BYD HVS 10.2 Battery-Box Premium User Guide
- June 6, 2024
- BYD
Table of Contents
BYD Battery-Box Premium
Quick Start Guide
LVL 15.4
BYD Europe B.V. V1.3
BYD Europe B.V.
Legal Provisions
All the information in this document is the property of BYD Europe B.V. No
part of this document could be reproduced in any way for business use.
Internal use is allowed.
BYD Europe B.V. makes no representations or warranties express or implied,
with respect to this document or any of the equipment and/or software it may
describe, including (with no limitation) any implied warranties of utility,
merchantability, or fitness for any particular purpose. All such
representations or warranties are expressly disclaimed. Neither BYD Europe
B.V. nor its distributors or dealers shall be liable for any indirect,
incidental, or consequential damages under any circumstances.
The exclusion of implied warranties may not apply in all cases under some
statutes, and thus the above exclusion may not apply.
This document cannot replace the locally applicable connection requirements,
standards, and directives. If these requirements, standards, and directives
are not followed during installation and commissioning, BYD won`t be liable
for that loss.
Specifications are subject to change without notice. Every effort has been
made to make this document complete, accurate, and up-to-date. However, BYD
Europe B.V. may need to make some improvements under certain circumstances
without advance notice. BYD Europe B.V. shall not be responsible for any loss
caused by this document, including, but not limited to omissions, errors,
typographical errors, arithmetical errors, or listing errors in this document.
All trademarks are recognized.
Limited Warranty
You can download the current Limited Warranty from the Internet on our
websites:
BYD Global Service, www.bydbatterybox.com,
BYD service partner in Europe, www.eft-systems.de,
BYD service partner in Australia,
www.alpspower.com.au.
BYD Europe B.V.
‘s-Gravelandseweg 256, 3125 BK, Schiedam, the Netherlands
Information on this Document
1.1. Validity
This document is valid for the Battery-Box Premium LVL15.4 from firmware
version 1.0.
1.2. Target Group
The instructions in this document may only be performed by qualified persons
who must have the following skills:
- Knowledge of how batteries work and are operated
- Knowledge of how an inverter works and is operated
- Training in dealing with the hazards associated with the installation and operation of electrical equipment and batteries
- Training in the installation and commissioning of electrical equipment
- Knowledge of, and adherence to the locally applicable connection requirements, standards, and directives
- Knowledge of, and adherence to this document and the associated system documentation, including all safety instructions
1.3. Content and Structure of this Document
This document contains safety information and instructions on installing,
connecting, and commissioning. Please finish reading this document before
taking any actions on the system.
The latest version of this document and the manual for installation,
commissioning, and operation are to be found in PDF format on our websites.
This document only contains brief information and may deviate from the real
system.
Safety
2.1. Intended Use
The system is for residential and small business use and works with a
photovoltaic system. It is a 48V Li-ion battery storage system, with a control
module on itself. It could be operated in either off-grid or on-grid mode with
compatible inverters.
The system could be connected to the Internet through network cable for
maintenance and software updates.
The system must only be used as stationary equipment.
The system is suitable for indoor use only.
The system must only be operated in connection with a compatible inverter. The
list (BYD Battery-Box Premium LVL Minimum Configuration List) of these
inverters could be read on our websites.
The system is not suitable for supplying life-sustaining medical devices.
Please ensure that no personal injury would lead due to the power outage of
the system.
Alterations to the BYD system, e.g., changes or modifications are not allowed
unless the written permission of BYD is achieved.
The enclosed document is an integral part of this system. Keep the
documentation in a convenient, dry place for future reference and observe all
instructions contained therein.
The type label should always be attached to the system.
2.2. IMPORTANT SAFETY INSTRUCTIONS
The system has been designed and tested in accordance with international
safety requirements.
However, in order to prevent personal injury and property damage and ensure
long-term operation of
the system, please do read this section carefully and observe all safety
information at all times.
2.2.1. Battery module leakage
If a battery module leaks electrolytes, contact with the leaking liquid or gas
should be avoided. The electrolyte is corrosive, and the contact may cause
skin irritation and chemical burns. If one is exposed to the leaked substance,
do these actions:
Inhalation: Evacuate the contaminated area and seek medical help
immediately.
Eye contact: Rinse eyes with flowing water for 15 minutes and seek
medical help immediately.
Skin contact: Wash the affected area thoroughly with soap and water and
seek medical help immediately.
Ingestion: Induce vomiting and seek medical help immediately.
2.2.2. Firefighting measures
The battery modules may catch fire when it is put into a fire. In case of a
fire, please make sure that an ABC or carbon dioxide extinguisher is nearby.
Water cannot be used to extinguish the fire.
Full protective clothing and self-contained breathing apparatus are required
for the firefighters to extinguish the fire.
2.2.3. Battery modules handling and storage guide
- The battery modules and their components should be protected from damage when transporting and handling.
- The weight of the system may cause injury risk, and please take the weight of the system into account while the system is transported and lifted carefully.
- Do not impact, pull, drag, or step on the battery modules.
- Do not insert unrelated objects into any part of the battery modules.
- Do not throw the battery module into a fire.
- Do not soak the battery modules in water or seawater.
- Do not expose to strong oxidizers.
- Do not short circuit the battery modules.
- The battery modules cannot be stored at high temperatures (more than 50 ℃).
- The battery modules cannot be stored directly under the sun.
- The battery modules cannot be stored in a high humidity environment.
- Use the battery modules only as directed.
- Do not use the battery modules if it is defective, or appears cracked, broken or otherwise damaged, or fails to operate.
- Do not attempt to open, disassemble, repair, tamper with, or modify the battery modules. The battery modules are not user-serviceable.
- Do not use cleaning solvents to clean the battery modules.
2.2.4. Surge protection
Overvoltages (e. g. in the event of a flash of lightning) can be further
conducted into the building and to other connected devices in the same network
via the network cables or other data cables if there is no surge protection.
Touching live parts and cables results in death or lethal injuries due to
electric shock.
Ensure that the system is integrated into the existing surge protection.
2.2.5. Safety information of the inverter manufacturer
Please read and observe all safety information of the inverter manufacturer.
Symbols on the System
Symbol
|
Explanation
---|---
| Observe the documents
Observe all documents supplied with the system.
| Grounding conductor
This symbol indicates the position for connecting a grounding conductor.
| WEEE designation
Do not dispose of the system together with the household waste but in
accordance with the disposal regulations for electronic waste applicable at
the installation site.
| CE marking
The system complies with the requirements of the applicable EU directives.
| Place it straight up, without inclination or upside down.
| Handle with care
| Keep it dry
| Keep the battery modules away from open flame or ignition sources.
| Beware of electrical voltage.
| Beware of a danger zone
This symbol indicates that the system must be additionally grounded if
additional grounding or equipotential bonding is required at the installation
site.
| Keep the battery modules away from children.
| Beware of hot surface
The system can get hot during operation.
| Do not short circuit.
EU Declaration of Conformity
Within the scope of the EU directives
- Low Voltage Directive 2014/35/EU (29.3.2014 L 96/357-374) (LVD)
- Radio Equipment Directive 2014/53/EU (22.5.2014 L 153/62) (RED)
BYD Europe B.V. confirms herewith that the systems described in this document
are in compliance with the fundamental requirements and other relevant
provisions of the abovementioned directives.
The entire EU Declaration of Conformity can be found on our websites.
Technical Parameters
Number of Modules | 2 |
---|---|
Usable Energy [1] | 15.36 kWh |
Max Cont. Output Current [2] | 250 A |
Peak Output [2] | 375 A, 5s |
Dimensions (H/W/D) | 500 x 575 x 650 mm |
Weight | 164 kg |
Nominal Voltage | 51.2 V |
Operating Voltage | 40- 57.6 V |
Operating Temperature | -10 °C to +50°C |
Communication | CAN/RS485 |
Enclosure Protection Rating | IP20 |
Round-trip Efficiency | ≥95% |
Scalability | Max. 64 in Parallel (983 kWh) |
Certification | IEC62619/ CE / CEC / UN38.3 |
Application | ON Grid / ON Grid + Backup / OFF Grid |
Warranty [3] | 10 years |
Compatible Inverters | Refer to BYD Battery-Box Premium LVL Minimum |
Configuration List
Battery Designation| IFpP/59/417/150/8S/M/-20+50/90
[1] Test conditions: 100% DOD, 0.2C charge & discharge at + 25 ° C. The
battery system Usable Energy may vary with different inverter brands.
[2] Charge/discharge derating will occur between -10 °C and +5 °C.
[3] Refer to BYD Battery-Box Premium Limited Warranty Letter.
Instructions
1. Scope of delivery
cc|
Designation
---|---
B1| Battery module 1
B2| Battery module 2
C| Power cable L2
D| Power cable L3
E| Screw M6×16
F| Screw M10×16
G| Screw M5×14
H| Network cable
I| Grommets (small size)
J| Bonding strip
K| Alignment pins
L| Plastic Bolts
M| Communication cable
N| Grommets (big size)
O| Quick Start Guide, Minimum Configuration List
Needed tools
Name | Reference |
---|---|
Electric Screwdriver | |
Diagonal Pliers | |
Torque Wrench | ![BYD HVS 10.2 Battery-Box Premium - |
Instructions5](https://manuals.plus/wp-content/uploads/2021/11/BYD-HVS-10.2
-Battery-Box-Premium-Instructions5.png)
Screwdrivers|
2. Installation location
3. Installation
3.1 Single system
3.2 Single stacks (Maximum two systems could be in one stack.)
3.3 Multiple stacks
4. Connection
Inverterport of BMU assignment
| BMU| SMA| STUDER| VICTRON|
SELECTRONIC
---|---|---|---|---|---
CAN H| 4| 4| 4| 7| 1
CAN L| 5| 5| 5| 8| 2
4.2 Single stack connection
4.3 Multiple stacks
4.4 Install the front covers back
5. Switch on the system(s)
6. Configuration
7. Switch off the system(s)
LED status
Flashing white and blue alternatively| | BMU and Battery-Box are
initiated.
---|---|---
Flashing white slowly| | Idle (Battery-Box is neither
charging nor discharging).
Flashing white slowly| | Battery-Box is charging.
Flashing white quickly| | Battery-Box is discharging.
Flashing white and glowing blue| | Battery-Box is discharging,
and the SOC of Battery-Box is below 15%.
Flashing white and blue| | An error has occurred.
Contact
BYD Global Service
Mailbox: bboxservice@byd.com
Telephone: +86 755 89888888-47175
Address: No.3009,BYD Road,
Pingshan,Shenzhen,518118,P.R.China
Website: www.bydbatterybox.com| Social
media link:
https://www.facebook.com/BatteryBoxBYD/
https://twitter.com/BYD_BatteryBox
https://www.linkedin.com/company/byd-battery-box
---|---
USA
EFT USA
Mailbox: USservice@eft-systems.de
Telephone: +1(833) 338-8721
Website: www.eft-systems.de/us| Australia
Alps Power Pty Ltd
Mailbox: service@alpspower.com.au
Telephone: +61 2 8005 6688
Address: 14/47-51 Lorraine St
Peakhurst NSW 221
Website: www.alpspower.com.au
Europe
EFT-Systems GmbH
Mailbox: service@eft-systems.de
Telephone: +49 9352 8523999
+44 (0) 2037695998(UK)
+34 91 060 22 67(ES)
+39 02 873683(IT)
Address: Bruchtannenstraße 28,
63801 Kleinostheim, Germany
Website: www.eft-systems.de| South Africa
SOLARVILLAGE(PTY)LTD
Mailbox: support@afriplusenergy.co.za
Telephone: + 27 83 3755 486
Address: UNIT 45 DENNEKAMP, SAILSBURY ROAD, KENILWORTH,
CAPE TOWN, WESTERN CAPE,7708
References
- ALPS POWER PTY LTD – BYD Battery-Box Australia Authorized Partner
- BYD Battery-Box – BYD Battery-Box
- Eft-Systems
- Eft-Systems
- BYD Battery-Box – BYD Battery-Box
- Eft-Systems
Read User Manual Online (PDF format)