BYD LVS 4.0 48V Li Ion Solar Battery Storage User Guide

June 6, 2024
BYD

BYD logo BYD Battery-Box Premium
Quick Start Guide
LVS 4.0,8.0,12.0,16.0,20.0,24.0
V1.0BYD LVS 4.0 48V Li Ion Solar Battery Storage BYD Europe B.V.

BYD LVS 4.0 48V Li Ion Solar Battery Storage - icon

https://play.google.com/store/apps/details?id=com.byd.rjkfb.bbox

|

https://apps.apple.com/de/app/be-connect-app/id1499556855

---|---

Legal Provisions

All the information in this document is the property of BYD Europe B.V. No part of this document could be reproduced in any way for business use. Internal use is allowed.
BYD Europe B.V. makes no representations or warranties express or implied, with respect to this document or any of the equipment and/or software it may describe, including (with no limitation) any implied warranties of utility, merchantability, or fitness for any particular purpose. All such representations or warranties are expressly disclaimed. Neither BYD Europe B.V. nor its distributors or dealers shall be liable for any indirect, incidental, or consequential damages under any circumstances.
The exclusion of implied warranties may not apply in all cases under some statutes, and thus the above exclusion may not apply.
Specifications are subject to change without notice. Every effort has been made to make this document complete, accurate, and up-to-date. However, BYD Europe B.V. may need to make some improvements under certain circumstances without advance notice. BYD Europe B.V. shall not be responsible for any loss caused by this document, including, but not limited to omissions, errors, typographical errors, arithmetical errors, or listing errors in this document.
All trademarks are recognized.

Limited Warranty

You can download the current Limited Warranty from the Internet at websites:
BYD Global Service, www.bydbatterybox.com,
BYD service partner in Europe, www.eft-systems.de,
BYD service partner in Australia, www.alpspower.com.au.
BYD Europe B.V.
‘s-Gravelandseweg 256, 3125 BK, Schiedam, the Netherlands

Information on this Document

1.1. Validity
This document is valid for the Battery-Box Premium LVS 4.0, 8.0, 12.0, 16.0, 20.0, 24.0.
1.2. Target Group
The instructions in this document may only be performed by qualified persons who must have the following skills:

  • Knowledge of how batteries work and are operated
  • Knowledge of how an inverter works and is operated
  • Knowledge of, and adherence to the locally applicable connection requirements, standards, and directives*
  • The local standard for Australia is AS/NZS 5139:2019
    • Knowledge of, and adherence to this document and the associated system documentation, including all safety instructions
    • Training in dealing with the hazards associated with the installation and operation of electrical equipment and batteries
    • Training in the installation and commissioning of electrical equipment

Failure to do so will make any manufacturer’s warranty, guarantee or liability null, and void unless you can prove that the damage was not due to non- compliance.
1.3. Content and Structure of this Document
This document contains safety information and instructions on installing, connecting, and commissioning. Please finish reading this document before taking any actions on the battery system.
The latest version of this document and the manual for installation, commissioning, and operation are to be found in PDF format at our websites.
This document only contains brief information and may deviate from the real system.

Safety

2.1. Intended Use
The battery system is for residential and works with a photovoltaic system. It is a 48V Li-ion battery storage system, with the control module on itself. It could be operated in on-grid mode with
compatible inverters.
The system should be operated together with Battery-Box Premium LV BMU. The overall system could be connected with the Internet through a network cable for diagnosis and firmware updates.
The system must only be used as stationary equipment.
The system is suitable for indoor and outdoor use.
The system must only be operated in connection with a compatible inverter. The list (BYD Battery-Box Premium LVS Minimum Configuration List) of these inverters could be read on our
websites.
The system is not suitable for supplying life-sustaining medical devices. Please ensure that no personal injury would lead due to the power outage of the system.
Alterations to the BYD system, e.g., changes or modifications are not allowed unless the written permission of BYD is achieved.
Please download Be Connect from Google Play or App Store to accomplish the commissioning of the system.
The enclosed document is an integral part of this system. Keep the documentation in a convenient, dry place for future reference and observe all instructions contained therein.
The type label should always be attached to the system.
2.2. IMPORTANT SAFETY INSTRUCTIONS
The system has been designed and tested under international safety requirements. However, to prevent personal injury and property damage and ensure the long-term operation of the system, please do read this section carefully and observe all safety information at all times.
2.2.1. Battery Module Leakage
If the battery modules leak electrolytes, contact with the leaking liquid or gas should be avoided. The electrolyte is corrosive, and the contact may cause skin irritation and chemical burns. If one is
exposed to the leaked substance, do these actions:
Inhalation: Evacuate the contaminated area and seek medical help immediately.
Eye contact: Rinse eyes with flowing water for 15 minutes and seek medical help immediately.
Skin contact: Wash the affected area thoroughly with soap and water and seek medical help immediately.
Ingestion: Induce vomiting and seek medical help immediately.
2.2.2. Firefighting Measures
The battery modules may catch fire when it is put into the fire. In case of a fire, please make sure that an ABC or carbon dioxide extinguisher is nearby. Water cannot be used to extinguish the fire.
Full protective clothing and self-contained breathing apparatus are required for the firefighters to extinguish the fire.
2.2.3. Battery Modules Handling and Storage Guide

  • The battery modules and their components should be protected from damage when transporting and handling.
  • The weight of the system may cause injury risk. Please take the weight of the system into account while the system is transported and lifted carefully.
  • Do not impact, pull, drag, or step on the battery modules.
  • Do not insert unrelated objects into any part of the battery modules.
  • Do not throw the battery module into a fire.
  • Do not soak the battery modules in water or seawater.
  • Do not expose to strong oxidizers.
  • Do not short circuit the battery modules.
  • The battery modules cannot be stored at high temperatures (more than 60 ℃).
  • The battery modules cannot be stored directly under the sun.
  • The battery modules cannot be stored in a high humidity environment.
  • Use the battery modules only as directed.
  • Do not use the battery modules if it is defective, or appears cracked, broken, or otherwise damaged, or fail to operate.
  • Do not attempt to open, disassemble, repair, tamper with, or modify the battery modules. The battery modules are not user-serviceable.
  • Do not use cleaning solvents to clean the battery modules.

2.2.4. Notice of Property Damage
If the battery system doesn’t start at all, please contact BYD’s authorized service partner within 48 hours. Otherwise, the battery could be permanently damaged.
When the system is installed, it needs to be able to charge and discharge to avoid a deep discharge condition. After the installation, this needs to be checked once a month. If the battery system is not
working normally, please get in contact with your local service partner.
During the storage of the battery system, please mind the maximum storage time.
2.2.5. Surge Protection
Overvoltages (e. g. in the event of a flash of lightning) can be further conducted into the building and to other connected devices in the same network via the network cables or other data cables if there
is no surge protection.
Ensure that the system is integrated into the existing surge protection.
2.2.6. Safety Information of the Inverter Manufacturer
Please read and observe all safety information of the inverter manufacturer.

Symbols on the Battery System

Symbol Explanation
Observe the documents

Observe all documents supplied with the system.
| Grounding conductor
This symbol indicates the position for connecting a grounding conductor.
| WEEE designation
Do not dispose of the system together with the household waste but in accordance with the disposal regulations for electronic waste applicable at the installation site.
| CE marking
The system complies with the requirements of the applicable EU directives.
| Place it straight up, without inclination or upside down.
| Handle with care
| Keep it dry
| Keep the battery modules away from open flame or ignition sources.
| Beware of electrical voltage.
| Beware of a danger zone.
This symbol indicates that the system must be additionally grounded if additional grounding or equipotential bonding is required at the installation site.
| Keep the battery modules away from children.
| RCM (Regulatory Compliance Mark), a brief guide to electrical
equipment approvals in Australia
| Do not short circuit.

EU Declaration of Conformity

The battery system described in this document complies with the applicable European directives.
The certificate is available in the download area of our websites.

Technical Parameters

| | | | | |
---|---|---|---|---|---|---
Battery Module|

LVS (4 kWh,51.2 V. 45 kg)

Number of Modules| 1| 2| 3| 4| 5|

6

Usable Energy [1]| 4 kWh| 8 kWh| 12 kWh| 16 kWh| 20 kWh| 24 kWh
Max Cont. Output Current [2]| 65 A| 130 A| 195 A| 250 A| 250 A| 250 A
Peak Output Current [2]| 90 A, 5 s| 180A, 5 s| 270A, 5 s| 360A, 5 s| 360A, 5s| 360 A, 5 s
Dimensions (H/W/D)| 478 x
650 x 298 mm| 711 x
650 x 298 mm| 944 x
650 x 298 mm| 1177 x
650 x 298 mm| 1410 x
650 x 298 mm| 1643 x
650 x 298 mm
Weight| 64 kg| 109 kg| 154 kg| 199 kg| 244 kg| 289 kg
Nominal Voltage| 51.2 V
Operating Voltage| 40-57.6 V
Operating Temperature| -10 °C to +50°C
Battery Cell Technology| Lithium Iron Phosphate (cobalt-free)
Communication| CAN / RS485
Enclosure Protection Rating| IP55
Round-Trip Efficiency| 295%
Scalability [3]| Max. 64 Modules in Parallel (256 kWh)| Single Tower Only
Certification| VDE2510-50 / IEC62619 / CE / CEC / UN38.3
Applications| ON Grid / ON Grid + Backup / OFF Grid
Warranty [4]| 10 Years
Compatible Inverters| Refer to BYD Battery-Box Premium LVS Minimum Configuration List
Battery Designation| IFpP/47/174/120/16S/M/-10+50/90
[1] DC Usable Energy, Test conditions: 100% DOD, 0.2C charge & discharge at + 25 °C. System Usable Energy may vary with different inverter brands
[2] Charge derating will occur between -10 °C and +5 °C
[3] Parallel tower function only available for 1 to 4 battery modules per tower. LVS 20.0 and LVS 24.0 can only be used as a single tower.
[4] Conditions apply. Refer to BYD Battery-Box Premium Limited Warranty Letter.

Instructions

1. Scope of Delivery

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions1  BYD LVS 4.0
48V Li Ion Solar Battery Storage - Instructions2

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions3

2. Not included in Scope of Delivery

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions4

3. Tools
BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions5

4. Installation Location

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions6

5. Module Parallel Connection Limitation

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions7

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions9

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions10

6. Installation

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions11

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions12

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions13

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions14

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions15

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions16

7. Connection Diagram

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions17

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions18

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions19

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions20

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions23

8. Connecting the Grounding Conductor

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions24

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions25

9. Connecting the Data Cable

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions29

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions30

9.1 To Connect Data Cable.

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions32

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions33

9.2 Cover the Terminal Resistor

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions34

10. Connecting the DC Power Cable

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions36BYD LVS 4.0 48V
Li Ion Solar Battery Storage - Instructions37

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions38

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions40BYD LVS 4.0 48V
Li Ion Solar Battery Storage - Instructions41

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions42

11. Commissioning
11.1 Switch on the Battery System

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions45

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions58

11.2 Configuration

BYD LVS 4.0 48V Li Ion Solar Battery Storage - icon

https://play.google.com/store/apps/details?id=com.byd.rjkfb.bbox

|

https://apps.apple.com/de/app/be-connect-app/id1499556855

---|---

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions46

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions48+

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions49

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions50

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions51

11.3 Switch on the Inverter

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions55

12. Operation
12.1 Start Procedure

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions56

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions53

12.2 Switch off Order

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions58

13. Extension

BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions59

14. LED status

Flashing white and blue alternatively| BYD LVS 4.0 48V Li Ion Solar Battery
Storage - Instructions60| The battery system is initiated.
---|---|---
Glowing white| BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions61| Idle (the battery system is neither charging nor discharging).
Flashing white slowly| BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions62| The battery system is charging.
Flashing white quickly| BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions63| The battery system is discharging.
Flashing white and glowing blue| BYD LVS 4.0 48V Li Ion Solar Battery
Storage - Instructions64| The battery system is discharging, and the SOC of Battery-Box is below 15%.
Flashing white and blue| BYD LVS 4.0 48V Li Ion Solar Battery Storage -
Instructions65| An error has occurred.

Contact

BYD Global Service
Mailbox: [email protected]
Telephone: +86 755 89888888-47175
Address: No.3009,BYD Road,
Pingshan,Shenzhen,518118,P.R.China
Website: www.bydbatterybox.com| Social media link:
https://www.facebook.com/BatteryBoxBYD/
https://twitter.com/BYD_BatteryBox
https://www.linkedin.com/company/byd-battery-box
---|---
USA
EFT USA
Mailbox: [email protected]
Telephone: +1(833) 338-8721
Website: www.eft-systems.de/us| Australia Alps Power Pty Ltd
Mailbox: [email protected]
Telephone: +61 2 8005 6688
Address: 14/47-51 Lorraine St
Peakhurst NSW 221
Website: www.alpspower.com.au
Europe
EFT-Systems GmbH
Mailbox: [email protected]
Telephone: +49 9352 8523999
+44 (0) 2037695998(UK)
+34 91 060 22 67(ES)
+39 02 873683(IT)
Address: Bruchtannenstraße 28,
63801 Kleinostheim, Germany
Website: www.eft-systems.de| South Africa
SOLARVILLAGE(PTY)LTD
Mailbox: [email protected]
Telephone: + 27 83 3755 486
Address: UNIT 45 DENNEKAMP, SAILSBURY ROAD, KENILWORTH,
CAPE TOWN, WESTERN CAPE,7708

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BYD User Manuals

Related Manuals