TotalPond 52301 UV Pond Clarifier Instruction Manual

June 5, 2024
TotalPond

TotalPond 52301 UV Pond Clarifier Instruction Manual

TotalPond 52301 UV Pond Clarifier Instruction Manual

Thank you for choosing TotalPond®
BEFORE RETURNING TO STORE
Contact Customer Care:
1-888-412-6001

Questions, problems, missing parts?
customercare@totalpond.com
Visit totalpond.com for a step by step guide and videos

WARNINGS AND CAUTIONS

IMPORTANT SAFETY INFORMATION
Please read these instructions carefully prior to starting up the unit! The water system on which the operation of this product is based requires utmost care and maintenance, possibly also the use of chemicals, in order to prevent and keep the occurrence of microorganisms and harmful bacteria, especially legionellae that are responsible for legionnaire’s disease, under control. Non-observance of this information about correct maintenance and care can entail the spreading of harmful bacteria. Due to the fact that for decorative purposes, water nozzles distribute water in the air, water droplets containing harmful bacteria can enter your lungs and cause life-threatening diseases.

It is the responsibility of the owner of the water system and its attendant units to ensure their maintenance and care in compliance with the laws, directives and instructions laid down for this purpose. In order to avert harmful contamination, we urgently recommend the user to ensure cleaning and care of the water system and the water feature including the nozzle, and to take all necessary measures to maintain the technical units, such as pumps, tubing, connectors, underwater lighting, and nozzles to keep them in functional order in line with safety aspects. However, the maintenance and care obligation is not limited to the technical products supplied, but encompasses the entire system.

We also recommend the owner to keep records of the dates when maintenance and care was carried out, and to document all water tests made in conjunction with the water feature. The owner is solely responsible for guaranteeing the safety of the water feature. Use or maintenance of the units sold and the system are beyond Geo Global Partner’s influence. Geo Global Partners can only be held liable for manufacturing faults of TotalPond® units.

WARNING

  • WARNING ­ Improper connection of the appliance-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded. Do not modify the plug provided with the appliance; if it will not fit the outlet, have a proper outlet installed by a qualified technician.
  • Do not operate any appliance if it has a damaged cord or plug, or if it is malfunctioning or if it is damaged in any manner.
  • Always unplug the appliance from the outlet before putting on or taking off parts, before cleaning or when not in use.
  • Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).
  • Risk of Electric Shock – Do not use the UV filter if the quartz tubing around the lamp is broken. Immediately unplug and seek an authorized repair service or discard the unit.
  • GROUNDING INSTRUCTIONS ­ This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an appliance-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with all local codes and ordinances.

CAUTION

  • UV light may cause irritation to the skin and/or eyes. Avoid exposure.
  • DANGER ­ ULTRAVIOLET RADIATION ­ Diconnect Power Before Replacing Lamp.
  • Prolonged or repeated exposure to UV light may have adverse physical effects including, severe damage to your skin and eyes. Seek immediate medical attention for overexposure to UV radiation.
  • Keep the cord away from high temperatures or other heat sources.
  • Do not lift the light by its power cord.
  • This light assembly has not been investigated for use in swimming pools or hot tubs.

IMPORTANT NOTES

  • This product is designed to prohibit its operation unless it is fully assembled with the lamp base screwed completely into the housing.
  • UV rays are harmful to your eyes and skin. The indicator portal will remove the harmful effects of the UV light but still allow you to see the bulb operating.
  • Do not attempt to operate this product unless the lamp is completely assembled within the light housing.
  • This product conforms to the Code of Federal Regulations (CFR) requirements including, Title 21, Chapter 1, Subchapter J, Radiological Health.

TotalPond 52301 UV Pond Clarifier Instruction Manual -
Specifications

PACKAGE CONTENTS

TotalPond 52301 UV Pond Clarifier Instruction Manual - PACKAGE
CONTENTS

PREPARATION

Before beginning assembly or operation of product, make sure all parts are present. Compare parts with package contents list and diagram. If any part is missing or damaged, do not attempt to assemble, install or operate the product. Contact Customer Care for replacement parts.

  • Estimated Assembly Time: 5 minutes
  • Tools required for assembly: hacksaw

OPERATION INSTRUCTIONS

Step 1. 3/4 in. ID tubing is recommended for optimum performance. Check your pump to determine a compatible tubing size. If using 1/2 in. ID tubing continue to step 2.

If using 3/4 in. ID tubing, trim the tubing adapter using a hacksaw at the location indicated.

If using 1 in. ID tubing, trim the tubing adapter using a hacksaw at the top of the widest tier.
Step 2. Place the tubing adapter on the left hole of the UV Clarifier and use a gasket for it to be sealed tightly when fastened.
Hand tighten the locking ring outside the tubing adapter for it to be secured in place. Repeat for the right hole.

Step 3. Unplug your pump from an electrical source before connecting tubing. Connect tubing from the outlet of a pump to the inlet of the UV Clarifier.
NOTE: The inlet on the UV Clarifier is marked “IN”. Pump
and tubing are not included.

Step 4. Return water to the pond by connecting tubing to the outlet of the UV Clarifier and to the inlet of a water feature or return to the pond. You can reconnect 4
your pump into a properly grounded electrical outlet at this time.
Note: The outlet on the UV Clarifier is marked “OUT”.

Step 5. Connect the UV Clarifier into a properly grounded electrical outlet.

Step 6. Wait several seconds then check the indicator light to verify if the UV bulb is functioning properly.
NOTE: This UV clarifier includes a safety feature that will not allow the light to turn on if the lamp holder or locking ring are not securely fastened.

MAINTENANCE

To maximize the performance of the UV clarifier, periodically disassemble the filter to clean dirt and debris from the exterior of the glass tube and inside light housing. Check the UV bulb to make sure that it has nor burned out. Replace the bulb as necessary, or after every season.

TotalPond 52301 UV Pond Clarifier Instruction Manual -
MAINTENANCE

TROUBLESHOOTING

IF THE LIGHT FAILS TO OPERATE:

  • Check to make sure the power cord is plugged in and the light is getting power.
  • Check to make sure that the lamp holder is screwed completely into the body. (This product will not operate unless it is fully assembled with the lamp holder screwed completely into the body.)
  • Check bulb to make sure that it has not burned out. Replacement bulbs #52302 (#UVRB)

For more information on product maintenance and maintenance videos, visit www.totalpond.com

REPLACEMENT PARTS

TotalPond 52301 UV Pond Clarifier Instruction Manual - REPLACEMENT
PARTS

customercare@totalpond.com

WARRANTY

1 YEAR WARRANTY
www.totalpond.com/register

Date of purchase://_
Item number __

Questions? Call Customer Care at 1-888-412-6001

LIMITED WARRANTY
All pumps and electrical products are warranted to the user against defective material and workmanship, under normal working conditions. This warranty period begins on the date of purchase by the original purchaser.

APPLICATION
Warranty covers only properly installed and maintained units. Any damage or modification to the cord or to the unit will terminate the warranty. Pump warranty is limited to applications pumping fresh water in a pond or fountain only. Other liquid applications or extreme temperature uses must be approved in writing by the manufacturer. Receipt and product date code are required for warranty claims.

WARRANTY CLAIM
Warranty claims must be made by calling Customer Care (at 1-888412-6001). If the item is determined to be defective, you will be given authorization to return the defective part(s), freight pre-paid, along with proof of purchase.

DISPOSITION
The manufacturer will make a good faith effort for prompt disposition regarding all warranty claims. Returned product will be inspected to determine cause of failure before warranty is applied. Warranty does not cover any costs associated with the shipping, handling, installation or removal of products or parts subject to this warranty. For products damaged in transit, a claim should be filed with the carrier.

DISCLAIMER
Any oral statements made about the product by the seller, the manufacturer, the representatives, or any other parties do not constitute warranties, should not be relied upon by the user, and are not part of the contract for sale. The seller’s and manufacturer’s only obligation, and buyer’s only remedy shall be for the manufacturer to either replace and/or repair at the manufacturer’s sole discretion, the product as described above. Neither seller nor the manufacturer shall be liable for injury, loss or damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss arising from any cause whatsoever, no matter whether based upon warranty, contract, negligence or other misuse, and the buyer and user agree that no other remedy shall be available to them. Before using, the buyer and user shall determine the suitability of the product for the intended use, and assume all risk and liability whatsoever in connection therewith. The warranty and remedy described in this limited warranty is an exclusive warranty and remedy in lieu of any other warranty or remedy expressed or implied. All other warranties and remedies are hereby expressly excluded, including but not limited to any implied warranty or merchantability of fitness for any particular purpose. This warranty gives the buyer and user specific legal rights, and buyer and user may also have other rights which vary from state to state. Some states do not allow exclusioinis or limitations of incidental or consequential damages, so the above limitations or exclusions may not apply to you

Show us your ponds and projects! Share with us


TotalPond®
Need help? Call Customer Care at 1-888-412-6001 (US) or visit www.totalpond.com
©GeoGlobal Partners, LLC. TotalPond is a registered trademark of GeoGlobal Partners, LLC

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals