TotalPond 52676 800 GPH Pond Pump User Manual
- June 10, 2024
- TotalPond
Table of Contents
52676 800 GPH Pond Pump
User Manual
800 GPH POND PUMP
3028 LPH POMPE POUR BASSIN
3028 LPH BOMBA PARA ESTANQUES
Item #52676
52676 800 GPH Pond Pump
Questions, problems, missing parts? Contact Customer Care Monday – Friday
1-888-412-6001
customercare@totalpond.com
WARNINGS AND CAUTIONS
IMPORTANT SAFETY INFORMATION
Please read these instructions carefully prior to starting up the unit!
The water system on which the operation of this product is based requires
utmost care and maintenance, possibly also the use of chemicals, in order to
prevent and keep the occurrence of micro-organisms and harmful bacteria,
especially legionellae that are responsible for legionnaire’s disease, under
control. Nonobservance of this information about correct maintenance and care
can entail the spreading of harmful bacteria. Due to the fact that for
decorative purposes, water nozzles distribute water in the air, water droplets
containing harmful bacteria can enter your lungs and cause life-threatening
diseases.
It is the responsibility of the owner of the water system and its attendant
units to ensure their maintenance and care in compliance with the laws,
directives and instructions laid down for this purpose. In order to avert
harmful contamination, we urgently recommend the user to ensure cleaning and
care of the water system and the water feature including the nozzle, and to
take all necessary measures to maintain the technical units, such as pumps,
tubing, connectors, underwater lighting, and nozzles to keep them in
functional order in line with safety aspects. However, the maintenance and
care obligation is not limited to the technical products supplied, but
encompasses the entire system.
We also recommend the owner to keep records of the dates when maintenance and
care was carried out, and to document all water tests made in conjunction with
the water feature. The owner is solely responsible for guaranteeing the safety
of the water feature. Use or maintenance of the units sold and the system are
beyond GeoGlobal Partner’s influence. GeoGlobal Partners can only be held
liable for manufacturing faults of Total Pond® units.
WARNING
- Risk of electrical shock. This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
- Do not exceed the voltage shown on the pump.
- Always disconnect pump from the power source before beginning any maintenance or work on the pump.
- Inspect cord for damage before installation and/or maintenance. Replace the entire pump assembly if damage is found.
- Do not remove the grounding pin from the power cord plug.
- Risk of electrical shock – This pump has not been investigated for use in swimming pool or marine areas.
CAUTION
- This pump has been evaluated for use with fresh water only.
- Use a proper power source as indicated on the pump label.
- Keep the cord away from high temperatures or other heat sources.
- Do not pump heated liquids.
- Do not let the pump run dry. Pump must be completely submerged for proper operation and cooling.
- Operate in freshwater only. Avoid heavily chlorinated water and water with high pH levels.
- Do not lift the pump by its power cord.
PREPARATION
Before beginning assembly or operation of product, make sure all parts are present. Compare parts with package contents list and diagram. If any part is missing or damaged, do not attempt to assemble, install or operate the product. Contact Customer Care for replacement parts.
- Estimated assembly time: 5 minutes.
- No tools required for assembly.
PACKAGE CONTENTS
Part | Description | Qty |
---|---|---|
A | Pump | 1 |
B | 3/4 in. Tubing Adapter | 1 |
C | Inlet Screen | 1 |
OPERATION INSTRUCTIONS
Step 1. Connect the adapter to the outlet of the pump and attach tubing
to the adapter. Also attach the inlet screen to the inlet of the pump.
NOTE: Tubing is not included.
Step 2. Adjust the flow control to the lowest setting. Once the pump has
been turned on (after step 3) you may adjust the flow control to the preferred
setting.
Step 3. Place the pump into the water and connect to a properly grounded
electrical outlet.
SPECIFICATIONS
Max Flow Rate 800 GPH (at 0 ft.)
Max Pumping Height 13.9 ft. (at 0 GPH)
Power Consumption 52 watts / 1 amps
Cord Length 16 ft.
Lift (feet)
Flow Rates (GPH)
12| 130
11| 190
10| 243
9| 285
8| 322
7| 362
6| 412
5| 470
4| 528
3| 589
2| 650
1| 713
0| 800
Register your product online!
