): 272 x 66 x 40 mm

  • Armature plate dimensions (L x W x D): 185 x 60 x 12 mm

  • Power supply: 12-24V dc

  • Consumption: 290 mA @ 12V dc, 145 mA @ 24V dc

  • IP42

  • WEEE & RoHS

  • CE Certification

  • UKCA Certification

Package Content|

  • Wood screw
  • Magnetic lock
  • Armature plate
  • Roll pin
  • Cap nut
  • Fixing plate
  • Security rope
  • M8 Screw
  • Steel washer
  • Rubber washer
  • MOUNTING RECOMMENDATIONS

Electrical Connections|

  • Voltage: 12V dc (Default setup)
  • Terminal Description:
    • + : Power supply positive terminal
    • N.C : Normally closed terminal
    • COM : Common terminal
    • N.O : Normally open terminal

Product Usage Instructions

Mounting Recommendations

To properly mount the electromagnetic lock, follow these steps:

  1. Attach the magnetic lock and armature plate securely to their supports.
  2. Ensure the magnetic lock and the armature plate are aligned.
  3. Mount the armature plate floating around the central mounting screw to compensate for any door misalignment.

Electrical Connections

When connecting the lock to the input current, make sure to:

  • Check the jumper position before connecting the lock to avoid
    damaging it. Incorrect jumper position can void the warranty.

  • Ensure the magnet and the armature meet evenly over their entire facing surfaces.

  • Allow the armature plate to pivot slightly about its center mounting screw to compensate for any door misalignment.

Recommended Power Supplies

Voltage Recommended Power Supply
12V ADC335, ADC612S
24V ADC324, PSMB242

Security Rope Installation

To ensure the safety of users and prevent the electromagnetic lock from detaching, follow the steps below:

  1. Install the two safety ropes as shown in the diagram.

Contact Information

If you have any further questions or need support, please contact CDVI using the following contact details:

  • CDVI UK [UNITED KINGDOM IRELAND] – Phone: +44 (0)1628 531300 – Website: www.cdvi.co.uk
  • CDVI NORDIC [SWEDEN – DENMARK NORWAY FINLAND] – Phone: +46 (0)31 760 19 30 – Website: www.cdvi.se
  • CDVI AMERICAS [CANADA – USA – LATAM] – Phone: +1 866 610 0102 – Website: www.cdvi.ca
  • CDVI BENELUX [BELGIUM – NETHERLAND LUXEMBOURG] – Phone: +32 (0) 56 73 93 00 – Website: www.cdvibenelux.com

PRODUCT PRESENTATION

  • Surface mount
  • High corrosion resistance
  • Safety rope
  • No mechanical wear
  • No residual magnetism
  • Ease of installation
  • Recommended for interior use
  • Fail safe (Door unlocked when power off)
  • Holding force: 500 kg
  • Visual indication (Blue = Locked ; Green = Open)
  • Built-in varistor: built-in electronic protection to eliminate back EMF
  • Dimensions (L x W x D): 272 x 66 x 40 mm
  • Armature plate dimensions (L x W x D): 185 x 60 x 12 mm
  • Power supply: 12-24V dc
  • Consumption: 290 mA @ 12V dc 145 mA @ 24V dc

SYMBOLS

  • IP42
  • WEEE & RoHS
  • CE Certification
  • UKCA Certification

PACKAGE CONTENT

ELECTRICAL CONNECTIONS

12V dc Default setup

Terminal Description
+ 12 or 24V dc
0V
N.C NC (Normally closed)
COM COM
N.O NO (Normally open)

The NO/NC signal only switches when the door is closed with the power switched on.

Voltage selection jumpers

IMPORTANT NOTE

  • Check the jumper position before connecting the lock to the input current. Having it in the wrong position could damage the lock. This type of damage is not covered by the warranty.
  • Make sure that the magnet and the armature meet evenly over their entire facing surfaces.

The armature plate must be able to pivot slightly about its center mounting screw to compensate for any door misalignment.

Recommended power supplies

Installation Instructions

MOUNTING RECOMMENDATIONS

Armature plate

  • It is vital that the magnetic lock and armature plate are securely fixed to their supports.
  • The magnetic lock and the armature plate must be aligned.
  • The armature plate must be mounted “floating” around the central mounting screw to compensate for any misalignment of the door.

The security rope

  • Throughout its life, an electro-magnetic lock is subject to an accumulation of repeated shocks and stresses at the fixing points on the door frame.
  • Frequent opening and closing of the door as well as attempts of opening a locked door or acts of vandalism can cause the maglock to detach from its mounting support or bracket. In order to avoid the risk of the electro-magnetic lock falling, the two safety ropes can be installed to guarantee the safety of users. (see diagram above).

CONNECTION DIAGRAMS

(CONFORMS NF S61-937 – PV n° SD 18 00 59)

Synoptic 1

  • BBG: Glass breakage box
  • The BBG must be placed close to the emergency exit and be accessible in the direction of the evacuation.

Synoptic 2

  • The BRC box is essential for NF S61-937 compliance and must be reset by pressing button l1 located inside of the box.

Synoptic 3

  • The BRC box is essential for NF S61-937 compliance and must be reset by pressing button l1 located inside of the box.
  • The BBG must be placed close to the emergency exit and be accessible in the direction of the evacuation.

MAINTENANCE / TROUBLESHOOTING

In order to sustainably maintain the performance of your powered safety devices, we recommend :

  1. Perform a periodic functional test of your facility.
  2. Visually inspect the condition of different components of the installation in order to prevent deterioration of the wiring and the appearance of rust on the surfaces of electromagnetic devices.
  3. Systematically correct any anomaly of a nature compromise the security of your installation.

Reference should also be made to the standard NF S61-933 concerning the rules of operation and maintenance.

CDVI FRANCE + EXPORT

  • 31, av. du Général Leclerc
  • 93500 PANTIN – France
  • Tél: +33 (0)1 48 91 01 02
  • www.cdvi.fr

CDVI NORDIC

  • [SWEDEN – DENMARK –
  • NORWAY FINLAND]
  • Tél: +46 (0)31 760 19 30
  • www.cdvi.se

CDVI UK

  • [UNITED KINGDOM –
  • IRELAND]
  • Tél: +44 (0)1628 531300
  • www.cdvi.co.uk

CDVI AMÉRIQUES

  • [CANADA – USA – LATAM]
  • Tél: +1 866 610 0102
  • www.cdvi.ca

CDVI BENELUX

CDVI SUISSE

CDVI IBÉRICA

CDVI ITALIA

  • Tél: +39 0321 90 573
  • Fax: +39 0321 90 8018
  • www.cdvi.it

CDVI TAIWAN

CDVI CHINA

CDVI MAROC

CDVI POLSKA

CDVI GERMANY

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals