Specifications and Technical Data
- Luminaire Category: LED Floodlight AC220-240V 50HZ/60HZ
- Ambient Temperature: -20 °C<TA<40°C
- Protection Grade: IP65
- Detection Range: 120°
- Ambient Light: 3-2000LUX (adjustable)
- Time-Delay: min: 10sec#3sec max: 8min#3min (adjustable)
- Installation Height: 1.8m~2.5m
- Detection Distance: max: 10m (TA25°C) (adjustable)
WARNING:
- ENSURE ELECTRICITY IS SWITCHED OFF BEFORE YOU INITIATE ANY MANIPULATIONS.
- Please read carefully the following instructions before commencing installation.
- Some of the necessary accessories and spare parts may not be provided including the junction box.
- The Floodlight must be earthed.
- If the safety shield is damaged, you must replace it immediately, with tempered glass.
- This is a professional-use product, any installation and/or service must be undertaken by a qualified person. Serious injury or death may occur if otherwise.
MOUNTING
- Do not install this product on an unstable surface or any such vibrating one.
- Remove the screw intended for mounting the bracket of the fixture. Remove the bracket. (see fig.2)
- Mark the hole position for fixing the bracket onto the wall. Drill the wall at the marked positions (screw not supplied). (see fig. 3)
- Screw the fixing bracket to the wall with a suitable screw (see fig.4)
- Mount the bracket back to the fixture. Adjust the floodlight to desired position and tighten the screw of the fixing bracket. Connect the mains cable (HORN-F3G1.0 mm’ recommended) with the input lead of our product through the waterproof junction box. Note the Line (-) of the lead. (see fig.5) (Junction box must be IP65 rated or above, ensure to tighten the waterproof screw)
- Turn on the power to make sure the product operates normally. Adjust the irradiation angle according to the intended condition of usage. (see fig.6)
- How to set up the adjustment. (see fig.5 .6)
- This product has an override function which is operated by a control switch. Enter override mode: switch (on and off and on) once in 1 second, it will enter the override mode to keep the state of being on. Exit override mode: When light is on, switch off and after 10 seconds switch on again, it will enter normal mode, night mode with a sensing distance of 10m (factory setting) and time-delay 8 min.
YOU MUST COMPLY strictly to these instructions, otherwise, serious injury or death may occur.
- DO NOT tamper with the integrity of this product, it may cause harm to the user otherwise. The power of final interpretation belongs to the manufacturer.
IMPORTER:
- Prima Group 2004 LTD,
- Bulgaria, 1784 Sofia,
- Mladost 1, bl. 144,
- Ground Floor;
- Phone: +359 2 988 45 72;
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>