Dryflow JF1G JetForce Pro Intelligent Hand Dryers User Manual
- June 5, 2024
- Dryflow
Table of Contents
Dryflow JF1G JetForce Pro Intelligent Hand Dryers
Featured
- Drying hands without contact for improved hygiene.
- Electricity cost saving because of drying hands at high speed.
- It’s economical & practical.
- Anti-damage timer for added peace of mind.
- Antibacterial & environmental materials, no pollution.
- Automatic heating, drying hands with warm air in winter and drying hands with cool air in summer.
Anti damage timer
Installed anti-damage timer, this machine will stop after working continuously for 25 seconds. Draw out your hands and then put your hands back into the dryer to continue use.
Specification
Rated voltage | AC220-240V~ | Motor | Brushless DC motor |
---|---|---|---|
Input power | 1650-2050W | Induction method | IR blocking |
Wind velocity | 95m/s | Protection class | IP24 |
Heating power | 1000-1200W | Dimensions | 300X220X685mm |
Net weight | 10.5kg |
WARNING personal injury accidents will happen if use improperly
-
Do not open the front panel.
-
This may cause an electric shock.
-
Supervise children at all times.
-
Do not let them play with the unit.
-
Do not use in a wet environment, for example, near a bath or a shower where it may get direct water and places where condensation may form, otherwise this may cause electric shock and unit malfunction.
-
Do not allow the unit to get wet, otherwise it will cause electric shock.
-
Do not modify and disassemble the unit unnecessarily.
-
Otherwise this may cause a fire, electric shock or personal injury.
-
Rated power is required.
-
If power tolerance is over +/- 10%, there will be breakdown.
-
If using incorrect power supply, fire, electric shock and machine malfunction will happen.
-
Please, use dedicated socket.
-
If using together with other appliances, the socket may cause abnormal heat leading to fire.
-
Power must be cut off during maintenance to prevent the risk of electric shock.
-
Drain tank and air filter must be installed.
-
Do not switch on after power connected for 10 seconds.
-
If machine doesn’t work or have abnormal conditions, please, cut off power to prevent accidents; and close leakage circuit breaker and ask supplier to check and repair, or it may lead to fire because of electricity leakage and short circuit.
-
It must have a reliable grounding wire otherwise it may cause electric shock risk when unit failure or leakage.
-
Attention when installing:
-
Do not install when the machine is connected to the power.
-
It must be installed by a professional person.
-
If the installation is incorrect, it may cause electric shock and fire accident.
-
This appliance is not intended for use by people (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
If the cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified people in order to avoid a hazard.
For additional protection, the installation of a residual current device (RCD) having a rated residual operating current not exceeding 30mA is advisable in the electrical circuit supplying the bathroom. Ask your installer for advice. -
Environmental Protection
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist.
Check with your Local Authority or retailer for recycling advice.
Parts name and dimension drawing
Using the Unit
Stretch out both hands and insert them all the way in.
The unit starts to run automatically.
- Pull them out slowly, letting the air blow the water off.
- Pull them out completely.
Self-check indicator
When a malfunction or error occurs, the self-check indicator on the right side
will either light up or flash.
Turn off the power switch, wait about 40 seconds until all the indicators go
off, then turn on the power switch.
If the indicator still lights up or flashes, turn off the power, disconnect
the unit from the socket, and contact your dealer immediately.
Stick the usage label on the visible place (the front of the unit or the wall nearby}.
-
When using the unit
Turn on the power switch.- The power indicator lights up
- The lamp lights up.
- The cover of power supply is closed.
Routine Cleaning
Cleaning the Unit body
Before it gets obviously dirty
-
Clean the unit with a soft cloth.
If the unit gets very dirty, clean with a soft cloth dampened with neutral agent, then clean with a dry soft cloth. -
Remove the dirt from the sensor. (to prevent malfunction)
Note
- Only use neutral cleaning agents.
- Do not use thinner, acidic or alkaline toilet cleaners, or nylon brush. (Otherwise, they may damage the smoothness of surface) Only use alcohol to clean the hand-drying area. (Do not use alcohol anywhere else) Alcohol here means the alcohol used for disinfection (concentration below 83%).
- If chemical cloths used, please read their instructions first.
- Disinfecting agents will damage your unit.
WARNING
-
Before you clean the unit, turn off the power switch.
-
Do not splatter water on the unit
Caution -
Wear gloves when cleaning.
-
The antibacterial coating is effective when bacteria is exposed to the coated surfaces (See the shade areas on the figure)
-
The antibacterial coating becomes not effective when the surfaces get very dirty.
Draining and Cleaning the drain tank
Before it fills up (at least once a week)
- The water blown off the hands is called “drain water” .
- Empty the drain water at any moment, in order to prevent accumulated water from exceeding the full level.
- It will start smelling if the accumulated water remains in the tank for too long time.
Pull the drain tank out in the horizontal direction.
This ensures the drain water does not splatter out.
-
Open the cover and empty the water.
- Pull the cover up with your fingers in the direction of the arrow on top ‘ ~· of the cover, and then remove the cover completely.
-
Wash out the interior of the drain tank.
-
Close the water tank cover, and Re-attach it to the unit as original.
- Confirm the two locations are firmly inserted.
Add 200cc (around 1 cup) of water through the drain hole.
(to prevent it from getting clogged)
- Use the unit after confirming that the water tank is in place.
Cleaning the air filter
Around once a week
Remove the air filter
- Pull the air filter out by the handle.
- Cleaning the air filter
- Beat it lightly by hand or use a vacuum cleaner.
- If it is very dirty, wash it off with cold or warm water.
- Re-attach to the unit.
- insert it all the way in, until it stops.(lf it is not in place, the dirt or dust will enter the unit and shorten its service life.)
Note
- If you wash the air filter with water, and dry it as much as possible.
- Do not expose to the fire.
Troubleshooting electrical schematic
If you discover the following circumstance please inspect and action the following:
Electrical schematic
Precautions before installing
Do not install in the following types of location, otherwise this may cause malfunction:
- Locations where the temperature can exceed -10 °c or 40 °c.
- Locations where the unit may come into direct contact with water.
- Locations where the unit is under direct or strong sunlight
- Locations where there is a lot of condensation.
- Locations where corrosive, neutral, or reductive gases are present.
- Places lower than -20m or higher than 2000m above sea level
Installation location
-
Install somewhere the unit will be easy to use, as shown in the figure.
If the unit is installed too low, water may get on it when the floor is being cleaned. (The bottom of the unit must be at least 150 mm higher than the floor or any objects under it.) -
The left side of the unit must be at least 150 mm away from any walls, because the power switch is located on the left.
-
Ensure there are no mirrors or walls near the right side, as drops of water may splatter to the right when drying hands. (Recommended distance is at least 100 mm.)
-
Avoid locations where people or doors might bump into the unit.
-
Choose a completely flat surface on the wall to install the unit.
Installation Base
- If your space is limited and the condition of wall is unsatisfactory, you can purchase an installation base to install this unit.
Use a single-phase alternating rated voltage supply.(Do not be used with a
power supply exceeding rated voltage ±10%.)
Use a power cord which is between 2mm’ and 2.5mm’ thick. (Cords other than
2mm’ – 2.5mm’ single-core cords cannot be used.)
(A drop in voltage is possible if the power cord exceeds 11 m in length, so we
recommend using a 2.5mm2 cord.)
Wire the unit.
Embed the switchbox in the installation location (1 switch box no cover) and
wire the power cord (with the green and yellow combined is ground line).
- If no switchbox is used, the power cord will be pushed out, and prevent the unit from being installed firmly against the wall.
- If the wall is not concrete, reinforce it before installation.
Attach the installation panel to the wall using the 6 installation screws.
-
Remove the drain tank
-
Remove the front panel.
-
Remove the two screws.
-
Remove all the front panel chuckholes (3).
-
Remove the terminal box cover.
Remove the terminal box cover screw and pull the cover out towards you.
Pull the separate line power cord into the unit and secure inside.
This m achine has been supplied with
Power cor . If you want to change,
Please do according to the following steps.
Pull the power cord through the power cord hole on the rear of the unit, attach the rear side to the 2 hooks on the installation panel.
- The installation screws for the unit will not tighten completely if the hooks at the bottom of the installation panel are not in place.
Note: Ensure the unit is hooked on the installation panel, screws (at the low right), otherwise, this may cause the unit to drop and be in the danger of theft.
Wire the terminal box. (There is no polarity.)
- Strip the wire sheath as shown in the figure at right.
- Loosen the screws on the terminal box and connect the power cord to the terminal box.
- Remove the protective seal attached to the terminal box before connecting the ground wire.
- Tighten the screws on the terminal box and pull the power cord to make sure it is secured firmly.
- Bind the power cord using the clip to the right of the terminal box and fix it to its original location.
Attach the terminal box cover.
- Place the terminal box tabs into the holes and return the cover to its original position.securing it with the screw.
- Make sure the power cord and other wires are not pinched.
- The front panel cannot be attached if there are any wires in front of the terminal box cover.
Move the wires to the right of the terminal box cover.
-
Attach the front panel.
-
Insert the 3 front Panel chuckholes into the unit.
-
Replace the 2 screws that were removed.
-
Attach the drain tank.
-
Make sure the air filter is all the way in.
Test Run
Do not turn the unit power switch on with your hands inside.
If the self-check indicator in the display lights or is flashing, turn off the
power switch off, and turn the power back on when all the indicators go off
{after 40 seconds).
Packing List
- Unit · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 1
- Mountint plate · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 1
- 5mm Expansion pipe · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 6
- 5x25Self-tapping screw · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 6
- User Manual (include Packing List and Warranty Card)· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 1
- Method of use figure · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 1
- Roughing efficiency (air) filter……………………………………………….. 1
- Key………………………………………………………………………… 1
- HEPA ………………………………………………………………………. 1
7 Riverside Court, Don Road
Sheffield, S9 2TJ. UK.
Tel: +44 (0)114 3540047
Email: info@dryflow.co.uk
www.dryflow.co.uk
References