TotalPond 52223 330-560 GPH Pond Pumps Instruction Manual

June 10, 2024
TotalPond

52223 330-560 GPH Pond Pumps
Instruction ManualTotalPond 52223 330-560 GPH Pond
Pumps

Thank you for choosing TotalPond ®

Questions, problems, missing parts? Contact Customer Care
Monday – Friday
1-888-412-6001
customercare@totalpond.com

WARNINGS AND CAUTIONS

IMPORTANT SAFETY INFORMATION
Please read these instructions carefully prior to starting up the unit!
The water system on which the operation of this product is based requires utmost care and maintenance, possibly also the use of chemicals, in order to prevent and keep the occurrence of micro-organisms and harmful bacteria, especially legionellae that are responsible for legionnaire’s disease, under control. Nonobservance of this information about correct maintenance and  care can entail the spreading of harmful bacteria. Due to the fact that for decorative purposes,  water nozzles distribute  water in the air, water droplets containing harmful bacteria can enter your lungs and cause  life- threatening diseases.
It is the responsibility of the owner of the water system and its attendant units to ensure their maintenance and care in compliance with the laws, directives and instructions laid down for this purpose. In order to avert harmful contamination, we urgently recommend the user to ensure cleaning and care of the water system and the water feature including the nozzle, and to take all necessary measures to maintain the technical units, such as pumps, tubing, connectors, underwater lighting, and nozzles to keep them in functional order in line with safety aspects. However, the maintenance and care obligation is not limited to the technical  products supplied, but encompasses the entire system.
We also recommend the owner to keep records of the dates when maintenance and care was carried out, and to document all water tests made in conjunction with the water feature. The owner is solely responsible for guaranteeing the safety of the water feature. Use or maintenance of the units sold and the system are beyond GeoGlobal Partner’s influence. GeoGlobal Partners can only be held liable for manufacturing faults of TotalPond® units.
WARNING

  • Risk of electrical shock. This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a  properly grounded, grounding-type receptacle.
  • Do not exceed the voltage shown on the pump.
  • Always disconnect pump from the power source before beginning any maintenance or work on the pump.
  • Inspect cord for damage before installation and/or maintenance. Replace the entire pump assembly if damage is found.
  • Do not remove the grounding pin from the power cord plug.
  • Risk of electrical shock – This pump has not been investigated for use in swimming pool or marine areas.

CAUTION

  • This pump has been evaluated for use with fresh water only.
  • Use a proper power source as indicated on the pump label.
  • Keep the cord away from high temperatures or other heat sources.
  • Do not pump heated liquids.
  • Do not let the pump run dry. Pump must be completely  submerged for proper operation and cooling.
  • Operate in freshwater only. Avoid heavily chlorinated water and water with high pH levels.
  • Do not lift the pump by its power cord.

PREPARATION

Before beginning assembly or operation of product, make sure all parts are present. Compare parts with package contents list and diagram. If any part is missing or damaged, do not attempt to assemble, install or operate the product. Contact Customer Care for replacement parts.

  • Estimated assembly time: 5 minutes.
  • No tools required for assembly.

PACKAGE CONTENTS

Part Description Qty
A Pump 1
B 3/4 in. Tubing Adapter 1
C Coupler  (#52224 only) 1

TotalPond 52223 330-560 GPH Pond Pumps - PACKAGE
CONTENTS

OPERATION INSTRUCTIONS

Step 1. For #52223, connect the adapter to the outlet of the pump and attach tubing to the adapter.For #52224, connect the adapter to the outlet of the pump with the coupler and attach tubing to the adapter
NOTE: Tubing is not included.

TotalPond 52223 330-560 GPH Pond Pumps - Tubing

Step 2. Adjust the flow control to the lowest setting. Once the pump has been turned on (after step 3) you may adjust the flow control to the preferred setting.
Step 3. Place the pump into the water and connect to a properly grounded electrical outlet.

SPECIFICATIONS

Pump #52223 #52224
Max Flow Rate 330 GPH (at 0 ft.) 560 GPH (at 0 ft.)
Max Pumping Height 7.2 ft. (at 0 GPH) 9 ft (at 0 GPH)
Power Consumption 27 watts / 0.4 amps 42 watts / 0.6 amps
Cord Length 16 ft. 16 ft.
Lift (feet) Flow Rates (GPH)
--- ---
8 70
7 99
6 79 198
5 148 284
4 185 342
3 219 395
2 264 476
1 303 546
0 330 560
52223 52224
Pumps

Before installing your pump please write down the following information:
The 14 digit serial number located on the pump


Item number:__
Date of purchase: / /_
Pump date code:mm yy__
/____
TotalPond 52223 330-560 GPH Pond Pumps - BAR code

MAINTENANCE & TROUBLESHOOTING

Always disconnect units from the power source before beginning any maintenance or work on the unit.
Regular cleaning of the pump may be necessary depending upon the environment in which it is operated. Clean the pump when it is visibly soiled or when a drop in performance is detected.
Step 1. Remove the inlet screen.
Step 2. Remove the impeller cover to expose the impeller assembly. Remove the impeller assembly by gently pulling on the impeller blades. The impeller is held in place by a manget
Step 3. Use a soft cloth or brush and warm water to clean the impeller, the inside of the impeller housing and the rotor housing.
Step 4. Reassemble all pump parts and place in water before reconnecting to the power source.

TROUBLESHOOTING

IF THE PUMP FAILS TO OPERATE:

  • Check to make sure the power cord is plugged in, the pump is getting power.
  • Check the pump outlet and any tubing, nozzles, spitters etc. for kinks or obstructions.
  • Remove the inlet screen and/or pump cover, and impeller cover to expose the impeller. Turn the impeller to ensure that it is not broken or jammed.

IF THE PERFORMANCE OF THE PUMP IS NOT SATISFACTORY OR THE PUMP DOES NOT FLOW EVENLY:

  • Check to make sure the pump is completely submerged in water.
  • Check to make sure the impeller and the housing are clean.
  • Adjust flow control.

For product maintenance videos visit totalpond.com

WARRANTY

2 Year Warranty
LIMITED WARRANTY
All pumps and electrical products are warrantied to the user against defective material and workmanship, under normal working conditions. This warranty period begins on the date of purchase by the original purchaser.
APPLICATION
Warranty covers only properly installed and maintained units. Any damage or modification to the cord or to the unit will terminate the warranty. Pump warranty is limited to applications pumping fresh water in a pond or fountain only. Other liquid applications or extreme temperature uses must be approved in writing by the manufacturer. Receipt and product date code are required for warranty claims.
WARRANTY CLAIM
Warranty claims must be made by calling Customer Care (at 1-888-412-6001).  If the item is determined to be defective, you will be given authorization to return the defective part(s), freight pre-paid, along with proof of purchase.

DISPOSITION
The manufacturer will make a good faith effort for prompt disposition regarding all warranty claims. Returned product will be inspected to determine cause of failure before warranty is applied. Warranty does not cover any costs associated with the shipping, handling, installation or removal of products or parts subject to this warranty. For products damaged in transit, a claim should be filed with the carrier.
DISCLAIMER
Any oral statements made about the product by the seller, the manufacturer, the representatives, or any other parties do not constitute warranties, should not be relied upon by the user, and are not part of the contract for sale. The seller’s and manufacturer’s only obligation, and buyer’s only remedy shall be for the manufacturer to either replace and/or repair at the manufacturer’s sole discretion, the product as described above. Neither seller nor the manufacturer shall be liable for injury, loss or damages for lost profits, lost
sales, injury to person or property, or any other incidental or consequential loss arising from any cause whatsoever, no matter whether based upon warranty, contract, negligence or other misuse, and the buyer and user agree that no other remedy shall be available to them. Before using, the buyer and user shall determine the suitability of the product for the intended use, and assume all risk and liability whatsoever in connection therewith. The warranty and remedy described in this limited warranty is an exclusive warranty and
remedy in lieu of any other warranty or remedy expressed or implied. All other warranties and remedies are hereby expressly excluded, including but not limited to any implied warranty or merchantability of fitness for any particular purpose. This warranty gives the buyer and user specific legal rights, and buyer and user may also have other rights which vary from state to state. Some states do not allow exclusioinis or limitations of incidental or consequential damages, so the above limitations or exclusions may not apply to you.

REPLACEMENT PARTS

Visit our website: totalpond.com/replacement-parts
or contact Customer Care Monday – Friday
****1-888-412-6001 customercare@totalpond.com

Register your product online!
Use your smartphone camera  to scan the QR code or visit our  website totalpond.com/register

02/23 ©GeoGlobal Partners, LLC.
TotalPond is a registered trademark of

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals