levenhuk Wezzer Base L50 Thermometer User Manual
- June 5, 2024
- levenhuk
Table of Contents
Wezzer Base L50 Thermometer
User Manual
Base station
1 Time display | 6 Outdoor temperature |
---|---|
2 Low battery indicator | 7 Sensor connection status |
3 Indoor MIN./ MAX. temperature record | 8 SET button |
4 Indoor temperature | 9 MEM button |
5 Outdoor MIN./ MAX. temperature record | 10 Battery compartment |
Sensor
1 Temperature | 6 RESET button |
---|---|
2 Humidity | 7 Channel switch (1—3) |
3 Current channel | 8 Battery compartment cover |
4 LED indicator | 9 Battery compartment |
5 Wall mount hole |
The kit includes a base station, sensor, user manual, and warranty.
Also required (not included):
2 AAA batteries for the sensor
2 AAA batteries for the base station
Getting started
Base station
- Open the battery compartment cover (10) and insert 2 batteries according to the correct polarity. Close the cover.
- Wait until the indoor temperature is displayed on the base station.
Sensor
- Open the battery compartment cover (8). The sensor should be operated on channel 1.
- Insert 2 batteries according to the correct polarity. Close the cover.
- To re-establish the sensor connection manually, press RESET using a pin.
Sensor connection
-
Place the base station and the remote sensor within the effective transmission range.
Ensure that the channels are assigned after you set up the power supply for the base station and all the sensors. -
If the reception is successful, the display will show the temperature of the respective outdoor sensor. If the values are not received from a channel, “—” appears on the display. Check the batteries and try it again. Check if there is any source of interference.
-
When changing batteries, replace the batteries first in the base unit, and then in all the sensors, to re-establish the connection. If an adapter supplies power to any of the devices, briefly disconnect the power to that device when replacing the batteries. If you change the batteries only in one of the devices (for example, in the sensor), the signal may not be received correctly.
-
The effective range may differ depending on the unit’s position. Due to interference (various remote control devices, etc.), the maximum distance between the base unit and the sensor may be significantly reduced. In such cases, we suggest moving the base unit and sensor a little. Sometimes it is enough to move one of these units a few inches!
NOTE! Although the sensor is weather-resistant, never place it in direct sunlight or in the rain or snow.
Time setting
Press SET and hold it for 3 seconds. The digits that are to be set are
flashing. Press MEM to change the value, and then press SET to continue.
The setting order: 12/24h > Hours > Minutes.
Temperature units
Press SET to switch between ℃ and ℉.
History record
Press MEM to display the MAX. and MIN. temperature values.
Hold MEM to clear the MAX. and MIN. IN/OUT temperature record.
Specifications
Base station
Temperature, units of measurement | °F, °C |
---|---|
Operating temperature range (indoors) | 0… +50°C (+32… +122°F) |
Time format | 24 hours, 12 hours |
Screen | monochrome |
Power supply | 2 AAA batteries (not included) |
Dimensions | 75×37.65x105mm (2.9×1.4×1 in.) |
Wireless sensor | 1 pc. (included) |
Sensor
Radio signal frequency | 433.92MHZ |
---|---|
Radio signal radius | 100m (328ft.) (in an open area) |
Operating temperature range (outdoors) | –30… +60°C (–22… +140°F) |
Operating humidity range (outdoors) | 20… 95% |
Power supply | 2 AAA batteries (not included) |
Dimensions | 40x21x120mm (1.5×0.8×4.7in.) |
The manufacturer reserves the right to make changes to the product range and specifications without prior notice.
Care and maintenance
-
Take the necessary precautions when using the device with children or others who have not read or who do not fully understand these instructions.
-
Do not try to disassemble the device on your own for any reason. For repairs and cleaning of any kind, please contact your local specialized service center.
-
Protect the device from sudden impact and excessive mechanical force.
-
Store the device in a dry, cool place away from hazardous acids and other chemicals, away from heaters, open fires, and other sources of high temperatures.
-
Operate the device only in a completely dry environment and do not touch the device with wet or damp body parts.
-
Only use accessories and spare parts for this device that comply with the technical specifications.
-
Check this device and its cables and connections for any possible damage before use.
-
Never attempt to operate a damaged device or a device with damaged electrical parts!
Damaged parts must be replaced immediately by an authorized service agent. -
If a part of the device or battery is swallowed, seek medical attention immediately.
-
Children should use the device under adult supervision only.
Battery safety instructions
Always purchase the correct size and grade of battery most suitable for the
intended use.
Always replace the whole set of batteries at one time; take care not to mix
old and new ones or batteries of different types. Clean the battery contacts
and also those of the device prior to battery installation. Make sure the
batteries are installed correctly with regard to polarity (+ and –). Remove
batteries from equipment that is not to be used for an extended period of
time. Remove used batteries promptly. Never short-circuit batteries as this
may lead to high temperatures, leakage, or explosion. Never heat batteries in
order to revive them. Do not disassemble batteries. Remember to switch off
devices after use. Keep batteries out of the reach of children, to avoid the
risk of ingestion, suffocation, or poisoning.
Utilize used batteries as prescribed by your country’s laws.
Levenhuk International Lifetime Warranty
All Levenhuk telescopes, microscopes, binoculars, and other optical products,
except for their accessories, carry a lifetime warranty against defects in
materials and workmanship.
A lifetime warranty is a guarantee of the lifetime of the product on the
market. All Levenhuk accessories are warranted to be free of defects in
materials and workmanship for six months from the purchase date. The warranty
entitles you to the free repair or replacement of the Levenhuk product in any
country where a Levenhuk office is located if all the warranty conditions are
met.
For further details, please visit:
www.levenhuk.com/warranty
If warranty problems arise, or if you need assistance in using your product,
contact the local Levenhuk branch.
levenhuk.com
Levenhuk Inc. (USA): 928 E 124th Ave. Ste D, Tampa, FL 33612,
USA, +1 813 468-3001,
contact_us@levenhuk.com
Levenhuk Optics s.r.o. (Europe): V Chotejně 700/7, 102 00 Prague 102,
Czech Republic, +420 737-004-919, sales-info@levenhuk.cz
Levenhuk® is a registered trademark of Levenhuk, Inc.
© 2006—2022 Levenhuk, Inc. All rights reserved.
20220420
References
- Levenhuk’s official website in USA
- Доживотна гаранция на Levenhuk – Официален уебсайт на Levenhuk в България
- Levenhuk Limited Warranty – Levenhuk’s official website in USA
- Doživotní záruka společnosti Levenhuk – Oficiální webové stránky Levenhuk pro Českou republiku
- Levenhuk Lebenslange Garantie – Die offizielle Website von Levenhuk in Deutschland
- Garantía internacional de por vida Levenhuk – Web oficial de Levenhuk en España
- Levenhuk Lifetime Warranty – Levenhuk’s official website in USA
- A Levenhuk élettartamra szóló szavatossága – A Levenhuk hivatalos magyarországi weboldala
- Gwarancja bezterminowa Levenhuk – Oficjalna witryna internetowa Levenhuk w Polsce
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>