Baby Brezza BRZ0069 Sterilizer Dryer Advanced Instruction Manual
IMPORTANT SAFEGUARDS
When using electrical appliances, basic safety precautions should always be followed, including the following:
-
Read all instructions carefully before using your sterilizer.
-
Ensure that the supply voltage marked on the appliance corresponds with your power supply.
-
If there is any visible damage to the appliance, the plug or to the supply cord, disconnect the appliance immediately and do not use it.
-
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or a similarly qualified person in order to avoid a hazard.
-
Do not allow children to touch or use the appliance. The appliance becomes very hot and the steam can cause severe scalding.
-
Do not move the appliance when it is in use or contains hot liquids.
-
Do not touch the hot surfaces.
-
Do not place the appliance on or near hot surfaces, in a heated oven or near a gas or electric heater.
-
Unplug the appliance from the power supply before cleaning or storage.
-
Do not immerse the supply cord, plug or base unit in water or any other liquid.
-
This Sterilizer base does not contain any user serviceable parts inside. Do not dismantle.
-
This appliance is for indoor household use only. Do not use outdoors.
-
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
-
a) Short power-supply cord is provided to reduce the risks resulting from becoming entangled in or tripping over a longer cord.
b) Extension cords are available and may be used if care is exercised in their use.
c) If an extension cord is used: The marked electrical rating of the extension cord should be at least as great as the electrical rating of the appliance; The longer cord should be arranged so that it will not drape over the countertop or tabletop where it can be tripped over, snagged, or pulled on unintentionally (especially by children). -
Children should be supervised to ensure that they do not play with the appliance. User maintenance shall not be made by children with supervision.
-
Not for space heating purpose.
-
Always use on a level heat resistant surface.
-
Always keep the electric sterilizer and its plug out of reach of small children.
-
To disconnect, turn any control “off”, then remove plug from wall outlet.
-
Ensure water has been added to the base unit before the sterilization cycle is switched on.
-
Always add 165ml of distilled water before use. If you put too little or too much water into the sterilizer, the sterilization eficiency may not be reached.
-
Always unplug from the electric outlet when not in use. Allow to cool before putting on or taking off any parts.
-
Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions or has been damaged in any manner. Return appliance to the nearest authorized service facility for examination, repair, or adjustment.
-
The use of accessory attachments is not recommended by the appliance manufacturer as this may cause injuries.
-
This sterilizer is intended to be used in household and similar application such as a. staff kitchen areas in shops, offices and other working environments. b. farm houses. c. by clients in hotels, motels and other residential type of environments. d. bed and breakfast.
-
Do not open while in use as this product contains boiling water. Beware of escaping steam from the vent holes in the lid.
-
Allow at least 30 minutes interval between operations and make sure the unit has been cooled down before pressing the start button for sequential use.
-
Steam escaping from the unit can cause burns. Always allow 5 minutes to cool down after the cycle finishes before lifting the lid.
-
To provide continued protection against risk of electric shock, connect to properly grounded outlets only.
-
CAUTION: Risk of electric shock, disconnect electric power before servicing.
-
Use only distilled water, bottled water or fresh running water to sterilize.
-
Never use any additives.
-
Do not let cord hang over edge of table or counter or touch hot surfac
-
Except cleaning , any other servicing should be performed by an authorized service representative.
-
After heating or all the water is removed from the sterilizer base, the heater surface is subject to residual heat after use.
-
This appliance can be used by children aged from 8 years and above and reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning used of the appliance in a safe way and understand the hazards involved.
-
Avoid spillage on the connector.
-
The appliance potential injury from misuse. Such as putting liquid that other than water to the sterilizer base. 39. This appliance not intended for food or infant formula warming and cooking.
In addition, instructions are also available in an alternative format such as
on a website or on request from the user
in a format such as a DVD or For an electronic copy of this manual, please
contract our after sales support centre.
This marking indicates that products should not be disposed of with other household wastes. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or Contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.
SAVE THESE INSTRUCTIONS
Sterilizer Dryer Parts
TECHNICAL DATA
Supply voltage: 220-240V ~ 50-60Hz Power: 750W Model: BRZ0069/BRZ0069EU
Set-up and Use
Before placing items in the appliance for sterilization it is important that
All bottles, pump parts and accessories must be EMPTY, CLEAN & FULLY
RINSED BEFORE USE in this sterilizer drye
-
Place the appliance on a flat surface where it is out of reach of children and it will not be knocked or moved during operation.
-
Remove the lid, baskets and accessory rack from the sterilizer base.
-
Pour water on the base/heater surface to MAX line (165ml/5.5oz).
Never fill past MAX line. We recommend using distilled water to avoid mineral scale build-up on the heating plate. However, you can use bottled water or tap water but you may need to descale more frequently. -
Place the lower basket on the base.
-
Place clean bottles with their opening facing downward on the bottle posts
-
Place the accessory tray in the lower basket (tray not for use with tall bottles).
-
Place bottle accessories on the accessory rack (nipples, collars, caps, etc)
-
Place the upper basket on top of the lower basket, ensuring that it fits securely without any gaps.
-
Place breast pump parts or more accessories in the upper basket.
-
Press the On/Off button once and the function icons will light up. Choose your desired function following the instructions below. If there is no selection of function after pressing on/o button, the
appliance will automatically switch off.
Automatic Sterilize/Dry Function:
-
Choose the drying time (after steam sterilization): Press the Sterilize/Dry button 1 time for 30 minute dry time, 2 times for 45 minute dry time, 3 times for 60 minute dry time. The sterilize/dry cycle will start 3 seconds after the last button press.
-
When the sterilization cycle starts, the timer will count up second-by-second for the duration of the sterilization cycle.
-
When the sterilization cycle is complete, the appliance will beep, pause for
3 seconds and begin the drying cycle for the amount of time selected in
step 1. The timer on the timer will count down second-by-second until it reaches 00:00. -
When the drying cycle is completed, the appliance will beep 5 times and switch off automatically.
Sterilize only function:
- Press the Sterilize button one time, the timer will display “00:00” and the steam icon. The sterilization cycle will start 3 seconds after pressing the sterilize button and the timer will count up second-by-second for the duration of the sterilization cycle.
- When the sterilization cycle is complete, the appliance will beep 5 times and switch off automatically.
Dryer only function:
- Press the Dry button 1 time for 30 minute dry time, 2 times for 45 minute dry time, 3 times for 60 minute dry time. The drying cycle will start 3 seconds after the last button is pressed and the timer on the timer will count down second-by second until it reaches 00:00.
- When the drying cycle is completed, the appliance will beep 5 times and switch of automatically.
Caution: If it is necessary to remove water from the base, always POUR AWAY
FROM FAN OPENING.
Note water pour direction icon on base, and pour in direction of arrow.
Cleaning
- Always unplug your product before cleaning.
- Do not immerse the base, the supply cord or the plug in water or other liquids.
- Do not clean base under water tap.
- Use a soft damp cloth to clean the base and control console.
- Never use abrasive pads to clean the plastic parts of the machine.
- The lid, accessory rack can be cleaned in hot soapy water.
- Mineral residue, particularly in hard water areas, may deposit on the heating plate after a few sterilization cycles. To avoid scale build up, wipe the surfaces with a soft moist cloth after each operation.
- Deposits can be removed with scale removers or by leaving 60ml/2oz water and vinegar solution (50/50 water & vinegar mix) on the heating plate for approximately 30 minutes. The plate should then be wiped clean with a clean, dry cloth. Some discoloration spots may remain after cleaning with a vinegar solution, but these are harmless.
- Do not use abrasives or solvents for cleaning; they may damage the appliance and the surface of the heating plate.
Modular set-up options
Upper & Lower Baskets With Accessory Tray For use with short bottles, accessories & pump parts.
Upper & Lower Baskets WITHOUT Accessory Tray
For use with tall bottles, and accessories.
Lower Basket only With Accessory Tray For use with short bottles, accessories & pump parts.
Upper Basket only WITHOUT Accessory Tray For use with accessories pacifiers and small items.
Breast pump parts and any other items safe for steam sterilization can be
placed in the lower or upper baskets. Try dierent configurations to find what
set-up works best for you.
TIP: For best drying performance, Do not overload the Sterilizer Dryer.
Troubleshooting
If you can not remedy problems by using the troubleshooting chart above,
visit babybrezza.com/pages/international to locate your local customer service
representative.
Using the included tongs
The tongs can be inserted and stored in the upper basket or the accessory
tray.
When the tongs are clicked into place, they can be used to lift the basket or
tray. Gently squeeze the tongs to remove them.
They can also be used to grasp parts and bottle nipples in the sterilizer