Use your smartphone camera to scan the QR code or visit our website
totalpond.com/register
Before installing your pump please write down the following information:
The 14 digit serial number located on the pump
MAINTENANCE & TROUBLESHOOTING
Always disconnect units from the power source before beginning any maintenance
or work on the unit.
Regular cleaning of the pump may be necessary depending upon the environment
in which it is operated. Clean the pump when it is visibly soiled or when a
drop in performance is detected.
Step 1. Remove the inlet screen.
Step 2. Remove the impeller housing to expose the impeller assembly.
Step 3. Remove the impeller assembly by gently pulling on the impeller
blades. The impeller is holding place by a magnet
Step 4. Use a soft cloth or brush and warm water to clean the impeller,
the inside of the impeller housing and the rotor housing.
Step 5. Reassemble all pump parts and place in water before reconnecting to the power source.
TROUBLESHOOTING
IF THE PUMP FAILS TO OPERATE:
-
Check to make sure the power cord is plugged in, the pump is getting power.
-
Check the pump outlet and any tubing, nozzles, spatters etc. for kinks or obstructions.
-
Remove the inlet screen and/or pump cover, and impeller housing to expose the impeller. Turn the impeller to ensure that it is not broken or jammed.
IF THE PERFORMANCE OF THE PUMP IS NOT SATISFACTORY OR THE PUMP DOES NOT FLOW EVENLY: -
Check to make sure the pump is completely submerged in water.
-
Check to make sure the impeller and the housing are clean.
-
Adjust flow control.
For product maintenance videos visit totalpond.com
REPLACEMENT PARTS
Visit our website: totalpond.com/replacement-parts or contact Customer Care Monday – Friday
1-888-412-6001
customercare@totalpond.com
WARRANTY
2 Year Warranty
LIMITED WARRANTY
All pumps and electrical products are warrantied to the user against defective
material and workmanship, under normal working conditions. This warranty
period begins on the date of purchase by the original purchaser.
APPLICATION
Warranty covers only properly installed and maintained units. Any damage or
modification to the cord or to the unit will terminate the warranty. Pump
warranty is limited to applications pumping fresh water in a pond or fountain
only. Other liquid applications or extreme temperature uses must be approved
in writing by the manufacturer. Receipt and product date code are required for
warranty claims.
WARRANTY CLAIM
Warranty claims must be made by calling Customer Care (at 1-888412-6001). If
the item is determined to be defective, you will be given authorization to
return the defective part(s), freight pre-paid, along with proof of purchase.
DISPOSITION
The manufacturer will make a good faith effort for prompt disposition
regarding all warranty claims. Returned product will be inspected to determine
cause of failure before warranty is applied. Warranty does not cover any costs
associated with the shipping, handling, installation or removal of products
or parts subject to this warranty. For products damaged in transit, a claim
should be filed with the carrier.
DISCLAIMER
Any oral statements made about the product by the seller, the manufacturer,
the representatives, or any other parties do not constitute warranties, should
not be relied upon by the user, and are not part of the contract for sale. The
seller’s and manufacturer’s only obligation, and buyer’s only remedy shall be
for the manufacturer to either replace and/or repair at the manufacturer’s
sole discretion, the product as described above. Neither seller nor the
manufacturer shall be liable for injury, loss or damages for lost profits,
lost sales, injury to person or property, or any other incidental or
consequential loss arising from any cause whatsoever, no matter whether based
upon warranty, contract, negligence or other misuse, and the buyer and user
agree that no other remedy shall be available to them. Before using, the buyer
and user shall determine the suitability of the product for the intended use,
and assume all risk and liability whatsoever in connection therewith. The
warranty and remedy described in this limited warranty is an exclusive
warranty and remedy in lieu of any other warranty or remedy expressed or
implied. All other warranties and remedies are hereby expressly excluded,
including but not limited to any implied warranty or merchantability of
fitness for any particular purpose. This warranty gives the buyer and user
specific legal rights, and buyer and user may also have other rights which
vary from state to state. Some states do not allow exclusionism or limitations
of incidental or consequential damages, so the above limitations or exclusions
may not apply to you.
02/23 ©GeoGlobal Partners, LLC.
Total Pond is a registered trademark of
Visit WWW.TOTALPOND.COM for information and tips.
Please call Customer Care before returning item to store:
1-888-412-6001
References
- TotalPond Water Gardening
- Register – TotalPond
- Replacement Parts – TotalPond
- TotalPond Water Gardening
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>