Perfect Prime AQ380 Multi Iaq Monitor Instruction Manual

June 15, 2024
Perfect Prime

MULTI IAQ MONITOR
AQ380
Instruction Manual

www.perfectprime.com

APPLICATION

This air quality meter can measure and display CO2, PM2.5, Humidity and Temperature measurements and is ideal for monitoring indoor air quality in a variety of environments.

 ACCESSORIES

1 Meter (with a 3.7V Rechargeable lithium battery)
1 User’s Manual
1 Micro USB cable

SAFETY PRECAUTION

| Caution! Please refer to this manual.
Improper use may damage the meter and its components.
---|---
| Complies with European Directive.

  • Do not operate in environments with flammable gas or humid environments.
  • Operating altitude: up to 2000M.
  • Operating environment: Indoor use; Pollution degree 2.
  • Clean with soft cloth when dirty, such as glasses cloth. Do not clean with chemicals and other solvents.
  • EMC: EN61326-1:CISPR 11:Group 1, Class B
    • Class B – Equipment for use in all establishments other than domestic.
    • Group 1 – RF energy generated is needed for internal functioning.

INSTRUMENT DESCRIPTION

4.1 FEATURE AND FUNCTION

Perfect Prime AQ380 Multi Iaq Monitor - FEATURE AND
FUNCTION

  1. LCD
  2. Right-side button
  3. Memory reading / Up button
  4. MAX / MIN / AVG button
  5. Power button
  6. Single log and auto-record button/Down button
  7. Temperature and humidity sensing port
  8. Air outlet for sensor
  9. Air inlet for sensor
  10. Micro USB jack

4.2 INDICATION ON THE LCD DISPLAY

  1. MAX / MIN /AVG /MAN MIN
  2. Manual recording
  3. Auto-recording
  4. Read record
  5. Battery indicator
  6. Auto-power off
  7. Buzzer
  8. Alarm
  9. CO2
  10. PM2.5
  11. Temperature
  12. MM minute, SS second
  13. PM10
  14. Humidity

OPERATION

Please hold the meter in the following way for the correct measured value:

The placement follows the electrical specifications described in Section 7.

This is a suitable way to hold the meter, holding for a long time may affect the accuracy.

This is not a proper way to hold the meter, it will block the temperature and humidity sensors.

This is not a proper way to hold the meter, it will block the PM2.5, PM10 and CO2 sensors.

5.1 Power on/off
Press to turn the power on or off.

5.2 Auto Power Off
At the power-on status, press and hold for more than 2 seconds to disable or resume auto power off function. When auto power off is activated, the indicator appearing, and it will automatically turn off after 30 minutes.

5.3 Backlight mode
Press “right-side button” to turn on or off the backlight. (When the red backlight for alarm is on, this button is invalid) The backlight mode is turned off automatically after 15 seconds.

5.4 MAX/MIN AVG and MAN MIN
Press to enter this function, the MAX is shown on the screen and it displays the maximum value.
Press repeatedly to select the function of MIN/AVG/MAX MIN/MAX and update the displayed value. When select MAX MIN function, it displays the current measured value.

5.5 REC Manual record
Press to save one data log, the “REC” and the log number appear on the LCD for one second. For an example of the log number 10, it will increase by 1 when pressing every time. When reaching the maximum log number 20, appears.

5.6 LOG starts the auto-recording function
Press and hold for more than 2 seconds, “LOG” appears on the LCD, and auto- recording starts. If the power is insuffcient during auto-record- ing, appearing, auto-recording will be forcibly stopped. When reaching themaximum log number 20, appears.
Press and hold again for more than 2 seconds to exit the auto-recording function.

5.7 Read the data recorded in the memory
Press to enter the memory-reading mode, while and the log number appear on the LCD for one second, the record is then displayed. Read the data recorded in the memory with or .
Press and hold to exit this mode.

5.8 °C or °F units
At the shutdown status, press and hold , then press to turn on the meter, after the software version appears, release .
Repeat the above steps to switch the unit.

5.9 Clear memory
At the shutdown status, press and hold and then press to turn on the meter, the and software version appears successively on the LCD, release the to clear the memory.

5.10 Turn on / off the key sound
The sound is defaulted as on and the is displayed. At the shutdown status, press and hold and then press to turn on the meter, after the software version appears, release and the disappears, the key sound is off.
Repeat the above step to tun on the key sound.

5.11 Resume the factory settings
At the shutdown status, press and hold “right-side button” and then press, the and software version appears successively on the LCD, release the “right-side button” to complete the process of resuming to the factory settings and clearing the memory.

  • Auto-shutdown: OFF
  • Key sound: On
  • The calibration value resumed to 0
  • CO2 Abc OFF
  • Memory cleared

5.12 Function settings
Press “right-side button” for more than 2 seconds to enter the setting mode.
Press the “right-side button” repeatedly to enter the setting function 1 ~ 8 in sequence:

SET 1. Time interval setting

  1. The LCD displays:
  2. Press or to select the interval 5 seconds / 10 seconds / 5 minutes / 10 minutes / 20 minutes / 30 minutes / 60 minutes; the default value is 5 seconds.
  3. Press the “right-side button” again to enter set 2.

SET 2. CO2 alarm setting

  1. The LCD displays:
  2. Press to move the digit, and the selected digit will flash.
  3. Press or to increase or decrease the CO2 value.
  4. Press the “right-side button” again to enter set 3.

SET 3. PM2.5 alarm setting

  1. The LCD displays:
  2. Press to move the digit, and the selected digit will ash.
  3. Press or to increase or decrease the value.
  4. Press the “right-side button” again to enter set 4.

SET 4. PM10 alarm setting

  1. The LCD displays:
  2. Press to move the digit, and the selected digit will flash.
  3. Press or to increase or decrease the value.
  4. Press the “right-side button” again to enter set 5.

SET 5. (Factory use only) CO2 Abc self-calibration mode

  1. The LCD displays:
  2. This is for factory calibration use only. Please do not change it.
  3. Click the “right-side button” again to enter set 6.

SET 6. CO2 manual calibration

  1. The LCD displays:
  2. Directly increase or decrease the displayed value of CO2, press the to move the digit, and the selected digit will flash.
  3. Press or to modify the value.
  4. Press the “right-side button” again to enter set 7.

SET 7. Temperature calibration

  1. The LCD displays:
  2. Directly increase or decrease the displayed value of CO2, press the to move the digit, and the selected digit will flash.
  3. Press or to modify the value.
  4. Press the “right-side button” again to enter set 8.

SET 8. Humidity calibration

  1. The LCD displays:
  2. Directly increase or decrease the displayed value of CO2, press the to move the digit, and the selected digit will flash.
  3. Press or to modify the value.
  4. Press the right-side button again to return to the measurement mode.

GENERAL SPECIFICATIONS

  • Real-time measurement of CO2/PM2.5/PM10/temperature/humidity.
  • Maximum / minimum / average value.
  • Auto-power on / off function.
  • Adjustment and calibration function (CO2/temperature/humidity).
  • CO2/PM2.5/PM10 red backlight alarm.
  • Manual record and auto-record.
  • Key sound assists to ensure the operation works.
  • Overload indication .
  • Battery: 3.7V 2000mAh rechargeable lithium battery
  • Transformer for charging: 1A/5V
  • Battery life: continuous use for approximately 6 hours
  • 5V micro USB interface for external power supply
  • When battery-low indicator shows as the following figure, the power will be turned off after 5 seconds.
  • Charging indication: The battery indicator will sequentially vary as from right to left during charging and keep when fully charged.
  • °C or °F unit selection.
  • When the external power supply is connected, the auto-power off is disabled, and the white backlight is always on.
  • CO2 /PM2.5/PM10 red backlight alarm setting function
    Setting value| CO2| PM2.5| PM10
    ---|---|---|---
    1000PPM| 35µg/m³| 75µg/m³

When the measured value reaches the setting value for alarm, the LCD backlight shines in red and related measurement items flash.

  • 20 logs for manual and automatic recording values.
  • Auto-recording time interval setting: 5 seconds, 10 seconds, 5 minutes, 10 minutes, 20 minutes, 30 minutes, 60 minutes.
  • Sampling time: 2.5 seconds (5 types, 0.5 seconds for each).
  • Dimensions: 150x65x22mm (L x W x H).
  • Weight: 190 g.
  • Operating temperature and humidity: 0°C ~ +50°C, <80%RH (no condensation).
  • Storage temperature and humidity: 0°C ~ +60°C, <70%RH (no condensation).
  • Display size: 52mm (L) x 40mm (W).

CAUTION
If to use the meter in a high-humidity environment, please place the meter in a low-humidity environment for 24 hours after use.

Ambient temperature range for accurate measure: 18°C (64°F) ~ 28°C (82°F)
6.1 PM2.5

SENSOR LASER PARTICULATE MATTER SENSOR
Measuring range 0-500 μ g/m3
Accuracy ±8 g :<=50µg/m3

±10% of reading value:>50µg/m3
Resolution| 1
Reaction time| <10seconds

6.2 PM10

SENSOR LASER PARTICULATE MATTER SENSOR
Measuring range 0-500 µg/m3
Accuracy ±10 g :<=50µg/m3

±15% of reading value:>50µg/m3
Resolution| 1
Reaction time| <10seconds

6.3 CO2

SENSOR NON-DISPERSION INFRARED (NDIR)
Measuring range 400 to 9999ppm
Accuracy ±70ppm ±3% of readings.

(400-2000ppm)
Resolution| ±1ppm
Reaction time| 90% during about 2 minutes

6.4 TEMPERATURE

SENSOR BANDGAP TEMPERATURE SENSOR
Measuring range -10°C~50°C / 14°F~122°F
Accuracy ±1.0°C/±1.8°F

(Non-charging and 30 minutes after charging)
Resolution| 0.1°C / 0.1F (0~35°C / 32°F~95°F) ; 1°C / 1°F
(Above 100°C /°F or below -10°C /°F)
Reaction time| About 1 second

6.5 HUMIDITY

SENSOR CAPACITIVE HUMIDITY SENSOR
Measuring range 1-99%
Accuracy ±5.0%RH(10~90%);

±8.0%RH(<10%,>90%) no condensation, at 25°C
Resolution| 0.10%
Reaction time| About 4 seconds

NEW AIR QUALITY STANDARD

Schematic diagram of concentration grade| Air quality level| Average standard value of PM2.5 in 24 hours.
---|---|---
| Excellent| 0-35
| Good| 35-75
| Slight pollution| 75-115
| Moderate pollution| 115-150
| Heavy pollution| 150-250
| Serious pollution| >250

MAINTENANCE OR REPAIR

  1. For the battery-low indicator: indicates the battery full; indicates the battery low, please charge it in time.

  2. If dirty, please wipe it with a soft cloth, such as a glasses cloth.
    Do not wipe it with chemical solvents.

  3. If fault on the meter, it can only be sent to the authorized service suppliers or sent back to the original factory for maintenance.

CAUTION
When the LCD shows the battery-low indicator , please charge it in time.

PRODUCT DISPOSAL

Caution: This symbol indicates that this product and its accessories shall be subject to a separate collection and correct disposal, please not throw it away directly to avoid environmental pollution.

CUSTOMER SERVICE INQUIRIES
Your emails are important to us so we strive to reply all inquiries and emails within 24 hours. In exceptional cases, we may require more time to respond.
Thank you for your understanding.
For more information about our products and services, please send us an email: cs@perfectprime.com
For B2B or project-based application, please send an email: sales@perfectprime.com
FOR MORE INFORMATION ABOUT PERFECTPRIME PLEASE VISIT OUR ABOUT US PAGE AND FEEL FREE TO BROWSE.

Scan QR Code for the Youtube channel for video manual| Scan QR Code for the Product Manual page (Multi-Language available for certain products)| Scan QR Code to register the product for 1 year warranty
---|---|---
| | Perfect Prime AQ380 Multi Iaq Monitor - Qr code 3
http://qr.w69b.com/g/r4oLxa2l2| http://qr.w69b.com/g/qRw248shO| http://qr.w69b.com/g/mT0iM63Vm

Retailer Tyche Smart Limited
Email cs@perfectprime.com
Address 2nd Floor, 107 Charterhouse Street,
EC1M 6HW, London, England UNITED KINGDOM
Telephone +44 203 7695377

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Perfect Prime User Manuals

Related Manuals