SOYAL AR-837-EA Graphic Display Multi-Function Proximity Controller Instruction Manual
- June 5, 2024
- SOYAL
Table of Contents
AR-837-EA Graphic Display Multi-Function Proximity Controller
Instruction Manual
Contents
AR-837-EA: Face recognition
-
Products
-
Terminal Cables
-
Tools
-
Optional
• Ethernet: DMOD-NETMA10
(TCP/IP Module included RJ45 Connector)
Or
DMOD-NETMA11
(TCP/IP Module with POE function)
• Any Wiegand Output Module (CN10)
• AR-MDL-721V (Voice Module)
• AR-321 L485-5V (TTY to RS-485 Converter)
Installation
Installation Method
- A-1. Surface Mounted: Use a screwdriver to screw the mounting plate to the wall.
- A-2. Embedded: To dig a hole for 128mmx109mm; and then, use a screwdriver to screw the mounting plate to the wall.
- Pull cable ends through the access hole in the mounting plate.
- Attach AR-837-EA to the mounting plate and install screws (supplied) into the holes at the bottom with the Allen key.
- Apply power. LED (green) will light up with one beep.
Dimension (mm)
| |
---|---|---
• Surface mounting hole(Front View)
• Flush-mounting hole(Front View)| • Surface mounting hole (Side view)| •
Flush-mounting hole (Side view)
Installation Guide
Surface / Flush-mounted Multifunctional Face & RFID Recognition Controller
Notice
- Tubing: The communication wires and power line should NOT be bound in the same conduit or tubing.
- Wire selection: Use AWG 22-24 Shielded Twist Pair to avoid star wiring, CAT 5 cable for TCP/IP connection
- Power supply: Don’t equip the reader and lock with the same power supply. The power for the reader may be unstable when the lock is activating, which may cause a malfunction in the reader.
The standard installation: The door relay and lock use the same power supply, and the reader should use another independent power supply.
Connector Table (1)
Cable: CN3
Wire Application | Wire | Color | Description |
---|---|---|---|
Anti-Tamper Switch | 1 | Red | N.C. |
2 | Orange | COM | |
3 | Yellow | N.O. |
Cable: CN4
Wire Application | Wire | Color ‘Description |
---|---|---|
Lock Relay | 1 | Blue White (N 0.)DC24V1Amp |
2 | Purple White (N.C.)DC24V1Amp | |
Lock Relay COM | 3 | White |
Door Contact | 4 | Orange |
Exit Switch | 5 | Purple |
Alarm Relay | 6 | Gray |
Power | 7 | Thick Red |
8 | Thick Black | DC OV |
Cable: CN6
Wire Application | Wire | Color | Description |
---|---|---|---|
RS-485 for Lift Controller | 1 | Thick Green | RS-485(B-) |
2 | Thick Blue | RS-485(A+) |
Cable: CN5
Wire Application | Wire | Color | Description |
---|---|---|---|
Beeper | 1 | Pink | Beeper Output 5V/100mA, Low |
LED | 2 | Yellow | Red LED Output 5V/20mA, Max |
3 | Brown | Green LED Output 5V/20mA, Max | |
Door Output | 4 | Blue White | Transistor Output Max. 12V/100mA (Open Collector |
Active Low)
Wiegand| 5| Thin Green| Wiegand DAT: 0 Input
6| Thin Blue| Wiegand DAT: 1 Input
WG Door Contact| 7| Orange| Negative Trigger Input
WG Exit Switch| 8| Purple| Negative Trigger Input
Cable: CN8
Wire Application | Wire | Color | Description |
---|---|---|---|
Reserved | 1 | Red | — |
Security trigger signal | 2 | Purple | Security trigger signal Output |
Arming | 3 | Red White | Arming Output |
Duress | 4 | Yellow White | Duress Output |
Cable: CN13
Wire Application | Wire | Color | Description |
---|---|---|---|
Door Bell | 1 | Black White | Transistor Output Max. 12V/100mA (Open Collector |
Active Low)
2| Black| DC OV
Cable: CN7
Wire Application | Wire | Color | Description |
---|---|---|---|
1 | — | — | |
2 | — | — | |
TCP/IP Output | 3 | Orange White | Net – TX+ |
4 | Orange | Net – TX- | |
5 | Green White | Net – RX+ | |
6 | Germ | Net – RX- | |
7 | — | — |
Cable: CN9
Wire Application | Wire | Color | Description |
---|
Voice Module
(*Required speaker
8Ω / 1.5W (Max.
2W)| 1| Black| DC OV
2| Yellow| TX
3| White| TE
| |
4| Orange| RX
5| Red| DC 5V
6| Blue|
Cable: CN10
Wire Application Wire | Color | Description |
---|---|---|
HID RF Module | 1 | Orange |
2 | Purple | ANT 2 |
3 | Black | DC OV |
4 | Red | DC 5V |
5 | Blue | Wiegand DAT: 1 Input |
6 | Green | Wiegand DAT: 0 Input |
7 | White | 1MM |
Wiring Diagram
Connect to Electric Bolt
Connect to Magnetic Lock
Connect to Electric Strike
Door Open Too Long Alarm Wiring Method (External Door Sensor)
Tamper-Switch Alarm Wiring Method
(Connect to Central Monitoring System through Modbus via Universal I/O Module)
Tamper-Switch Alarm Wiring Method
(WG Port Door Sensor Wiring Method)
※ The Wiring of Enable “Share Door Relay” ( Set up via the parameters setting Window of 701ServerSQL)
Strengthen security with AR-721RB
※ This wiring method is not eligible for the “Share Door Relay” function (set up via parameter setting of 701ServerSQL). If there is external wiring to the Wiegand reader, WG Port must enable Digital Relay Output to enable the “Share Door Relay” function.
Connect to Reader
(Connecting the external LED as a backlight requires a special firmware
update and WG Slave Mode will be disabled.)
※ The Wiring of Disable “Share Door Relay” ( Set up via the parameters setting Window of 701ServerSQL
AR-837-EA becomes WG mode
(28 000 )
-
When AR-837-EA becomes WG mode, it can be used with any controller.
-
Two AR-837-EA can be separately set as Master and WG Slave readers for Anti-pass back access in entry and exit.
※Using Rule :
Face Recognition for both entry and exit: Both AR-837-EA Master mode and AR-837-EA WG Slave mode must be stored all the same face data and real or visual card number. Card: Can pass WG message to the controller. -
When entering the Parameter Setting Window on 701Server, the device can be changed to WG Slave Mode by Enabling the “Ev5 WG out / Hv3 Lift out” Option.
Programming
A. Keyboard Lock/ Unlock
- Lock/ Unlock
Press and simultaneously lock the keyboard. Press simultaneously again to unlock.
B. Entering and Exiting Programming Mode
-
Entering
Input 123456 # or PPPPPP #
[e.g.] The Default Value= 123456. If already changed the Master Code= 876112, input *** 876112 # → Access programming mode P.S.If no instruction is entered within 30 sec.,** it will automatically leave the programming mode. -
Exiting Press the repeatedly 6 Quit or 7 Quit and Arming (Please refer to alarm/arming setting)
-
Changing the Master Code
Access programming mode → 5„ Tools 2paster Code → Input the 6-digit new master code → Succeeded
C. Initial setup
-
Language Setting
Access programming mode → 5 Tools → 1 Language → 0 EN → **** Succeeded → Initial system… -
Node ID of Reader Setting
Access programming mode — 3 Parameters[1] → 1 Node ID → Input New Node ID : 1-254 (default value:001) → Main Door Number : 0-255 —0 WG1 Door Number : 0-255-0 Show UID (0=No, 1=WG, 2=ABA, 3=HEX) → Enable DHCP(O:No, 1:En, 2=Exit) → Succeeded
Function Description of Front Panel & Indicator
-
The system will automatically exit Programming Mode when inactivating for 30 seconds.
-
LED status indicates the controller’s mode and status.
OK (green) – blinking constantly when operating in Programming Mode
– or flashing an existed card in card learn mode, it comes 2 beeps warning and LCD panel displays “Same Card: user address/card number”
Error (red) – invalid card with 2 beeps warning and LCD panel displays “Card Number Err!”
– or in anti-pass-back mode, when violates the access, it comes one beep warning, and the LCD panel displays “Anti-pass Error!” Arming (green) – arming on status Alarm (red)
– any abnormal condition occurs -
The keypad will be locked up for 30 sec. when incorrect pin code or master code is constantly entered.
-
Maximum error input of pin code and master code can be changed via the software 701Server (default: 5 times)
Networking: / and interactively flash between the Month and DAY.
