ADC 750W Wall Aneroids Sphygmomanometer Large Adult Installation Guide

June 23, 2024
ADC

ADC 750W Wall Aneroids Sphygmomanometer Large Adult

Tools Needed

  • Medium Phillips head screwdriver
  • Hammer
  • Drill with 3/16” drill bit

Directions

  1. Position manometer (with attached wall bracket) on wall at desired location and rotate gauge to right side to permit access to left-side mounting holes on bracket. Make pencil marks on wall through the mounting holes. Holding bracket firmly in place, rotate gauge to left side to permit access to right-side mounting holes. Make pencil marks on wall through the mounting holes. Recommended height is near the eye level of the intended users.
  2. At each of the four pencil marks, drill a 3/16” hole approximately 7/8” deep. Use a masonry type bit if drilling through ceramic tile.
  3. Gently tap the four screw anchors into the holes until they are flush with the wall.
  4. Position the manometer and bracket over the screw holes and screw bracket into wall first on one side, then the other (using the procedure outlined above to gain access to each of the four mounting holes). Take care not to over tighten screws.
  5. Attach eight-foot length of coiled tubing to air inlet at bottom of manometer. Wrap cuff around bulb and store in mounting bracket/storage compartment behind gauge.
    Note: If the mounting hardware supplied is not suitable for the application, select hardware of adequate size and type to secure the instrument firmly to the wall.
    Important: The instrument is designed to permit wall mounting without having to first remove the bracket from the instrument. If the instrument is removed from the bracket for mounting or service, we recommend applying removable Loctite to the bracket hardware to prevent the instrument from working loose. Loctite can be obtained from most hardware stores.

Assembly Instructions

  1. With base on its side connect upright outer pole to base using the long 6 mm hex screw and washer. Tighten with the large hex key provided. Tighten hardware as securely as possible. (To prevent loosening, periodically check that hardware remains securely tightened.) Reposition base upright. (Figure 1)

  2. Slide stainless steel inner pole inside outer pole with open end up. Make sure shock absorbing spring is inside the outer pole and tighten. (Figure 2)

  3. Attach metal basket to platform using two 3 mm hex screws. Tighten with small hex key provided.(Figure 3)

  4. Attach manometer bracket (with attached manometer) to platform using short 6 mm hex screw and washer. Tighten with large hex key. (Figure 4)

  5. Place assembly consisting of manometer, cuff storage basket and platform on top of stainless-steel inner pole, making sure the pole goes completely inside collar. Use tightening device and small hex key as shown.(Figure 5)

  6. Connect coiled tubing to gauge inlet. (Note: The coiled tubing may be difficult to connect; moisten with soapy water if necessary.) Refer to booklet titled Diagnostix Aneroid: Pocket, Palm, Clock Type (9350N-00) for instructions on operating the unit.

Schematic Parts List

Ref # Item # Description
1 972-101 Long 6 mm Hex Screw and Washer
2 972-080 Base
3A 972-106-1 Single Caster (3)
3B 972-106L-1 Single Locking Caster (2)
4 972-107 Outer Pole
5 972-108 Knob
6 972-109 Spring
6A 972-107A Gasket
7 972-110 Inner Pole
8 972-111 Tightening Device
9A 752-113 Manometer Bracket
9B 752-114 Short 6 mm Hex Screw and Washer
9C 752-115 Manometer Bracket Hardware
9D 752-119 Cuff Storage Basket
9E 752-117 Platform
9F 752-118 3 mm Hex Screw (2)
9G 752M-116 Large 6 mm Hex Key
9H 752M-117 Small 3 mm Hex Key