Dryflow EF0 EcoForce Intelligent Hand Dryers User Manual
- June 5, 2024
- Dryflow
Table of Contents
Dryflow EF0 EcoForce Intelligent Hand Dryers
Features
-
Control:
Designed with SCM control. The motor will cut off when operation exceeds 50s. -
Dry hands quickly:
Dry hands in 10s -12s -
Heat switch:
Can be set to cold or hot air using the heat switch. -
Anion generator:
The anion generator inside purifies the surrounding air. -
Fragrance holder:
An optional fragrance piece provides a fresh smell in the washroom as soon as the unit starts. -
Appearance:
Robust yet elegant.
Specifications
Power supply | 220V~50Hz |
---|---|
Sensing distance | 12 + 3cm |
Warm air temp. | 40℃ + 10℃ |
Air speed | 80m/s |
Motor speed | 25000rpm |
Motor power | 550W |
Heating power | 700W |
Overall unit power | 1250W |
Overall dimension | 210mmX182mmX270mm(LxWxH) |
Appearance | Chrome White epoxy |
Troubleshooting
Problem | Reason | Solution |
---|
Not working
| No power| Check the power
Sensing distance too short| Adjust the sensor distance
Sensor device is damaged| Contact the supplier
No warm air
| Heat switch is off| Switch on
Heater element fail| Contact the supplier
The sensor board cable is loose| Contact the supplier
Motor doesn’t work|
Motor is damaged
|
Contact the supplier
Notice:
- This appliance is not intended for use by persons (including c hildren) with reduced physical, sensory or mental capabilities, r lack of experience and knowledge, unless they have been g iven supervision or instruction concerning use of the appliance b y a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
- If the supply cord is damaged, it must be replaced by the m anufacturer, its service agent or similarly qualified persons in rder to avoid a hazard.
Wire drawing
Notice before installing
To ensure this product works correctly, please make sure of the following:
-
Please read the user manual and install instructions before installation.
-
Please check if the wall is flat, clean and clear of obstruction.
-
Please give the manual to the owners after installation.
-
Don’t place or install an object in the sensor detection area.
-
Don’t put reflective objects such as s tainless steel ne ar the sensor window of the hand dryer as it will activate the sensor.
Don’t place or install an object in the sensor detection area. -
Please install where the sensor cannot be activated by sun light.
Installation instructions
- Please fix the mounting template at the required position on the wall.
- Drill 4 holes as positioned on the mounting template. Put the raw plugs provided i n the drill holes.
- Loosen the screws on the cover using the Allen key and remove the cover.
- Align the holes of the back plate with the drilled holes and secure with the 4 screws.
- Replace the cover and secure using the Allen key.
Notice:
There must be more than 1.1m from the bottom of the hand dryer to the floor
when installed.
Usage instructions
Place your hands under the hand dryer to activate the airflow. The airflow will continue for 50s, unless the hands are removed from the sensor area before this time.
Adjustment of sensing distance
Remove the cover, and adjust the W1, turn clockwise to increase the distance,
and counter clockwise to reduce the distance.
Temperature control
You can adjust warm or cool air via an internal switch . When it is turned on,
it will produce warm air. When it is turned off, it will produce co ol air.
Components
1| Lens| 7| Cover for air
tunnel
| 13| Filter cover
---|---|---|---|---|---
2| Air outlet| 8| Heater device| 14| Anion generator
3| Heat switch
(pre-2017 models)
| 9| Cover for bottom part of motor| 15| Heating element wire
4| Inner hexagon
screw
| 10| Motor| 16| Control box
5| Cover| 11| Cover for upper part of motor| 17| Back plate
6| Sensor| 12| Filter pad| |
7 Riverside Court, Don Road Sheffield, S9 2TJ. UK.
Tel: +44 (0)114 3540047 Email:
info@dryflow.co.uk
www.dryflow.co.uk
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>