SOYAL AR-1500WF Electromagnetic Lock Instruction Manual

June 2, 2024
SOYAL

SOYAL AR-1500WF Electromagnetic Lock

SPECIFICATION

DESCRIPTION AR-1500WF

Door monitoring output
(reel sensor NO/NC)|
Input Voltage| 12 to 24 VDC
Current Draw| 12VDC – 500mA
24VDC – 250mA
Holding Force| 1300LBS
Dimensions( L x W x D ) Surface magnet Strike plate| 203 x 63 x 42 mm
185 x 61 x 16 mm
Material
Armature housing Strike plate| Stainless steel Steel

IN SWING DOOR ASSEMBLY

  1. Locate the desired position on the doorframe and attach the settlement plate to this location, using 8 screws included in the package.
  2. Insert 4 included screws through the pre-drilled holes on the lock and screws tightly to the settlement plate.
  3. Locate the proper position on the door, when closed, the magnetic lock will align correctly with the doorframe. Drill 5 holes at this location and attach the Z bracket to it. Important remark for tightening the Z bracket, tightening screws must be accompanied by a spring-washer to avoid slippery.
  4. Insert the 2 pins to the strike plate, place a pair of washers separated by rubber and between the strike plate. Insert the M8 flate head screw through the center of the strike plate, pass through the washers and tighten it to the Z bracket. Do not install the strike plate with Z bracket too tight. Leave some space to allow for best performance between the plate and lock.

ELECTRICAL INSTALLATION

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SOYAL User Manuals

Related Manuals