Dryflow DFEW02 EcoWave Hand Dryer User Manual
- June 5, 2024
- Dryflow
Table of Contents
EcoWave Hand Dryer
User Manual
Cleaning of the Filter Cartridge
Attention
Attention: If the airflow becomes weak, please clean the filter screen.
Generally, it needs to be cleaned one or two times a year. Do not clean with
water.
- Press the release levers at either side of the filter screen, then pull and get it out.
- Get the filter screen from the filter cartridge
- Clean the dust on the filter screen, do not wash. If there is too much dust, please replace
- Put the filter screen at the right position in the filter cartridge, and insert the filter cartridge into the body.
Features:
- It is equipped with an automatic infrared ray induction system, very easy to use, reducing waste, and no touch with the hands which effectively avoids pathogen cross infection and re-contamination.
- It has outstanding performance with enhanced technology.
- It has a unified high-speed motor with an RPM of 22000 and dries the hands in 10-15 seconds.
- This series product has over current protection, which effectively eliminates accidents.
- It is suitable for all departments in hospitals, schools, food and pharmaceutical manufacturers, office buildings, hotels, government agencies, and research institutions.
Technical Parameters:
Rated Voltage | AC220-240V | Waterproof Grade | IPX1 |
---|---|---|---|
Rated Frequency | 50/60Hz | Air Speed | 80m/s |
Rated Power | 950W | Sensing Distance | 12 +/- 3cm |
Ambient Temperature | 0 – 40 ºC | Drying Time | 10 – 15s |
Installation | Wall Mounting | Overall Size | 300275100mm |
Note Before Installation
Warning
- Do not fix in a place where water or water vapor is directed at the surface or in the bathroom where heavy moisture is present in order to avoid electric shock.
- You must commission a professional electrician to install it or else it has an electric shock hazard.
- You must cut off the power before installation.
- Install leakage circuit breakers to protect against fire hazards.
- Do not disassemble, repair, or make any alteration to this machine without authorization, otherwise, there is a risk of electric shock, fire, and other accidents.
Attention
-
Ensure that no other items are within 400mm of the outlet.
Do not install it above shining surfaces, otherwise prone to misoperation. -
The body should be firmly fixed to a smooth wall to avoid injuries.
-
Do not install the product in a place with corrosive or flammable gases or objects, it may cause fire or product failure and malfunction.
-
Do not install the product in an environment with excessive dust or high temperature, it may cause product damage.
Method of Installation
Maintenance:
-
Please cut off the power and clean the cover with natural detergent when it is dirty. The acid and alkalescent bathroom detergent and BEN, lacquer thinner, abrasive, etc. are forbidden.
Also, do not use a nylon brush to avoid scratching the surface. -
When cleaning the cover prevents water droplets from going into the machine, so as to avoid electric shock or short circuit.
-
It is better to cut off the power when not in use, to extend the service life.
-
If the power cord is damaged, it should be replaced.
-
If the machine breaks drown, cut off the power quickly, and do not use it, please commission a professional to repair it. Contact your supplier for further assistance.
Dryflow, 7 Riverside Court, Don Road, Sheffield, S9 2TJ. The UK.
+44 (0)114 3540047 | info@dryflow.co.uk |
www.dryflow.co.uk