[e.g.] 12/07←→12 07
Stand-alone: No flashing [e.g.] 12/07 (←Reference to picture)
Manu Tree
-
Add/ Delete
1. Add > Card ID
2. Add > RF Learn
3. Suspend > Address
4. Suspend > ID #
5. Delete > Address
6. Delete > ID #
7. Recover > Address
8. Recover > ID #
9. Antipass Group -
User Setting
1. Password
2. Access Mode
3. Extend Options
4. Single Floor
5. Multi Floor
6. Enroll Face
7. Delete Face -
Parameters[1]
1. Node ID
2. OnOff OpenZone
3. Door Relay Tm
4. Door Close Tm
5. Alarm Relay Tm
6. Alarm Delay Tm
7. Arming Delay Tm
8. Arming PWD -
Parameters[2]
1. Auto Relock
2. Egress(R.T.E)
3. Miscellaneous
4. Force Open
5. Close & Stop
6. Anti-pass-back
7. Duress Code
8. Password Mode
9. Factory Reset -
Tools
1. Language
2. Master Code
3. Master Range
4. Terminal RS-485
5. Ext.Comm CN11
6. Open Time Zone
7. Information
8. Clock Setting
9. Daily Alarm
0. UART Port CN9 -
Quit
-
Quit & Arming
D. Adding and Deleting Tag
※ User capacity: 16384 (00000~16383)
-
Adding Tag by Tag ID
Access programming mode → 1 Add/Delete → 1 Add -> Card ID → Input 5-digit user address → Input Site Code → Input Card Code -
Adding Tag by RF Learn Function
Access programming mode → 1 Add/Delete → 2 Add -> RF-Learn → Input 5-digit user address
→ Input Tag Units(pcs) → Close Tag into RF Area
※If the batch of tags is Sequential, input Tag Units(pcs) in the quantity of the tags and present the tag with the lowest number to the controller for adding all the tag data; otherwise, the tags must be presented to the controller individually -
Suspend User Address
Access programming mode → 1 Add/Delete → 2 Suspend -> Addr → Input Start address → Input End address -
Suspend Tag by Tag ID
Access programming mode → 1 Add/Delete → 4 Suspend -> ID # → Input Site Code → Input Card Code -
Recover User Address
Access programming mode → 1 Add/Delete → 7 Delete -> Addr → Input Start address → Input End address -
Recover Tag by Tag ID
Access programming mode → 1 Add/Delete → 8 Delete -> ID # → Input Site Code → Input Card Code -
Deleting User Address
Access programming mode → 1 Add/Delete → 5 Delete -> Addr → Input Start address → Input End address -
Deleting Tag by Tag ID
Access programming mode → 1 Add/Delete → 6 Delete -> ID # → Input Site Code → Input Card Code -
Setting up the access mode
Access programming mode → 2 User Setting → 2 Access Mode → Input User Address → 0: Invalid; 1: Card; 2: Card or PIN; 3: Card & PIN
E. PIN Code
Access programming mode → 2 User Setting → 1 Enroll Face → Input 5-digit user address → Input 4-digit PIN (0001~9999) → Succeeded Or via 701Client set it on the Users screen
F. Enroll/Delete Face
-
Adding
Access programming mode → 2 User Setting → 6 Delete Face → Key in 5-digit user address →Follow the instruction on LCD Screen to enroll face →Succeeded -
Deleting
Access programming mode → 2 User Setting → 7 Delete FP → Key in 5-digit user address → Succeeded P.S. If want to delete all users’ face data’ FP, key in 99999 #
G. Access Mode
Access programming mode → 2 User Setting
→ 2 Access Mode
→ Key in 5-digit user address (00000~08999)
→ 0: Invalid; 1:Card; 2: Card or PIN; 3: Card and PIN (837-EA: → Face
Identify: 0: Must; 1: Ignore )
→ Succeeded
Access Mode | Face Identify (837-EA Only) | Result (837-EA Only) |
---|---|---|
Hardware | 701Client | Hardware |
0:Invalid | 0: Must | Just Face |
Just card control | Invalid User | |
1: Ignore | Just Face |
Just card control
1:Card| 0: Must| Just Face
Just card control| Face+Card
1: Ignore| Just Face
Just card control| 1. Card Only
2. Face Only
2:Card or PIN| 0: Must| Just Face
Just card control| 1.Face+Card
2.Face+PIN
3.Card+Face+PIN
4.Card+Face+Card
5.PIN+Face+PIN
6.PIN+Face+Card
1: Ignore| Just Face
Just card control| 1. Card Only
2. PIN Only
3. Face Only
3:Card and PIN| 0: Must| Just Face
Just card control| Face+Card+PIN
1: Ignore| Just Face
Just card control| 1.Card+PIN
2.Face+PIN
H. Arming Password
Access programming mode → 3 Parameters[1] → 8 Arming PWD → Input 4-digit PIN (0001~9999; Default: 1234) → Succeeded Or via 701Server and set it on AR-829E screen
I. Arming Delay Time
Access programming mode → 3 Parameters[1] → 7 ArmingDelayTm → Enter armed sta. Delay time(Sec), Range:000~255; Armed pulse out-put time (10ms) , Range, 000~255 → Succeeded
J. Duress Code
Access programming mode → 4 Parameters[2] → 7 Duress Code → 4 sets
(select one) → Input 4-digit PIN (0001~9999) → Succeeded Or via 701Server to
set it on the AR- 829E-V5 screen
※Duress Code is only available in networking mode. It will substitute a
personal pin code and send the message of Duress to the computer as a warning
signal.
K. Terminal Port
Access programming mode → 5 Tools → 4 Terminal Port → 0:Lift ; 1:Host ; 2:LED ; 3:PRN (default value:1) → Baud Selection (default value:9600) → Succeeded
L. Setting up the alarm/arming
Conditions:
- Arming enabled
- Alarm system connected
Situations:
- The door is open over time: The door is open longer than door relay time plus door close time.
- Force open (Opened without a valid user card): Access by force or illegal procedure.
- The door position is abnormal: Happens when the power is off and then on again, besides, the reader was on arming before the power went off.
Enable/Disable the arming status:
※ [Use FP] can substitute for [Induct valid card].
M. Anti-pass-back
While connecting with AR-721-U, AR-737-H/U(WG mode), and AR-661-U for the anti-pass-back function, the access mode must be “Card” only.
-
Device enables
Access programming mode → 4 Parameters[2] → 6 Anti-pass-back → master controller select [1: Yes] → WG select [1: Yes] -
Card user enable
Access programming mode → 1 Add/ Delete → 9 Antipass Group → Input 5-digit starting user address → Input 5-digit ending user address → must select [1: Yes]
N. Lift control
[e.g.] Connect with AR-401-IO-0016R to control which floor the user will be able to access. (BAUD9600)
Setting Lift control
Access programming mode → 5 Tools → 4 Terminal Port → 0:Lift
Controller → Baud Selection 0: 9600
Access programming mode → 5 Tools → 5 Terminal Port → 1:Lift
Controller
(need to use AR-321L485-5V)
Single floor
Access programming mode → 2 User Setting → 4 Single Floor → Input
5-digit user address → Input single floor number: 1~64
Multi floors
Access programming mode →2 User Setting → 5 Multi Floor → Input 5-digit
user address → Select range: 1 or 2 or 3 or 4 → Input 16 digits multi
floors number [0:disable, 1: enable]
[e.g.] Set NO. 114, can use it through the 8 F and 16F:
Access programming mode → 2 User Setting → 5 Multi Floor → 114 → 1 →
0000000100000001
O. Alarm Clock (for Factory)
Access programming mode → 5 Tools → 9 Daily Alarm → Set (00~15) →
Set Start Tm (24 Hours); Set Effect Sec.
(Seconds as the bell time, Range:1~255) → Set Weekday (0:disable, 1:
enable) → Succeeded
Hardware installation
P. OpenZone
Access programming mode → 3 Parameters[1] → 2 OnOff OpenZone → Main Controller Auto Open Zone (0:disable, 1:enable) → Open Door mm. During Open Zone (0:No, 1:Yes) → WG1 Port Auto Open Zone(0:disable,1:enable) → Open Door Imm.During Open Zone(0:No, 1:Yes) → Succeeded
Q. Open TimeZone
Access programming mode → 5 Tools → 6 Open TimeZone → Set (00~15) → Time (24 Hours) → Main Port(0:disable,1:enable) ; WG Port(0:disable,1:enable) → Weekday(0:disable,1:enable) → Succeeded
Parameter Setting Menu
IP Address Config
Access programming mode → 3 Parameters[1] → 1 Node ID → Enter New Node ID → Main Door Number Range → WG1 Door Number Range → Show WG Message → Enable DHCP → please enter IP Address(IPV4) → please enter Net Mask(IPV4) → please enter Gatewa(IPV4) → Succeeded
Set card display mode
Access programming mode → 3 Parameters[1] → 9 PIN&UID format → User PIN Length → Card UID Length → Show UID → Succeeded
Face Enrollment Tips
-
The face should be close to the LCD screen, The size of the face image is half of the LCD that will be more easier to register successfully
-
Face Enrollment Procedure
Notes and Tips for Registration and Recognition of Wearing Face Mask Detection Mode
(—) When registering face data, the face mask could not be worn.
Collecting facial features
(=) Setting the security level of the face controller to [Level Low] will enable the face mask detection mode
(=) Emphasizing 3D model recognition and trying to collect more images around the eyes when registering face data.
Read User Manual Online (PDF format)