VISTA PROFESSIONAL OUTDOOR LIGHTING JB-250 In Ground Junction Box Instruction Manual

June 1, 2024
VISTA PROFESSIONAL OUTDOOR LIGHTING

VISTA PROFESSIONAL OUTDOOR LIGHTING JB-250 In Ground Junction Box

VISTA-PROFESSIONAL-OUTDOOR-LIGHTING-JB-250-In-Ground-Junction-Box-
product

Product Specifications

  • Model: JB-250
  • Product: Junction Box
  • Compliance: National Electrical Code (NEC) and local codes
  • Connector Type: UL Listed wire connectors
  • Material: Housing – Weather-resistant material
  • Dimensions: 10″ diameter for hole, flush to 1/8″ above grade

Product Usage Instructions

Junction Box Installation

  1. Dig a hole approximately 10″ in diameter to a depth that ensures the top of the fixture is flush to 1/8″ above grade.
  2. Use pea gravel or sand for seating the housing to aid in positioning.
  3. Ensure all dirt and debris are removed from the gasket sealing surface to prevent leakage.

NOTE: Always follow the National Electrical Code (NEC) and local codes during installation to avoid warranty voidance and potential injury or damage.

Frequently Asked Questions (FAQ)

  • Q: What type of wire connectors should be used for connections?
    A: UL Listed wire connectors should always be used for connections to ensure safety and compliance.

  • Q: Can the design of the fixture be modified without notification?
    A: Yes, Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the fixture without further notification.

INSTALLATION INSTRUCTIONS

WARNING: Junction boxes must be installed in accordance with the National Electrical Code (NEC) and local codes. Failure to do so will void the warranty and may result in serious injury and/or damage to the luminaire.
NOTE: Always use UL Listed wire connectors for connections.
NOTE: Save these instructions for future reference.

JUNCTION BOX INSTALLATION:

  1. Dig hole approximately 10” diameter to a depth suitable to make top of fixture flush to 1/8” above grade. Pea gravel or sand is recommended for seating the housing to aid positioning.

  2. Install conduit through ½” NPT openings on bottom (or side) of junction box using Teflon tape or other thread sealant. Using plug (provided), seal unused conduit entry if required.
    NOTE : UL listed flexible conduit is recommended for in and out connections to ease fixture position and adjustment during installation.

  3. Thread the luminaire to the Junction Box cover hub.

  4. If desired, tighten the locking screw located on underside of Junction Box cover.

  5. Support Junction Box housing in selected position using standard masonry procedures.

  6. Pull supply wires (line in), through conduit into wire compartment.

  7. Wire fixture as required using silicone filled safety connectors.

  8. Replace silicone rubber gasket and cover, and tighten screws evenly.
    NOTE: Failure to remove all dirt and debris from gasket sealing surface may cause leakage and void the warranty.

VISTA-PROFESSIONAL-OUTDOOR-LIGHTING-JB-250-In-Ground-Junction-
Box-

Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the fixture shown without further notification.

1625 Surveyor Avenue • Simi Valley, CA 93063 • 805-527-0987 • (800) 766-VISTA (8478) FAX: (888) 670-VISTA (8478) • email@vistapro.comwww.vistapro.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals