ECLIPSE ES Series Ratio Regulators Owner’s Manual

September 27, 2024
ECLIPSE

ES Series Ratio Regulators

“`html

Specifications

  • Product Name: Eclipse Ratio Regulators ES Series
  • Version: 1
  • Website: https://www.add-furnace.com/
  • Contact: 02-888-3472
  • Email: add028883472@gmail.com

Product Description

The Eclipse Ratio Regulators ES Series is designed to regulate
ratios in specific applications. It is a precision-engineered
product that ensures accurate and efficient control over gas ratios
for optimal performance.

Usage Instructions

Safety Precautions

Before using the Eclipse Ratio Regulators ES Series, please read
the safety instructions provided in the manual. Always follow
safety guidelines to prevent personal injury or damage to the
product.

Installation

1. Select a suitable location for installing the regulator,
ensuring proper ventilation and accessibility.

2. Connect the regulator to the gas supply lines following the
provided installation diagram.

Operation

1. Turn on the regulator using the designated power switch.

2. Adjust the ratio settings as per your specific requirements
using the control knobs.

Maintenance

Regularly inspect the regulator for any signs of wear or damage.
Clean the regulator as recommended in the manual to ensure
consistent performance.

FAQ

Q: Can I adjust the gas ratios manually?

A: Yes, you can adjust the gas ratios manually using the control
knobs provided on the regulator.

Q: How often should I perform maintenance on the

regulator?

A: It is recommended to perform maintenance on the regulator at
least once every six months to ensure optimal functionality.

“`

44 . 70 . . 10170. website: https://www.add-furnace.com/ : 02-888-3472 Line ID: @add11 e-mail: add028883472@gmail.com
Eclipse Ratio Regulators
ES Series
Version 1

44 . 70 . . 10170. website: https://www.add-furnace.com/ : 02-888-3472
Line ID: @add11 e-mail: add028883472@gmail.com

Copyright
Copyright 1997 by Eclipse, Inc. All rights reserved worldwide. This publication is protected by federal regulation and shall not be copied, distributed, transmitted, transcribed or translated into any human or computer language, in any form or by any means, to any third parties, without the express written consent of Eclipse, Inc.
Disclaimer Notice
In accordance with the manufacture’s policy of continual product improvement, the product presented in this brochure is subject to change without notice or obligation.
The material in this manual is believed adequate for the intended use of the product. If the product is used for purposes other than those specified herein, confirmation of validity and suitability must be obtained. Eclipse warrants that the product itself does not infringe upon any United States patents. No further warranty is expressed or implied.
Liability and Warranty
We have made every effort to make this manual as accurate and complete as possible. Should you find errors or omissions, please bring them to our attention so that we may correct them. In this way we hope to improve our product documentation for the benefit of our customers. Please send your corrections and comments to our Marketing Communications Manager.

It must be understood that Eclipse’s liability for its product, whether due to breach of warranty, negligence, strict liability, or otherwise is limited to the furnishing of replacement parts and Eclipse will not be liable for any other injury, loss, damage or expenses, whether direct or consequential, including but not limited to loss of use, income, or damage to material arising in connection with the sale, installation, use of, inability to use, or the repair or replacement of Eclipse’s products.
Any operation expressly prohibited in this manual, any adjustment, or assembly procedures not recommended or authorized in these instructions shall void the warranty.
Document Conventions
There are several special symbols in this document. You must know their meaning and importance.
The explanation of these symbols follows below. Please read it thoroughly.
How To Get Help
If you need help, contact your local Eclipse representative. You can also contact Eclipse at:
1665 Elmwood Rd. Rockford, Illinois 61103 U.S.A.
Phone: 815-877-3031 Fax: 815-877-3336
http://www.eclipsenet.com

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

WARNING

Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION NOTICE NOTE

Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
Is used to address practices not related to personal injury.
Indicates an important part of text. Read thoroughly.

2

Eclipse Ratio Regulator, V1, Instruction Manual 742, 5/1/2009

44 . 70 . . 10170. website: https://www.add-furnace.com/ : 02-888-3472 Line ID: @add11 e-mail: add028883472@gmail.com
Table of Contents
Introduction ………………………………………………………………………………………………………………..4 Product Description …………………………………………………………………………………………………4
Safety …………………………………………………………………………………………………………………………5 Safety Warnings ……………………………………………………………………………………………………..5 Capabilities …………………………………………………………………………………………………………….5 Operator Training ……………………………………………………………………………………………………5 Replacement Parts ………………………………………………………………………………………………….5
Specifications …………………………………………………………………………………………………………….. 6 Compatability/Temperature Specifications………………………………………………………………….6 Model Specifications…………………………………………………………………………………………………6 Flow vs Pressure Drop …………………………………………………………………………………………….6 Dimensions …………………………………………………………………………………………………………….7
Design & Installation……………………………………………………………………………………………………9 General Information………………………………………………………………………………………………….9 Ratio Regulator/Pipe Connections …………………………………………………………………………….9 Gas Bias Adjustment ……………………………………………………………………………………………….10

Eclipse Ratio Regulator, V1, Instruction Manual 742, 5/1/2009

3

44 . 70 . . 10170. website: https://www.add-furnace.com/ : 02-888-3472
Line ID: @add11 e-mail: add028883472@gmail.com

Introduction

1

Product Description

Product Features

The ES-Series Ratio Regulators are used in applications where gas to air proportional flow is required. The gas flow is controlled as a function of the air pressure through a loading line which connects into the top of the regulator. As the system air pressure increases, it forces the ratio regulator valve to open causing the outlet pressure to increase until the two pressures balance. As the load line pressure increases, the ratio of the outlet pressure to the load line pressure will be slightly less than 1:1.
The ratio regulators have a bias adjustment for varying the gas flow when setting the burner at low fire. It can be used to increase or decrease the gas flow resulting in gas rich or lean combustion. The adjustment is restricted in the gas rich direction therefore limiting the gas flow at zero air pressure.
WARNING
The ratio regulators are control valves only and cannot be used as gas shut- off valves.

The ratio regulators are designed to optimize performance as ambient temperature and inlet pressure vary. Features include:
· UL recognized and CE approved for natural gas, propane, and butane.
· Valve seat design for consistent low fire repeatability.
· Balanced double diaphragm design allows regulator to operate over a wide range of inlet pressures while minimally affecting outlet pressure.
· Rugged die cast aluminum housing. · Corrosion resistant internal components. · Synthetic rubber diaphragms for excellent low
temperature performance.
· Inlet pressure tap with connector (1-1/2″, 2″ & 3″ NPT (Rp) models only).
Audience
This manual has been written for people who are already familiar with all aspects of a combustion system and its add-on components, also referred to as “the burner system”.

The audience is expected to have had experience with the ratio regulator component of a burner system.
Purpose
The purpose of this manual is to make sure that the ratio regulator component of a burner system is used in a safe, effective and trouble free manner.

Figure 1.1. Ratio Regulators
4

Eclipse Ratio Regulator, V1, Instruction Manual 742, 5/1/2009

Safety

44 . 70 . . 10170. website: https://www.add-furnace.com/ : 02-888-3472 Line ID: @add11 e-mail: add028883472@gmail.com
2

Important notices about safe ratio regulator operation will be found in this section. Read this entire manual before attempting to start the system. If any part of the information in this manual is not understood, contact Eclipse before continuing
Safety Warnings
DANGER
Do not bypass any safety feature. Fires and explosions can be caused.
Never try to use a ratio regulator that shows signs of damage or appears to be malfunctioning.

Capabilities
Adjustment, maintenance and troubleshooting of the mechanical parts of this system should be done by qualified personnel with good mechanical aptitude and experience with combustion equipment.
Operator Training
The best safety precaution is an alert and competent operator. Thoroughly instruct operators so they demonstrate an understanding of the equipment and its operation.
Replacement Parts
Order replacement ratio regulators from Eclipse only.

NOTICE
This manual gives information for the use of these ratio regulators within their specific design purpose. Do not deviate from any instructions or application limits in this manual without written advice from Eclipse.

Eclipse Ratio Regulator, V1, Instruction Manual 742, 5/1/2009

5

44 . 70 . . 10170. website: https://www.add-furnace.com/ : 02-888-3472
Line ID: @add11 e-mail: add028883472@gmail.com

Specifications

3

Compatibility/Temperature Specifications

Table 3.1

Compatible Gases
Natural Manufactured
Mixed Vaporized Liquified Petroleum
LP Gas-Air Mixture

Ambient Temperature Range
-40°F to 205°F (-40°C to 96.1°C)

CAUTION

Below 32°F (0°C), the gas must be free of water vapor which could condense and freeze within the
valve.

Model Specifications

Table 3.2

Model Part No.

Pipe Thread

Maximum Inlet Pressure1

ES365 19997 3/4″ NPT

1.0 psi

ES365M 19998

Rp 3/4

69.2 mbar

ES366 15939 1″ NPT

1.0 psi

ES366M 19999

Rp 1

69.2 mbar

ES363 20312 1-1/2″ NPT

5.0 psi

ES363M 20311

Rp 1-1/2

346.2 mbar

ES368 10315 2″ NPT

5.0 psi

ES368M 19990

Rp 2

346.2 mbar

ES369 10316 3″ NPT

5.0 psi

ES369M 19989

Rp 3

346.2 mbar

Capacity2

1,245 scfh 1,380 scfh 6,350 scfh 11,600 scfh 26,000 scfh

35.27 Nm3/hr 39.09 Nm3/hr 179.9 Nm3/hr 328.6 Nm3/hr 736.5 Nm3/hr

1 Gas inlet pressure must be greater than the total of the outlet pressure plus the pressure drop across the regulator at the required flow.

2 Capacity for natural gas (0.60 sg). When using propane or butane, divide capacity by conversion factors listed in Table 3.3.

6

Eclipse Ratio Regulator, V1, Instruction Manual 742, 5/1/2009

P mbar P “wc

10.0

4.0

44 . 70 . . 10170. website: https://www.add-furnace.com/ : 02-888-3472
Line ID: @add11 e-mail: add028883472@gmail.com

8.75 3.5

7.5

3.0

6.25

2.5

Model ES365 & ES365M Model ES366 & ES366M

5.0

2.0

3.75

1.5

2.5

1.0

1.25

0.5

0.0 0.0 0 200

400

600

800 1000 1200 1400 1600

Capacity, scfh

0

5.66 11.33 16.99 22.66 28.32 33.99 39.66 45.32

Capacity, Nm³/hr

Figure 3.1. Flow vs Pressure Drop, 3/4″ & 1” NPT (Rp) Models

87.5 35

75 30

62.5 25

50 20

37.5 15

25 10

12.5

5

Model ES363, ES363M Model ES368, ES368M Model ES369, ES369M

0

00

5 , 000

10,000

15,000 20,000

Capacity, scfh

25,000

30,000

0

141.6

283.3

424.9

566.5

708.2

849.8

Capacity, Nm3/hr

P mbar P “w.c.

Figure 3.2. Flow vs Pressure Drop, 1-1/2″, 2″ & 3″ NPT (Rp) Models

NOTE: Above graphs are for natural gas (0.60 s.q.). For propane or butane, multiply the gas flow by the factors listed below, to calculate the equivalent natural gas flow, then find the pressure drop from the previous graphs.

Table 3.3 Conversion Factors

Gas

Conversion Factor

Propane (1.5 s.g.)

1.58

Butane (2.0 s.q.)

1.82

Example: Find the pressure drop created by 15,000 scfh of propane through an ES369 ratio regulator.
1. Convert propane to the equivalent natural gas flow: 15,000 x 1.58 = 23,700 scfh
2. Plot the point where 23,700 scfh crosses the ES369 curve on the above graph.
3. Translate the intersection point back to the pressure drop axis.

4. The pressure drop at 23,700 scfh natural gas, equivalent to 15,000 scfh propane, is approximately 23.5″ w.c.

Eclipse Ratio Regulator, V1, Instruction Manual 742, 5/1/2009

7

3-7/8 (98.4) 1-1/2 (38.1)
5-11/16 (144.5)

44 . 70 . . 10170. website: https://www.add-furnace.com/ : 02-888-3472
Line ID: @add11 e-mail: add028883472@gmail.com

1/8″ NPT Load Line
2-3/8 (60.3)

4-7/8 (123.8)

Outlet End View

Swing Radius

Inlet ES365(M) 3/4″ NPT (Rp 3/4)
ES366(M) 1″ NPT (Rp 1)

4 (101.6)

Outlet ES365(M) 3/4″ NPT (Rp 3/4) ES366(M) 1″ NPT (Rp 1)

Figure 3.3. Dimensions in inches (mm), Models ES365 (M) & ES366 (M)

B Dia. D

F Load Line

Outlet End View

Swing Radius
A E

Inlet

Inlet Pressure Tap1

C

Outlet

1 1/4″ taper pipe plug on ES363(M) and ES368(M). No tap this side on ES369(M). 2 1/8″ taper test tap connector, 0.34″ OD (8.6 mm) for slip-on hose.

Inlet Test Tap Connector2

Model ES363 ES363M ES368 ES368M ES369 ES369M

Figure 3.4. Dimensions in inches (mm), Models ES363 (M), ES368 (M) & ES369 (M)

Swing Radius 6-3/16″
157.1 mm 9-3/16″
233.4 mm 13-1/4″
336.6 mm

Inlet/Outlet 1-1/2″ NPT
Rp 1-1/2 2″ NPT
Rp 2 3″ NPT
Rp 3

Table 3.4

A

B

9″

7″

228.6 mm 177.8 mm

11-1/4″ 9-1/8″

285.7 mm 231.7 mm

16-1/16″ 13-7/16″

407.9 mm 341.3 mm

C

D

E

5-1/2″

2-3/8″

3-3/4″

139.7 mm 60.3 mm 92.2 mm

7-5/8″

3-1/8″ 4-5/16″

193.6 mm 79.3 mm 109.5 mm

10-3/8″ 4-7/8″

6-1/8″

263.5 mm 123.8 mm 155.5 mm

F 1/2″ NPT
Rp 1/2 3/4″ NPT
Rp 3/4 3/4” NPT
Rp 3/4

8

Eclipse Ratio Regulator, V1, Instruction Manual 742, 5/1/2009

44 . 70 . . 10170. website: https://www.add-furnace.com/ : 02-888-3472 Line ID: @add11 e-mail: add028883472@gmail.com
Design & Installation 4

Design
To select the ratio regulator best suited for a combustion system, several parameters need to be considered. The following steps identify those items that need to be considered when selecting a ratio regulator.
Ratio Regulator selection based on flow:
· Define the maximum gas flow required for the system.
· Identify the ratio regulator for that flow based on the capacities listed in Table 3.2 of the “Specifications” section.
Minimum inlet pressure calculation:
· Define the pressure drop through the ratio regulator based on the Flow vs. Pressure Drop curves (Figures 3.1 and 3.2) and conversion factors listed in the “Specifications” section.
· Calculate the pressure losses through components mounted between the ratio regulator and the burner.
· Define the gas pressure required at the burner. · Calculate the minimum inlet pressure to ratio
regulator by taking 125% of the sum between the ratio regulator drop, component drops and burner pressure. · Verify that the inlet pressure is within the ratio regulator limit. If not, make the necessary changes to the ratio regulator or the upstream pressure control.
WARNING
Shut off gas supply before installing or removing the ratio regulator

General Installation Information
· Gas flow through the ratio regulator must be in the direction of the arrow on the body.
· Make sure the gas is compatible per Table 3.1. · Ambient temperature at the valve location must
remain between 40°F and 205°F (-40°C and 96.1°C). · The ratio regulator must be mounted with the spring tower in the vertical upright position. · Allow clearance above the ratio regulator to allow access to the bias adjustment. · Pipe ends are to be free of foreign material (excluding pipe dope) before connecting into the ratio regulator body. · Do not use the ratio regulator to support adjacent piping.
Regulator/Pipe Connections
1. Remove the protective caps from the ends of the ratio regulator.
2. Apply a moderate amount of pipe dope to the male pipe threads only.
NOTE: Excessive pipe dope could contaminate the valve set thus affecting pressure regulation.
CAUTION
Regulator must be installed with spring tower pointing upward, with flow in the direction of the cast arrow on regulator body.
3. Install the ratio regulator with the flow in the direction of the flow arrow on the body.

4. When tightening the pipe into the valve body, hold the end of the regulator adjacent to that pipe.

Eclipse Ratio Regulator, V1, Instruction Manual 742, 5/1/2009

9

44 . 70 . . 10170. website: https://www.add-furnace.com/ : 02-888-3472
Line ID: @add11 e-mail: add028883472@gmail.com
5. Connect the air pressure loading line into the vent on the top of the ratio regulator. The ratio regulators can be adjusted to bias the gas outlet pressure relative to the combustion air pressure when setting low fire flows. Adjust the regulator as described below.
Gas Bias Adjustment
NOTE: Gas-rich adjustment is limited. If the spring adjustment will not produce the desired outlet pressure, make sure that the supply pressure is at least equal to the desired outlet pressure plus the pressure drop across the regulator at the required flow.

1. Set the burner air flow to low fire according to the instructions furnished with the burner.

2. Open the gas shut-off valves to allow gas flow to the burner. Ignite the burner.

3. Measure the fuel/air ratio using a flue gas analyzer, metering orifices or estimate the ratio from flame appearance. Use a screw driver to turn the adjusting screw clockwise to increase the outlet pressure or counterclockwise to decrease to outlet pressure.

Figure 5.1. Adjustment of Outlet Pressure

4. Turn the combustion air to high fire and make sure the burners stay lit.

NOTE: Some models are equipped with a pressure tap on the upstream side. It is open when the screw inside the tap is unscrewed approximately 1/2 a turn.

10

Eclipse Ratio Regulator, V1, Instruction Manual 742, 5/1/2009

44 . 70 . . 10170. website: https://www.add-furnace.com/ : 02-888-3472 Line ID: @add11 e-mail: add028883472@gmail.com
NOTES

Eclipse Ratio Regulator, V1, Instruction Manual 742, 5/1/2009

11

44 . 70 . . 10170. website: https://www.add-furnace.com/ : 02-888-3472
Line ID: @add11 e-mail: add028883472@gmail.com

:
: (bangkok) website: e-mail: .(): : Online Support: :
line ID:

Add Furnace Co.,Ltd. 44 . 70 . . 10170. https://www.add-furnace.com/ sales @add-furnace.com add028883472@gmail.com 08-08-170-170, 088-300-1122 02-888-3472 Line ID: @add11 Wechat ID: add0883001122 02-888-3258 @add11

Instruction Manual 742, 5/1/2009

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals