Package Contents: Chassis, AC Power Cord, Fourteen Retainer-plates, Installation Guide
The pictures are for demonstration purposes only. The actual product may differ in appearance from the depicted.

Installation

Step 1 : Install the Media Converters in the Chassis
Note:
It is recommended to use TP-Link media converters. Other vendors’ products may be incompatible.

  1. Tweak out the two screws on the media converter. Then install the retainer-plate (provided with the chassis) to the media converter using the screws removed from the media converter.tp-link MC1400 14-Slot Rackmount Chassis - Step 1
  2. Remove the front metal plate of the slot on the chassis, then carefully slide the media converter into the slot and lock it tightly with the locking knob.tp-link MC1400 14-Slot Rackmount Chassis - Step 2

Step 2: (Optional) Install the Redundant Power Supply Module
Remove the protective cover on the power supply module slot of the chassis.
Then gently push in the module and plug it solidly into the connector.tp-
link MC1400 14-Slot Rackmount Chassis - Step 3 Step 3: Mount the Chassis on the Rack
Note:

  1. The chassis supports EIA standard-sized, 19-inch racks.
  2. For security reasons, it is recommended to install the chassis as shown below.

Fasten the chassis to the rack with screws through the holes of the brackets on each side.tp-link MC1400 14-Slot Rackmount Chassis - Step
4 Step 4: Power On

  1. Electrically connect the Grounding Terminal on the rear panel of the chassis to ground via the ground cable.tp-link MC1400 14-Slot Rackmount Chassis - Step 5
  2. Connect the chassis to the AC outlet using the provided power cord.tp-link MC1400 14-Slot Rackmount Chassis - Step 6

Panel Layout

tp-link MC1400 14-Slot Rackmount Chassis - Panel
Layout Note:

  • An optional AC or DC power supply is available for installation in the optional power supply position.
  • The power source should comply with Electrical Energy Source Class 1 (ES1) of IEC 62368-1.

LED Explanation

Power
On: Power on
Off: Power off
FAN
On: The fans are working properly.
Off: The fans are working abnormally.

Specifications

Specifications

AC Power Supply| Input: 100–240 V ~ 50/60 Hz 1.8 A (Max)
Output: 12 V, 6.25 A (Max)
Ripple & Noise: < 180 mV (0˚C to 50˚C);
< 250 mV (-10˚C to 0˚C)
---|---
LED| MC1400: 9 V/0.6 A
FC1420:  5 V/0.6 A
Dimensions (W×D×H)| Power, FAN
Hot-swappable| Ye s
Overload Protection| Ye s
DC Power Output per Slot| 482 × 309 × 86 mm

Safety Information

  • Keep the device away from water, fire, humidity or hot environments.
  • Do not attempt to disassemble, repair, or modify the device. If you need service, please contact us.
  • Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.
  • The label is placed on the bottom surface of the product.
  • Place the device with its bottom surface downward.
  • The socket-outlet shall be installed near the equipment and shall be easily accessible.
  • Plug the product into the wall outlets with earthing connection through the power supply cord or plug.

In Denmark: Apparatets stikprop skal tilsluttes en stikkontakt med jord som giver forbindelse til stikproppens jord.
In Finland: Laite on liitettävä suojakoskettimilla varustettuun pistorasiaan
In Norway: Apparatet må tilkoples jordet stikkontakt
In Sweden: Apparaten skall anslutas till jordat uttag
Please read and follow the above safety information when operating the device. We cannot guarantee that no accidents or damage will occur due to improper use of the device. Please use this product with care and operate at your own risk.

FCC compliance information statement
Product Name: 14-Slot Rackmount Chassis
Model Number: MC1400/FC1420
Responsible party:
TP-Link USA Corporation
Address: 10 Mauchly, Irvine, CA 92618
Website: https://www.tp-link.com/us/
Tel: +1 626 333 0234
Fax: +1 909 527 6804
E-mail: sales.usa@tp-link.com
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
We, TP-Link USA Corporation, has determined that the equipment shown as above has been shown to comply with the applicable technical standards, FCC part 15. There is no unauthorized change is made in the equipment and the equipment is properly maintained and operated.
Issue Date: 2023/09/14

Industry Canada Statement
CAN ICES-3 (A)/NMB-3(A)

CE Mark Warning
This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

| Caution
Shock hazard
---|---
| Disconnect all power sources

Environmental and Physical Specifications

Operation Temperature| MC1400: 0˚C to 40˚C (32˚F to 104˚F)
FC1420: 0˚C to 50˚C (32˚F to 122˚F)
---|---
Storage Temperature| -40˚C to 70˚C (-40˚F to 158˚F)
Operation Humidity| 10% to 90% RH  non-condensing
Storage Humidity| 5% to 90% RH  non-condensing

EU Declaration of Conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC, 2011/65/EU and (EU)2015/863. The original EU declaration of conformity may be found at https://www.tp-link.com/en/ce.
UK Declaration of Conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of the Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016. The original UK Declaration of Conformity may be found at https://www .tp-link.com/support/ukca

Explanation of the symbols on the product label
Symbols may vary from products. The label is at the bottom of the product.

Symbol Explanation
Icon

Cl ass I I equipment
| Cl ass I I equipment with functional earthing
| Alternating current
| Direct current
| Po l a rity of d.c. power connector
| For indoor use only
| Dangerous voltage
| Cauti on, risk of e lectric shock
| Ene rgy efficiency Ma rking
| Protecti ve earth
| Ea rth
| Frame or chassis
| Functional earthing
| Cauti on, hot surface
| Cauti on
| Ope ra tor’s manual
| Stand-by
| ON/”OFF” (push-push)
| Fuse
| Fuse is used in neutral N
| RECYCLING
This product bears the selective sorting symbol for Waste electrical and electronic equipment (WEEE). This means that
this product must be handled pursuant to European directive 2012/19/EU in order to be recycled or dismantled to minimize its
impact on the environment.
User has the choice to give his product to a competent recycling organization or to the retailer when he buys a new electrical or
electronic equipment.
| Cauti on, avo id listening a t high vo l ume l evels for l ong periods
| D i sconnection, a ll power p lugs
m| Switch of mini-gap construction
| Switch of micro- gap construction (for US version)
Switch of micro-gap / micro-disconnection construction (for other versions except US)
| Switch without contact gap (Semiconductor switching device)