BYD Battery-Box LV Flex Lite User Guide
- June 5, 2024
- BYD
Table of Contents
BYD Battery-Box LV Flex Lite User Guide
Make sure to always use the latest version of this service document, available
at: www.bydbatterybox.com
Important: The installation and all other kinds of works or measurements in combination with the Battery-Box Premium are only allowed by professional and qualified electricians.
This checklist is a shortened assistance for the Battery-Box and does notre place the original manual, which can be found on www.bydbatterybox.com / www.eft- systems.de / www.alpspower.com.au. Subject to technical modifications; no responsibility is accepted for the accuracy of this information. Attention: Improper handling can cause danger and damage.
GENERAL STEPS
Make sure to always use the latest version of this service document, available at: www.bydbatterybox.com
Please proceed first with the installation steps by:
No.
| Name|
Description
---|---|---
1.1| Configuration| Check if the configuration is correct. Refer to latest
“BYD BATTERY-BOX LV Flex Lite MINIMUM CONFIGURATION
LIST ”(V1.0 or above) available at:
www.bydbatterybox .com
Make sure the inverter is configured correctly
1.2| Correct external cabling|
- Communication to inverter
- Depending on the choice of inverter the cable between the BMU port and the inverter must be specially made. Please check the specifications in the installation manual.
- Recommended CAT5, CAT5e or higher;
- Check the cables and replace them if necessary
- Grounding
- Battery-Box connected directly to the ground-bus of the house.
- The battery must not be earthed via the inverter! Otherwise, communication problems are possible.
- Ethernet-Cable for Internet (strongly recommended! )
- DC-Ports – Make sure that + and – are properly connected.
- Correct parallel connection cabling if applicable
Notes about DC connection:
- Conductor cross-section: 16mm2
- Maximum cable length: 20m.
1.3| Latest Firmware| Always install / update the newest Firmware!
Note: If not stated otherwise, Wi-Fi password is BYDB-Box
1.4| App Configuration| To complete the commissioning, the configuration of
the battery via mobile device app “Be Connect 2.0” (BC APP) or PC app “Be
Connect Plus” (BCP) is mandatory!
1.5| Restart| After app configuration, please perform a proper restart of the
system by switching off the battery correctly (press LED Button on
BMU for 5 sec). Make sure all LEDs of the battery are completely off.
Figure 1 power off BMU
Then follow the correct switch on procedure (see step 1.6)
1.6| Switch On procedure| Correct switch on procedure is important for a
correct operation
- Turn on the switch between the inverter and battery if there is any;
- Switch on the battery system; (press LED Button on the LV FLEX Lite module address 1 for 3 seconds; LV FLEX Lite module address 1 is the one connecting directly with BMU).
- Switch on the inverter.
1.7| Checking the correct operation| The system runs properly if: -Inverter
displays battery SOC correctly -System charges / discharges
Note: If you cannot complete the commissioning, then turn off the battery
before you leave the site and make sure all LEDs are off to avoid a discharge
of the battery.
ERROR ANALYSIS
Please refer to the general steps before proceeding, see chapter 1.
BMU shows no reaction/ No LED
LED of BMU does not light up, although the battery is ON.
No.
| Name|
Description
---|---|---
2.1.1| Check correct cable port| Make sure that the correct data cable port
has been used at the BMU (“BMS” port. Do not mix with “inverter” or “Ethernet”
port).
2.1.2| Replace Comm Cable| Try a completely new communication cable between
battery and BMU.
Note: Sometimes it might be necessary to unplug the communication cable
and plug it again while batteries are switched on.
2.1.3| Voltage measurement| Battery voltage should be around 50V, see Section
3.1 for voltage measurement.
If yes: try another BMU (if available).
If no: check another cable or
Try another LV FLEX Lite if multiple batteries are installed in the system.
2.1.4| Only LED faulty?| In some rare cases, the LED of the BMU is faulty. To
check that: check if there is a Wi-Fi access point of the Battery-Box. If so,
only the external LED is inactive and a commissioning could still work.
2.1.5| Module Exclusion Method| Check if system works when bypassing the
suspected module.
2.1.6| BMU exchange| If problem remains, try another BMU, if available.
Some modules do not show any reaction / No LED on module
LEDs of some modules do not light up, although button on topmost module is pressed for 3 seconds.
No.
| Name|
Description
---|---|---
2.2.1| Comm cable| Try to unplug the comm cable between the first affected LV
Flex Lite module and the one above it, and plug it again. Or try a completely
new comm cable between the first affected LV Flex Lite module and the one
above it
2.2.2| Only LED faulty?| In some rare cases, the LED of the module is faulty.
To check that: use BC APP or BCP to check whether the BMS information of this
module could be detected.
2.2.3| Switch on the suspected module| Press the LED button for three seconds
to power one the suspected module. If the LED cannot be lighted up, the
battery module is faulty.
2.2.4| Voltage measurement| Check voltage of the affected module(s). See
Section 3.1. Voltage should be around 50V. If voltage is lower than 38V, it
might be unable to power on.
Try to charge it as soon as possible if a charger is available, or replace it.
2.2.5| Module Exclusion Method| Module Exclusion Method (see section 3.2):
Check if the system works when bypassing the suspected module. Remove it if
bypassing works.
Problem with the Firmware Update / App Configuration
The Battery Management consists of two components: the BMU and the BMS. The Firmware Update from BC APP and BCP will update the BMU, which will then update the BMS. The BMS update can take up to 30 minutes until the firmware is updated on the BMS.
No.
| Name|
Description
---|---|---
2.3.1| Correct app and Firmware| Make sure to have the latest BC APP (>2.1.0)
and Battery Firmware (download inside BC APP) on your mobile device before
connecting BC APP with the battery Wi-Fi.
If BC APP cannot be installed, or other general problems occur with BC APP:
-
Try with a different mobile device with version Android: 5.0 or above,
IOS: 11 or above. -
Try with BCP (section 2.9)
2.3.2| Wi-Fi cannot be found / Wi-Fi unstable| For BMU version V1.21 (or
above), the Battery Wi-Fi turns off 5 hours after the start of the Battery. To
reactivate the Wi-Fi, press the LED button about 1 second or restart the
system.
To reset the Wi-Fi module, press the LED button three times (each time around
one second) within 6 seconds.
If problem remains:
- remove the LAN cable during the configuration. Once the Battery has been configured correctly you can connect it again to the Internet.
- check whether other mobile devices are connected the same Wi- Fi
- try another mobile device
- Power on the system, wait for 5 minutes and try again.
2.3.3| App reports: “The battery system may be busy, please try again later”|
Battery-Box is busy (e.g. the battery could be updating the firmware). Please
wait 10 minutes and try again.
2.3.4| Proper restart| Note: Whenever the configuration via BC APP / BCP
is changed, a restart of the battery is necessary to make sure that all
changes come into effect.
- Switch off the battery (Press button on BMU for 5 seconds until all batteries switch off. Note: if the modules do not turn off then, something is wrong in the top LV Flex Lite module<>BMU connection.Replace comm cable and try again.)
- Turn on the Battery (button on topmost battery)
2.3.5| Close and restart BC APP| If BC APP does not react anymore after some
minutes loading during the update process, close (close the program
completely) and restart BC APP. Or try with BCP (section 2.9)
2.3.6| BMS Version not updated| BC APP will only update the BMU. The BMU will
update the BMS, which can take up to 30 minutes.
If the BMS Version is not updated after 30min with stable inverter
communication, follow the below Process:
- Update Firmware through BC APP again
- Restart the system
- Switch off the Inverter first, then switch off the battery second (Press LED for 5 seconds)
- Wait for 2 Minutes
- Turn on the Battery first, then turn on the inverter second
- Wait for 30 Minutes
- Check BMS Firmware Version again with App. If Version is still wrong, do the update process again (if possible with another mobile device).
- Note: if Voltage of Battery is not shown in BC APP, the update will not be transferred to BMS. Make sure the BMU recognizes BMS properly.
Incorrect output voltage / No BMS Data
No.
| Name|
Description
---|---|---
2.4.1| App Configuration and Firmware| Please check if BC APP configuration
was successful and the Firmware is the most recent one. If there are problems,
please refer to Section 2.3
Note: It is important to select the correct module quantity. The quantity
you need to select refers to the overall quantity of LV Flex Lite modules and
not to the quantity of towers. For example, if you have 2 towers connected in
parallel, and 4 modules in each tower, you need to select the module quantity
of “8” in the BC APP /BCP.
Note: Don`t forget to properly restart system after changing
configuration!
2.4.2| Proper restart| Note: Whenever the configuration via BC APP / BCP
is changed, a restart of the battery is necessary to make sure that all
changes come into effect.
- Turn off the Inverter
- Turn off the battery (Press button on BMU for 5 seconds until all batteries switch off. All LEDs should be off)
- Turn off the switch between battery and inverter(if available )
- Wait for 2 Minutes
- Turn on the switch between battery and inverter(if available )
- Turn on the Battery (button on battery connected to BMU) and then
- Turn on inverter second
2.4.3| BMU<>BMS Communication| Make sure that the comm cable is connected to
the right port of BMU (the one labeled as “BMS”). Replace comm cable between
BMU and battery.
2.4.4| Comm cable between modules| Try to unplug the comm cable between the
first affected LV Flex Lite module and the one above it, and plug it again.
Or try a completely new comm cable between the first affected LV Flex Lite
module and the one above it
2.4.5| Check terminal resistor| Make sure that the terminal resistor is
connected to the OUT port (Terminal resistor properties: 120Ω resistor between
pin 5 and 6)
If it was connected already, then please remove it and try without it to rule
out a faulty terminal resistor. Don’t forget to properly restart system
afterwards.
2.4.6| Module Exclusion Method| Refer to Section 3.2 to identify a potentially
faulty module.
2.4.7| Further checking| If problem remains:
- Upload logs with BC APP (section 2.10) or download all data with BCP ( section 2.9)
- Check the inverter
- Test another BMU, if available
Communication problem with Inverter
No.
| Name|
Description
---|---|---
2.5.1| Configuration| Check if the inverter is correctly selected when
configuration. Refer to latest “BYD BATTERY-BOX LV FLEX LITE MINIMUM
CONFIGURATION LIST” (V1.0 or above) available at:
www.bydbatterybox.com
Make sure the inverter is configured correctly
2.5.2| Inverter settings| Make sure to configure the battery correctly on the
inverter interface. Refer to inverter manual for details.
2.5.3| Comm cable| Confirm PIN / Cable Configuration for the specific inverter
model (see manual)
Replace the communication cable (min. CAT5!)
2.5.4| Check inverter status| Check whether the inverter has been successfully
powered on by the battery.
If the inverter has not been powered on, check whether the battery voltage is
within the inverter operating range or not. If the battery voltage is lower
than that, refer to section 3.3.
2.5.5| Further checking| If problem remains:
- Upload logs with BC APP (section 2.10) or download all data with BCP (section 2.9).
- Check the inverter
- Try by replacing the BMU, if available
SOC & charging logic
No.
| Name|
Description
---|---|---
2.6.1| SOC jumps| The SOC of an LFP battery cannot be measured. It is a
calculated value. In general, the state of charge (SOC) of a battery is
calculated using the voltage, but other factors such as temperature, current
flow and charging behavior also play a role. The calculation of the state of
charge is generally more precise if the battery regularly sees full cycles.
Every now and then an SOC correction / calibration might occur. That is
normal.
2.6.2| Charging & discharging logic| Charging & discharging is generally
controlled by the inverter.
2.6.3| Battery Logs / History Data| Download and provide all the historic
battery log files with BCP in order to identify the root cause. See section
2.9 for details.
You can also upload logs with BC APP. See section 2.10.
Unexpected shutdown
System has been successfully commissioned in the past and did run for some time. Later on an unexpected shutdown occurred.
No.
| Name|
Description
---|---|---
2.7.1| Inverter Communication| The battery only works with a compatible
external inverter. If for whatever reason the communication between battery
and inverter is lost, the battery will shut down itself within 30 minutes.
Therefore, check which one did shut down first (battery or inverter) and check
if inverter is properly detecting battery (e.g. showing correct SOC or
temperature).
If problem remains, check according to section 2.5.
2.7.2| Battery Logs /| Sporadic alarms are hard to detect as they only occur
sometimes. Therefore, it is very important to download and provide all the
| History Data| historic battery log files in order to identify the root
cause. See section 2.9 for details. You can also upload logs with BC APP. See
section 2.10.
2.7.3| Inverter Warning & Monitoring| Unexpected Shutdown can be caused by
overall system settings. Therefore, it is necessary to evaluate inverter data
as well.
- Which error message are shown in inverter portal?
BMU/BMS LED Event Code (EC)
A constant white LED refers to standby mode. White blinking means charge or
discharge. When the battery is initiating, the LED will flash white and blue
with an interval time of 0.5 seconds (normal during startup). When the LED
flashes blue with an interval time of 1 second it indicates an event code. We
start to count when the white LED begins to flash, then we count how many
times white and blue LED flashes. (Also refer to the manual!)
Figure 2 BMU and BMS LED Status
Example:
- 1 x white, 6 x blue → EC 106
- 1 x white, 11 x blue → EC 111
- 3 x white, 3 x blue → EC 303
Note: every LV Flex Lite Module has its own BMS. The Event Code of the BMS willtherefore be shown in the LED of the module.
Most Errors come from a faulty communication line, incorrect app configuration or missing restart after app-configuration. Please go in detail through: Section 1, 2.2 & 2.3
Note: if the system is not correctly configured with app, the event code (EC) might be misleading.
EC BMU
| EC BMS|
Measure
---|---|---
No LED| /| See section 2.1.
/| No LED| See section 2.2
Abnormal LED flickering| /| See section 2.1
Module Exclusion Method (see section 3.2): Check if the system works when
bypassing the suspected module
EC 101| /| Initialization Failure.
- Make sure BC APP-configuration has been completed correctly (especially module quantity!)
- Restart the system according to the manual. (Note: to properly shut down you need to press the button on the BMU for 5 seconds. Make sure to start the battery before starting the inverter!)
If the problem remains:
- Download all data with BCP (especially the historical data) (section 2.9), or upload logs with BC APP (section 2.10).
- replace BMU, if available
EC 102
EC 105
| /| Incorrect module quantity / Module not detected. See section 2.4
- Make sure app-configuration has been completed correctly (especially module quantity).
- Check terminal resistor. The terminal resistor (120Ω at pin 5+6) is responsible for a clean communication between BMS and BMU. In rare cases it can be damaged and can disturb the signal. In these rare cases it is recommended to remove the terminal resistor.
- 0replace communication cable between Battery and BMU
- Restart system according to manual. (Note: to properly shut down you need to press the button on BMU for 5 seconds. Make sure to start the battery before starting the inverter!)
- Module Exclusion Method (see section 3.2): Check if the system works when bypassing the suspected module
If problem remains:
- replace BMU, if available
- Download all data with BCP (especially the historical data) (section 2.9) Or upload logs with BC APP. See section 2.10.
EC 103| EC 108| PreCharge Fault.
- Check DC cabling and make sure that the Minimum Configuration is met.
- Restart system properly (see Step 2.4.2, section 2.4; If there is a fuse between battery and inverter, make sure to close the fuse first)
- Disconnect the battery system from the inverter and restart the battery system alone (battery isolated), to evaluate if the error is being caused externally (i.e. short circuit in inverter or mppt). If the Event Code remains, the error might be in the battery. If the Event Code has changed, there might be an error in the inverter side or DC cable connection.
- Module Exclusion Method (see section 3.2): Check if the system works when bypassing the suspected module.
If problem remains:
- Download all data with BCP (especially the historical and the cell data) (section 2.9), or upload logs with BC APP. See section 2.10.
- provide the SN and voltage of the faulty module (see checklist on last page)
EC 104| EC 101| Short circuit / DC reverse connection.
- Check DC cabling (is there any short circuit? Fuse between battery and inverter closed?)
- Disconnect the battery system from the inverter and restart the battery system alone (battery isolated), to evaluate if the error is being caused externally (i.e. short circuit in inverter or mppt). If the Event Code remains, the error might be in the battery. If the Event Code has changed, there might be an error in the inverter side.
- Module Exclusion Method (see section 3.2):Check if the system works when removing the suspected module
If problem remains:
- Download all data with BCP (especially the historical and cell data) (section 2.9), or upload logs with BC APP (section 2.10).
- provide the SN and voltage of all modules with the EC (see checklist at the last )
EC 104| EC 102 up to EC113
(All other than 101)
| One of the BMS (modules) reports an event message.
- Check the voltage of the batteries according to section 3.1 If problem remains:
- Download all data with BCP (especially the historical and the cell data) (section 2.9), or upload logs with BC APP (section 2.10).
- provide the SN and voltage of the faulty module (see checklist at the last )
EC 106| /| No communication with Inverter.
- Make sure the inverter is on, configured and working correctly.
- Check according to section 2.5
EC107| /| Model type error. Please check the configuration, make sure to choose the right model type.
Be Connect Plus (BCP)
Be Connect Plus is a Windows-PC tool. With BCP you can:
- read the battery information,
- configure the battery system
- update BMU & BMS firmware
- Export / download battery logs (From BMU and all BMS)
BCP is constantly being improved and updated. Make sure to use the latest
program version. You can download the latest version of the Tool on
www.bydbatterybox.com / www.eft-
systems.de /
www.alpspower.com.au.
For the service analysis, please download and provide the data / logs as described in the program instructions (see PDF manual inside of program ZIP archive).
Note: You need a computer with Windows that will be connected to the
battery Wi-Fi. Login as Installer to Be Connect Plus, the password is the same
as for Wi-Fi: BYDB-Box
Upload log data with BC APP
When you reach the Status interface, press the three dots on the top left
corner, and you will see the menu. Choose Upload Logs, and following the
instructions, then you can upload the logs to the BYD server.
Figure 4 BC APP screenshot
MEASUREMENT
Voltage measurement on pin 7 &8
Measure the voltage of pin 7 & 8 while the other side of the cable is connected to the IN port of the Battery and while the Battery is powered on. Voltage should be around 50V.
Note: Pin 7 and pin 8 are very close. It may cause short circuit if they
are measured directly! It is better to take a tool as shown in Figure 5.
Figure 5 voltage measurement on pin 7 &8
Identifying a faulty module / Module Exclusion Method
-
Normally a faulty module can be identified with the BCP, BC app or by the LED Code in the battery module. In this case, bypass the module with the Event Code, and commission the remaining system (if it still complies with the minimum configuration list) and check if it runs properly.
If the problem remains, please also bypass the module above the one with the Event Code. -
Otherwise, try the LV Flex Lite Modules one by one to identify a possibly faulty module.
If no LED on a module or more modules, check the one above the affected module first, and then the affected one. For example, in a LV Flex Lite system with 4 modules, If top modules have active LED but bottom modules dont, it indicates a connection issue between modules. If module 1&2 have LED, module 3&4 don
t have LED. Issue is in the connection between module 2 &3.Problem likely to be module 2 (less likely: module 3). -
Bypass the affected module and check whether problem disappears. If not, check the module below. To bypass module 2, just connect module 1 directly with module 3 as shown Figure 6.
Figure 6 bypass module 2
Note: The affected module often works without restrictions at the lowest module position of the tower.
Important: The module quantity must be adjusted in BC APP whenever the number of modules has been changed! Don`t forget to perform a proper restart after a new configuration!
Undervoltage
If the minimum cell voltage is less than 1.5 V, it is in undervoltage (check with BC APP or BCP).
- LV Flex Lite Modules with >45 V should be fine and you can go on to check other points according to this service guideline.
- If the module voltage is <40V but the single cell voltage is >1.5V, the battery needs to be charged as soon as possible while avoiding any further discharge. Therefore, shut down the system and search for the problem according to the guideline, while the battery is completely switched off. Also check on the inverter side why the force charge doesn`t work. Do not turn on the battery before making sure the inverter is able to charge the battery.
- If only one module is in undervoltage: remove that module and try commissioning without it (if the remaining modules still comply with the Compatible Inverter List). Otherwise, make sure to avoid further over discharge. (Turn off the system completely)
- If one, or all modules are in undervoltage: Contact BYD local service and make sure to avoid any further discharge of the battery (Turn off the system completely) When contacting the service, make sure to fill the service checklist completely and add the following information:
- Serial Numbers (of the BMU and all affected modules)
- Individual module voltages of all modules (related to Serial number)
- If possible: Upload logs with BC APP (section 2.10) or BCP (section 2.9) and screenshots showing the cell voltages – Initial Firmware (FW) Version of the Battery when the UV happened (BMU and BMS)
- Detailed description how and why the system reached Undervoltage if known. Information when the system was installed and commissioned and in which circumstance and when the undervoltage happened. If the battery was never running before: Why did it never work before, and what was the battery status when the battery was left (on / off / LED).
- Inverter Model, Serial Number and Inverter Logs.
SERVICE TASKS
Please go through the general steps beforehand.
BMU Replacement
Have you detected a faulty BMU?
After replacing the BMU, please do not forget to re-do the configuration and firmware-update with BC APP or BCP.
LV Flex Lite Module Replacement
After replacing a Module, please do not forget to re-do the configuration and firmware-update in BC APP. (Every module has its own BMS)
BYD Battery-Box LV Flex Lite Service Checklist – V1.0
Important: The installation and all other kinds of works or measurements in combination with the BYD Battery-Box are only allowed by professional and qualified electricians. Improper handling can cause danger and damage. This document does not replace the official BYD manuals and documents. No responsibility is accepted for the accuracy of the information.
GENERAL STEPS
Please carefully check all 7 „General Steps“ from page 3 and 4 of the Service Guideline and confirm this in the boxes below:
1.1 Configuration 1.4 App Configuration 1.7 Correct Operation
1.2 Correct external cabling 1.5 Restart
1.3 Latest Firmware 1.6 Switch on procedure
ERROR RELATED ANALYSIS
Please mark the error related Analysis from Chapter 2 and 3 of the Service Guideline that you checked, and collect all the information related to those Sections.
2.1 BMU shows no reaction / No LED
2.2 Some modules do not show any reaction / No LED on module
2.3 Problem with the Firmware Update / App Configuration
2.4 Incorrect output voltage / No BMS Data
2.5 Communication problem with Inverter
2.6 SOC& charging logic
2.7 Unexpected shutdown
2.8 BMU/BMS LED Event Code (EC)
2.9 Be Connect Plus (BCP)
2.10 Upload log data with BC APP
3.1 Voltage measurement on pin7&8
3.2 Identifying a faulty module / Module Exclusion Method
3.3 Undervoltage
SERVICE INFORMATION
Please fill all available information in below table. Some information like the Serial Number of the BMU is mandatory to receive service.
Service Ticket Number or System ID:
Installer / Delivery Address / Contact:
Company:
Contact Person:
Street / Nr.:
ZIP / City:
Phone:
Email:
System Information
Battery Configuration (X LV FLex Lite):
BMU Serial Number:
BMU Connected to Internet: Yes No .
Inverter Brand + Model:
Inverter Serial Number:
Commissioning Date:
BMU Firmware:
BMS Firmware:
Inverter Firmware:
Inverter Portal Name:
(State the system name. Provide access)
Service Information
BMU EventCode (EC):
Inverter Error Code:
BMS EventCode(s) and related Module Serial Number(s):
Was the battery charging / discharging before (was the system working normally
before?): Yes No .
Get Data of the Battery-Box with the Be Connect Plus (BCP) Programm (see
chapter 2.9):
Description of the Problem:
Please provide any additional information that is necessary or could help in the analysis of the service case (e.g. serial number of a wrong module, video of a special behaviour; pictures; app screenshots; module voltages… )
By contacting us you confirm, that a qualified person has done the necessary control and collected all available information above.
Service Contact:
BYD Company Limited
www.bydbatterybox.com
Global Sales: batteryboxgrp@byd.com
Global Service: bboxservice@byd.com
Battery-Box South Africa Service Partner
AFRIPLUS ENERGY GROUP (PTY) LTD
support@afriplusenergy.co.za
BYD LATAM Service
References
- ALPS POWER PTY LTD – BYD Battery-Box Australia Authorized Partner
- ALPS POWER PTY LTD – BYD Battery-Box Australia Authorized Partner
- BYD Battery-Box – BYD Battery-Box
- BYD Battery-Box – BYD Battery-Box
- Eft-Systems
- Eft-Systems
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>