MYPV AC-THOR, AC ELWA-E Smart Energy Meter Instruction Manual

October 30, 2023
MYPV

AC-THOR, AC ELWA-E Smart Energy Meter
with Kostal Piko IQ, Plenticore Plus or Smart Energy Meter (KSEM)
Instruction Manual

Default settings on AC•THOR or AC ELWA-E

Before commissioning, it is essential that you read the assembly instructions that accompany the device, as well as the operating instructions available on line.
Find the AC•THOR operation manual here.
Find the AC ELWA-E operation manual here.

Communication of AC•THOR or AC ELWA-E with Kostal

AC•THOR or AC ELWA-E are connected to Kostal in the network via a router. Within this network, the unit receives information from Kostal about how much excess PV power is available.
Do not connect the unit directly to the inverter or battery system!
When controlled by an inverter, a feed-in meter is required in the system. Otherwise, the query of the inverter does not provide any data.

Settings on Kostal

With the “Kostal PIKO IQ Plenticore plus Manual” control, Modbus must be activated on the inverter.
For the “Kostal Smart Energy Meter Manual” control, “Enable TCP Slave” must be activated under Modbus Settings – Modbus TCP.

MYPV AC THOR, AC ELWA E Smart Energy Meter - Settings on
Kostal

When communicating with Kostal, the IP address of the inverter must not change during operation (e.g. through a DHCP router), otherwise the AC•THOR or the AC ELWA-E will lose the control signal!

Settings on AC•THOR or AC ELWA-E

For the AC•THOR, select “Kostal PIKO IQ Plenticore plus Manual” or “Kostal Smart Energy Meter Manual” for the control type either on the display or in the web interface. The IP address of the signal source must then be statically specified on the display under “Ctrl IP”.

MYPV AC THOR, AC ELWA E Smart Energy Meter -
parameters

Alternatively, these settings can also be made on the AC•THOR via the web interface. In the web setup, the parameters “Device ID” and “Device Port” can also be set by Kostal.
For the “Kostal PIKO IQ Plenticore plus Manual” control, my-PV has preset device ID 71 and device port 1502.
For the “Kostal Smart Energy Meter Manual” control, my-PV presets device ID 1 and device port 502.
With the AC ELWA-E, configuration is only possible in the web setup.

MYPV AC THOR, AC ELWA E Smart Energy Meter -
configuration

“Power timeout” is not to be changed.
If there is a battery storage unit in the system and it is to be charged with priority, then the “target value of the control” should be set to -150 W. Otherwise, we recommend leaving -50 W.

Subject to change. my-PV GmbH
Betriebsstrasse 12, 4523 Neuzeug
www.my-pv.com
AC•THOR®or AC ELWA® -E with Kostal