General information.

  • The unit consists of a plastic body with a diffusor and an on/off switch. The power supply is designed via the mains with a nominal 220v, 50 Hz.
  • This unit is designed for domestic, office or manufacturing premises.
  • Dimension shown as on Picture 1

OPTONICA T5 LED Tubes

Technical Specifications.

  • Power supply 220-240V~50/60 Hz;
  • LED type: SMD 2835 LED;
  • Electric power protection class – – II;
  • Ingress protection rate – IP20.

SKU:| Power,W| Light Color| Fluxi m| MaxUnits in
line up to 30m| LEDs Number| Beam
Angle| Ra| Size mm
---|---|---|---|---|---|---|---|---
5550,5551,5552| 4W| 6000K/4920K/2700K| 3201m| 100| 22| 120°| >80| 305x22x32
5553,5554,5555| 8W| 6000K/4500K/2700K| 6401m| 50| 40| 570x22x32
5556,5557,5558| 12W| 6000K/4500K/2700K| 9601m| 33| 60| 870x22x32
5559,5560,5561| 16W| 6000K/4500K/2700K| 12801m| 25| 80| 1170x22x32
5562,5563,5564| 20W| 6000101500K/2700K| 16001m| 20| 100| 1470x22x32
5565,5566,5567| 4W| 6000K/4500K/2700K| 3201m| 100| 22| 305x22x32
5568,5569,5570| 8W| 6000K/4500K/2700K| 6401m| 50| 40| 570x22x32
5571,5572,5573| 12W| 6000K/4500K/2700K| 9601m| 33| 60| 870x22x32
5574,5575,5576| 16W| 6000K/4500K/2700K| 12801m| 25| 80| 1170x22x32
5577,5578,5579| 20W| 6000K/4500K/2700K| 16001m| 20| 100| 1470x22x32

What is in the box.

OPTONICA T5 LED Tubes - box

  1. The main LED unit – 1 piece.
  2. Power supply cable 1м – 1 piece.
  3. Connecting cable – (optional)*
  4. Rigid connector 1 piece.
  5. Metal clips 2 pieces.
  6. Screws 2 pieces.
  7. Operation Manual 1 piece.
  8. Package box- 1 piece.

Installation and connecting the unit.

  • Open the box and check its contents.
  • Install the unit in the designated place using the metal clips as shown in pictures .3-1.
  • Connect the power cable to the unit (Picture.3-2).
  • Connect the power cable to the mains 220 V.
  • Turn on the unit using the on/off switch which is on the body.
  • If necessary you may connect a few units in line using the rigid connectors (picture 3-3) or the flexible connecting cable (Рicture. 3-4).
  • ATTENTION! The maximum number of units connected in-line together is shown in the table above.

OPTONICA T5 LED Tubes - fig1

Safety Precautions.

  • Installing the unit can only be undertaken by a qualified electrician. Serious injury/death or property damage may occur if otherwise.
  • Installing or servicing the unit can only be undertaken when the power is completely cut off.
  • Do not attempt to operate or service the unit if the body, plugin or cable are damaged..
  • Ensure that the unit is not dropped or damaged by a physical force.
  • In case the unit does not operate properly – stop using it immediately, disconnect it from the power supply and seek professional assistance.
  • Never install or maintain the unit if you are not a qualified electrician. Serious injury/death or property damage may occur if otherwise

Recycling.

  • The unit does not contain any valuable or toxic substances that require special recycling. Recycling is made via regular methods.

Transporting and storing.

  • Any means of transport is allowed provided that the package is not exposed to the elements or damage risk.
  • Store only unpacked indoors with natural ventilation with air temperature below 20 C up to +40°С and relative humidity not higher than 90 % (if no condense is formed).

Warranty.

  • Warranty against manufacturing defect is 12 months from the purchase date.
  • If any anomaly occurs – please contact your authorized dealer. You may be required to provide a valid proof of purchase and deliver the unit to a customer service point.

ATTENTION! Warranty does not cover:

  • Damages made by mechanical force or use outside the normal design purposes;

  • Any case in which damage has been caused by not following the operating manual.

  • Any case in which the unit has been opened or tampered with by an unauthorized service agent.

  • Sold separately – various lengths
    IMPORTER: Prima Group 2004 LTD,
    Bulgaria, 1784 Sofia, Mladost 1, bl. 144,
    Ground Floor; Phone: +359 2 988 45 72;

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals