SOYAL AR-716-E16 Control Panel User Manual

October 30, 2023
SOYAL

SOYAL AR-716-E16 Control PanelSOYAL AR-716-E16 Control
Panel

Control Panel AR-716-E16 Parameter Setting

Set the connected access controller Node ID

Set the connected access controller Node ID

Step 1. Tick the connected access controller

  • AR-716-E16 built-in 2 WG Port connection. If wiring plan to wire WG Port 0 and WG Port 1, for access controller please start from node ID 3. This is because WG Port 0, 1 and Node ID 1, 2 share the same Door Number
  • Please refrain from ticking the connected Node ID if the controller is not connected.

Example 1: WG Port wired to WG reader

wiring to WG reader does not required to tick the box

Set the connected access controller Node ID

CH1 CH2 WG
Node ID 9 WG0
Node ID 10 WG1
Node ID 3 Node ID 11
Node ID 4
Node ID 5
Node ID 6
Node ID 7
Node ID 8

Example 2: WG Port does not wire to any WG reader

Set the connected access controller Node ID

CH1 CH2 WG
Node ID 1 Node ID 9
Node ID 2 Node ID 10
Node ID 3 Node ID 11
Node ID 4 Node ID 12
Node ID 5 Node ID 13
Node ID 6
Node ID 7
Node ID 8

Step 2. Door #: enter Door Number

Step 3. Relay Port: Available for WG Port 0*, RS485 CH1 Node ID 3, and RS485 CH2 Node ID 9. This setting is to enable reader wired under AR-716-E16 to use on-board relay output instead of the access controller own relay.

K1/K2 : the built-in relay of control panel to externally control the electric lock (if this function is selected, access controller’s connection to electronic lock is disabled, and the electric lock is connected to the K1/K2 contact). It is suitable for public door access such as Gate & Back Door access to provide safer connection.
For example: Gate installed Node ID 3 use K1 contact and Back Door installed Node ID 9 use K2 contact.

K3 : Public alarm

None : Use the access controller on-board relay to control the electric lock
WG Port 0 Relay Port option is only for dual door interlocking with CH2 Node ID 9 (Node ID 9 controller must be activated dual-door interlocking function by inputting command 44)

Reader Setting

Partial AR-716-E16 Parameter Setting is divided into ‘Main’ & ‘WG’

‘Main’ section is for AR-716-E16 as master controller and WG Port 0 reader

‘WG’ section is for WG Port 1 reader

Reader Setting

Customer Support

www.soyal.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals