OPTONICA DL40-A1 LED Panel 60×60 120lm/W User Manual
- June 2, 2024
- OPTONICA
Table of Contents
INSTALLATION AND USER MANUAL
Product Information
LED Panel Kit Conflating Of * LED panel and suitable wattage constant current LED Driver
Safety warnings
2.1. Before installation & use read the instructions fully; keep for future
reference
2.2. This product must be Installed by a licensed electrician
2.3. If the packaging & contents appear to be damaged, do not continue
installation & return it to point of purchase.
2.4. It Is recommended that this product be used on a circuit protected by an
Earth Leakage Circuit Breaker or Safety Switch.
2.5. Before attempting to maintain or repair or replace a light fitting.
always ensure the circuit is not energised (the mains switch is turned OFF)
and ensure luminaire/components are fully cooled.
2.8. The fitting must be so Installed that It is separated from the surfaces
and objects It Illuminates, by at least 0.1m to prevent undue temperature rise
that may cause ignition and/or deterioration.
2.7. Install well clear of any heat sensitive, flammable and explosive
materials or objects, curtains or drapes
2.8. Allow suitable ventilation d alr flow around the light fitting.
2.9. DO NOT COVER – Under no circumstances, the fitting, driver, lamp end for
any parts of them. shall be covered with any type of insulation material or
any other material
2.10. Do not Immerse the light fitting. or any part of it In water or any
other liquids.
2.11. Always ensure light fitting is fully assembled and all covers are in
place before connecting to the power supply.
2.12. Regularly Inspect the light fittings for any damage. If found defective
In any way Immediately cease use.
2.13. Do not attempt to modify this light fitting in any way from the
condition as supplied.
2.14. Before making fixing hole(s)or cut-out, check that there are no
obstructions hidden beneath the mounting surface such as pipes or cables.
2.16. Use Only approved extension leads & always fully uncoil cord, ensure
socket connections are protected from water & wet weather.
2.16. Ensure bare hands do not contact any part of the light fitting & its
ancillary control gear.while in operation (turned ON).
2.17. The LED driver Is a class II Item & need not be earthed. When mounting
multiple fixtures to conductive structures. it is recommended that the
structure is earthed. 2.18.Always dispose of packaging in an environmentally
friendly manner.
Preceutions & limitations
3.1. Location: Indoors! Interior locations only.
3.2. Normal Operating Position: Horizontal on rigid horizontal ceiling surface
3.3. Positioning of Light Fitting:
3.3.1. Ensure that a minimum clearance all around Is provided between the
luminaire and structural members, thermal insulation and any other substance
3.3.2. Suitable for direct mounting on normally flammable surface
3.3.3. Mounting Methods: ‘Recessed ‘Surface mounted (with appropriate
accessory) ‘Suspension (with appropriate accessories)
3.3.4. Ensure that any part of the light fitting or the driver is not covered
with any combustible materials or insulation; minimum spacings nominated for
these materials are mandatory.
3.3.5. Abutment to the Light Fitting trim with any thermal Insulation material
must be within the maximum permissible distance in accordance with the
regulation; No element of the Light Fitting’s thermal management fins heat
sink is covered.
3.4. Positioning the Driver:
3.4.1. The driver must be placed in a well-ventilated location and free from
direct contact with any insulating material
3.4.2. Minimum clearance between thermal insulation and the Driver must be
ensured
3.4.3. Routing of wiring: The supply (primary) wiring and secondary wiring
from Um driver should not be permitted to cross or be routed on the same path.
3.4.4. Secondary lead/ lamp wire extension: Output leads must not be extended.
3.5. Installation Cut-out: The installation cut out sizes prescribed in this
document is nominal dimension only. The actual dimensions of the individual
downllght may slightly vary. Hence, the actual Installation cut-out must be
accurately measured with respect to the product by the installer end tried out
on a trial template before cutting out the mounting surface or ceiling.
3.6. Fault finding &Circuit Testing: The Integrity of the circuit MUST NOT be
checked with a Wegner’ because the injection of 1000-1500V may irreparably
damage the components in the LED driver.
3.7. Always, disconnect the LED Driver from the electrical supply before flash
or high voltage testing. (if and when testing is done)
Care & cleaning
4.1. Turn off the fitting first.
4.2, For cleaning, wipe over with a damp cloth & allow to dry off before using
the unit
4.3. Do not use strong chemicals, acidic or hydrocarbon-based solvents or
abrasive cleaning compounds on any part of the fitting
§.Installation procedure
5.1. Ensure the power to the circuit being used is isolated and will stay
isolated until the job is complete-Lock out & Tag out.
5.2. Remove the light fittings and all components from the carton & ensure all
packaging materials are fully removed before usage. Ensure that the
components, driver & controllers, accessories that may have been separately
packed and shipped are all available and suitable ones for the light fitting
and installation on hand.
5.3. Contents of the carton are:
5.3.1. LED Panel/s
5.3.2. Driver (one each per panel)
5.3.3. This installation & user manual
5.4. Take care not to damage the conductors.
5.5. Installation of the light fitting
5.5.1. Depending on the selected installation method and mounting surface
5.5.2. Complete installation while power to circuit if isolated (OFF); Lock
Out & Tag out
5.6. Remove the Lock-Out Tag; Energise the circuit at the switchboard; turn
the switch to ON’.
Installation methods with schematic diagrams
6.1 Cut size of holes:580°580mm6.2. Recessing: This light fitting / driver is not
dimmable
6.2.1. Recessed installation in standard T-Bar grid ceilings is the most
popular installation method
6.2..2. Remove the existing ceiling panel suitably to match the size of the
LED panel being installed
6.2..3. Install and connect the LED driver in recessed space
6.2..4. Replace and secure LED panel in the position of removed ceiling pane!
6.3. Surface mounted installation [requires surface
mounted frame kit (not supplied)] 6.3.1. Install and secure the driver first
and connect it to the socket outlet
6.3.2. Connect the LED driver to the LED panel securely
6.3.3. Assemble and secure the mounting frame on to the rigid ceiling surface
6.4. Suspended installation [requires suspension
cables and fasteners kit (not supplied)] 6.4.1. Securely connect all the
suspension cables (twisted steel wires) to the back of the panel
6.4.2. Install and secure the driver first and connect it to the socket outlet
6.4.3. Secure each of the cables to rigid ceiling using appropriate fasteners
while supporting the LED panel to avoid any strain on suspension cables
6.4.4. Adjust the length so panel can stay suspended parallel to the ceiling
at required safe height.
6.4.5. Gently release the panel to prevent damage and make sure it is retained
safely in place.
IMPORTER: Prima Group 2004 LTD, Bulgaria, 1784 Sofia, Mladost 1, bl. 144,
Ground Floor;
Phone: +359 2 988 45 72;
Documents / Resources
|
OPTONICA DL40-A1 LED Panel 60x60
120lm/W
[pdf] User Manual
DL40-A1, LED Panel 60x60 120lm W, LED Panel
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>