levenhuk 33612 Walkie Talkie User Manual
- June 5, 2024
- levenhuk
Table of Contents
WALKIE-TALKIE
User Manual
1 Antenna | 13 Keypad locked |
---|---|
2 TX/RX icon | 14 Low battery indicator |
3 Volume level | 15 Talk button |
4 UP button | 16 VOX activated |
5 Monitor button | 17 Scanning |
6 On/Off button | 18 Channel/Menu item |
7 DOWN button | 19 CTCSS tone |
8 Earphones jack | 20 Flashlight on/off |
9 Speaker | 21 Scan button |
10 Microphone | 22 Flashlight |
11 MENU button | 23 Fastener |
12 Call button | 24 Pocket clip |
Getting started
Press the fastener (23) and pull the pocket clip (24) gently. Open the battery compartment cover and insert 4 AAA batteries according to the correct polarity. Close the cover until it clicks. Repeat the same steps with the second device.
Using the walkie-talkie
To turn the device on, press and hold the On/Off button (6) for 3 seconds.
The volume level is controlled by the UP (4) and DOWN (7) buttons.
Both walkie-talkies must be tuned to the same channel and CTCSS tone/DCS code
(if used), so that you can communicate. Press the MENU button (11) — the
channel digit will start blinking. Select one of the channels using the UP (4)
and DOWN (7) buttons and press the TALK button (15) to confirm the choice. To
select the CTCSS tone/
DCS code for the current channel, press the MENU button (11) twice, specify
the encoding type, and then one of the codes. To save the settings, press the
TALK button (15).
To call the other person, press the CALL button (12). During the conversation,
the transfer icon (TX) will be shown on the screen.
Press the TALK button (15) to send a voice message and keep it pressed while
speaking. After the button is released, the device will give a short beep
tone, indicating that the device has switched to receiving mode. To turn the
backlight on, press any button except the MENU button (11) and the monitoring
button (5). To reset to the factory settings turn the device off, press the UP
button (4) and turn the device on again.
Other functions
Monitoring — is used in case of an unstable signal. It disables the squelch
function so that all the signals on the selected channel become audible.
Scan — checks all channels for activity, stopping at each channel where
activity is detected. Press the TALK button (15) to stop on the selected
channel.
VOX — activates voice-activated transmission. Using VOX and connecting a
headset, you can go on the air without pressing buttons. VOX mode is switched
on/off via the MENU button (11).
Keypad lock — allows you to exclude the accidental pressing of buttons.
To activate this mode, press and hold the MENU button (11) for 2 seconds.
The TALK and CALL buttons will remain active!
Squelch — turns on automatically.
Specifications
Frequency range | 400—470MHz |
---|---|
Channels | 22 |
Radio signal radius | up to 3km /1.8mi. |
Squelch | + |
VOX | + |
Monitoring | + |
Scan function | + |
Power source | 4 AAA batteries (for each device) |
Transmission power | 0.5W |
Operating temperature range | –20… +50°C / –4… +122°F |
Care & maintenance
Do not use the device in potentially explosive environments or while riding a
bicycle or driving a car or any other vehicle.
Consult your doctor about the safety of the device regarding any medical
device you may be using.
Do not use the device near radio sources as it may cause interference.
Use a soft, damp cloth to clean the device. Do not use any ethanol- or
acetone-based fluids on it.
levenhuk.com
Levenhuk Inc. (USA): 928 E 124th Ave. Ste D, Tampa, FL 33612,
USA, +1 813 468-3001, contact_us@levenhuk.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>