LED Panel Kit Conflating Of * LED panel and suitable wattage constant current LED Driver

Safety warnings

2.1. Before installation & use  read the instructions fully; keep for future reference
2.2. This product must be Installed by a licensed electrician
2.3. If the packaging & contents appear to be damaged, do not continue installation & return it to point of purchase.
2.4. It Is recommended that this product be used on a circuit protected by an Earth Leakage Circuit Breaker or Safety Switch.
2.5. Before attempting to maintain or repair or replace a light fitting. always ensure the circuit is not energised (the mains switch is turned OFF) and ensure luminaire/components are fully cooled.
2.8. The fitting must be so Installed that It is separated from the surfaces and objects It Illuminates, by at least 0.1m to prevent undue temperature rise that may cause ignition and/or deterioration.
2.7. Install well clear of any heat sensitive, flammable and explosive materials or objects, curtains or drapes
2.8. Allow suitable ventilation d alr flow around the light fitting.
2.9. DO NOT COVER – Under no circumstances, the fitting, driver, lamp end for any parts of them. shall be covered with any type of insulation material or any other material
2.10. Do not Immerse the light fitting. or any part of it In water or any other liquids.
2.11. Always ensure light fitting is fully assembled and all covers are in place before connecting to the power supply.
2.12. Regularly Inspect the light fittings for any damage. If found defective In any way Immediately cease use.
2.13. Do not attempt to modify this light fitting in any way from the condition as supplied.
2.14. Before making fixing hole(s)or cut-out, check that there are no obstructions hidden beneath the mounting surface such as pipes or cables.
2.16. Use Only approved extension leads & always fully uncoil cord, ensure socket connections are protected from water & wet weather.
2.16. Ensure bare hands do not contact any part of the light fitting & its ancillary control gear.while in operation (turned ON).
2.17. The LED driver Is a class II Item & need not be earthed. When mounting multiple fixtures to conductive structures. it is recommended that the structure is earthed. 2.18.Always dispose of packaging in an environmentally friendly manner.

Preceutions & limitations

3.1. Location: Indoors! Interior locations only.
3.2. Normal Operating Position: Horizontal on rigid horizontal ceiling surface
3.3. Positioning of Light Fitting:
3.3.1. Ensure that a minimum clearance all around Is provided between the luminaire and structural members, thermal insulation and any other substance
3.3.2. Suitable for direct mounting on normally flammable surface
3.3.3. Mounting Methods: ‘Recessed ‘Surface mounted (with appropriate accessory) ‘Suspension (with appropriate accessories)
3.3.4. Ensure that any part of the light fitting or the driver is not covered with any combustible materials or insulation; minimum spacings nominated for these materials are mandatory.
3.3.5. Abutment to the Light Fitting trim with any thermal Insulation material must be within the maximum permissible distance in accordance with the regulation; No element of the Light Fitting’s thermal management fins heat sink is covered.
3.4. Positioning the Driver:
3.4.1. The driver must be placed in a well-ventilated location and free from direct contact with any insulating material
3.4.2. Minimum clearance between thermal insulation and the Driver must be ensured
3.4.3. Routing of wiring: The supply (primary) wiring and secondary wiring from Um driver should not be permitted to cross or be routed on the same path.
3.4.4. Secondary lead/ lamp wire extension: Output leads must not be extended.
3.5. Installation Cut-out: The installation cut out sizes prescribed in this document is nominal dimension only. The actual dimensions of the individual downllght may slightly vary. Hence, the actual Installation cut-out must be accurately measured with respect to the product by the installer end tried out on a trial template before cutting out the mounting surface or ceiling.
3.6. Fault finding &Circuit Testing: The Integrity of the circuit MUST NOT be checked with a Wegner’ because the injection of 1000-1500V may irreparably damage the components in the LED driver.
3.7. Always, disconnect the LED Driver from the electrical supply before flash or high voltage testing. (if and when testing is done)

Care & cleaning

4.1. Turn off the fitting first.
4.2, For cleaning, wipe over with a damp cloth & allow to dry off before using the unit
4.3. Do not use strong chemicals, acidic or hydrocarbon-based solvents or abrasive cleaning compounds on any part of the fitting
§.Installation procedure
5.1. Ensure the power to the circuit being used is isolated and will stay isolated until the job is complete-Lock out & Tag out.
5.2. Remove the light fittings and all components from the carton & ensure all packaging materials are fully removed before usage. Ensure that the components, driver & controllers, accessories that may have been separately packed and shipped are all available and suitable ones for the light fitting and installation on hand.
5.3. Contents of the carton are:
5.3.1. LED Panel/s
5.3.2. Driver (one each per panel)
5.3.3. This installation & user manual
5.4. Take care not to damage the conductors.
5.5. Installation of the light fitting
5.5.1. Depending on the selected installation method and mounting surface
5.5.2. Complete installation while power to circuit if isolated (OFF); Lock Out & Tag out
5.6. Remove the Lock-Out Tag; Energise the circuit at the switchboard; turn the switch to ON’.

Installation methods with schematic diagrams

6.1 Cut size of holes:580°580mmOPTONICA DL40 A1 LED Panel 60x60 120lm W -
fig6.2. Recessing: This light fitting / driver is not dimmable
6.2.1. Recessed installation in standard T-Bar grid ceilings is the most popular installation method
6.2..2. Remove the existing ceiling panel suitably to match the size of the LED panel being installed
6.2..3. Install and connect the LED driver in recessed space
6.2..4. Replace and secure LED panel in the position of removed ceiling pane! OPTONICA DL40 A1 LED Panel 60x60 120lm W - fig 16.3. Surface mounted installation [requires surface mounted frame kit (not supplied)] 6.3.1. Install and secure the driver first and connect it to the socket outlet
6.3.2. Connect the LED driver to the LED panel securely
6.3.3. Assemble and secure the mounting frame on to the rigid ceiling surface OPTONICA DL40 A1 LED Panel 60x60 120lm W - fig 26.4. Suspended installation [requires suspension cables and fasteners kit (not supplied)] 6.4.1. Securely connect all the suspension cables (twisted steel wires) to the back of the panel
6.4.2. Install and secure the driver first and connect it to the socket outlet
6.4.3. Secure each of the cables to rigid ceiling using appropriate fasteners while supporting the LED panel to avoid any strain on suspension cables
6.4.4. Adjust the length so panel can stay suspended parallel to the ceiling at required safe height.
6.4.5. Gently release the panel to prevent damage and make sure it is retained safely in place.OPTONICA DL40 A1 LED Panel 60x60 120lm W - fig
3

IMPORTER: Prima Group 2004 LTD, Bulgaria, 1784 Sofia, Mladost 1, bl. 144, Ground Floor;