The HELLA product is a high-quality product with the latest technology that is easy to install and operate.
These instructions provide information on the basic installation, commissioning, and use of the product.
The product is designed for outdoor blinds and exterior Venetian blinds.

Symbols Used

  • Attention! – Indicates instructions that, if disregarded, can put the user in danger.
  • Attention! – Indicates instructions that, if disregarded, can potentially result in damage to the product.
  • Instructions for use or helpful information.
  • Requires action.
  • Attention! – Indicates a risk of injury or danger to life due to an electric shock.
  • Indicates parts of the product with important information in the installation instructions.
  • Attention! – Indicates a possible risk of injury by crushing.
  • Indicates cleaning of the product.
  • Indicates maintenance and repair of the product.

Product Usage Instructions

Before Installation

  1. Check the product immediately for possible shipping damage and compliance with the delivery receipt.
  2. If parts are missing or damaged, consult your supplier immediately.
  3. Check the mounting base and ensure that the mounting material complies with the given conditions for proper installation.
  4. If unsure, seek advice from a specialist enterprise for fixing techniques.
  5. Protect the packaging cardboard box from humidity during transport.
  6. Carry larger units by two persons to prevent injury and damage to the product.
  7. Remove the packaging material carefully, avoiding damage to the contents.
  8. Dispose of the packaging material via recycling.
  9. Close off the place of installation and use suitable ascent supports, scaffoldings, and fall protection devices when working at higher heights.
  10. Ensure that ascent supports stand solidly and provide a firm grip.

Tools for Installation

  • Battery-powered drill
  • Bit extension (depending on the mounting base)
  • Drill set according to the mounting base
  • Bit holder AF 3/8 inch
  • Level
  • Measuring tape
  • Pin
  • Torx screwdriver TX25 (AW20 also possible)
  • Allen key 4 mm

Preliminary remarks HELLA Model aluminum duct with screen – VA or with plaster base – VAP

  • With this HELLA product, you have opted for a high-quality product with the most up-to-date technology that can nevertheless be easily installed and operated. In these instructions, we describe the basic installation, commissioning, and use.
  • For authorized specialist staff
  • For the consumer (user)
  • Please refer to the enclosed installation instructions and instructions for the use of outdoor blinds & exterior Venetian blinds for additional information and notes regarding HELLA outdoor blinds & exterior Venetian blinds.

symbols

The following symbols will assist you with the installation or use and require safety-conscious conduct:

Attention!

  • This symbol indicates instructions that, if disregarded, can put the user in danger.

Attention!

  • This symbol indicates instructions that, if disregarded, can potentially result in damage to the product.
  • This symbol indicates instructions for use or helpful information.

Attention!

  • This symbol indicates a risk of injury or danger to life due to an electric shock.
  • This symbol indicates parts of the product, for which you will find important information in these installation instructions.

Attention!

  • This symbol indicates a possible risk of injury by crushing.
  • This symbol indicates the cleaning of the product.
  • This symbol requires you to act.
  • This symbol indicates the maintenance and repair of the product.

Before installation

  • Check the product immediately for possible shipping damage and for compliance with the delivery receipt.
  • If parts are missing or damaged, please consult your supplier immediately.
  • Check the mounting base and ensure that the mounting material to be used complies with the given conditions to guarantee proper installation. In case of doubt, please seek advice from a specialist enterprise for fixing techniques.
  • The packaging cardboard box should not be exposed to humidity. To protect it from rain during transport, it should be covered by a foil.
  • Carry larger units by two persons. Transport and store the units carefully to prevent injury of persons and damage to the product.
  • Remove the packaging material carefully. When using a knife, be careful not to damage the packaging content and to avoid cuts!
  • Dispose of the packaging material via recycling.

Caution!

  • A wrong installation can endanger the user seriously. Please strictly observe the installation instructions. Close off the place of installation.
  • When working at higher heights, there is the risk of falling. Suitable ascent supports, scaffoldings, and fall protection devices are to be used. Please make sure that the ascent supports stand solidly and provide a firm grip.

Overview

Tools for the installationHELLA-Aluminium-Duct-with-Screen-VA-Or-with-
Plaster-Base-VAP-fig-10

Model aluminum duct with screen – VA or with plaster base – VAPHELLA-
Aluminium-Duct-with-Screen-VA-Or-with-Plaster-Base-VAP-
fig-11

Legend

  1. Aluminum duct
  2. Lateral covering
  3. Sealing profile
  4. Covering cap for guide rail
  5. End cap for the bottom rail
  6. Bottom rail
  7. Slat
  8. Lift tape
  9. Ladder cord
  10. Guide rail
  11. Guide rail insert

Type overview Model aluminum duct with screen angular – VA7

HELLA-
Aluminium-Duct-with-Screen-VA-Or-with-Plaster-Base-VAP-
fig-12

Model aluminum duct with screen chamfered – VA9HELLA-Aluminium-Duct-with-
Screen-VA-Or-with-Plaster-Base-VAP-fig-13

Standard duct dimensions:

  • KT = 120 mm / 150 mm / 160 mm
  • H = 200 mm / 240 mm / 280 mm
  • RV = 20 mm, upon request from 3 mm to 60 mm
  • DK = 20 mm / 40 mm.

Legend

  • KT Channel depth
  • H Channel height
  • RV Rear shortening
  • DK Insulation body

Type overview Model aluminum duct with plaster base – VAPHELLA-Aluminium-
Duct-with-Screen-VA-Or-with-Plaster-Base-VAP-fig-14

Standard duct dimensions:

  • KT = 110 mm / 140 mm / 150 mm
  • H = 200 mm / 240 mm / 280 mm
  • RV = 20 mm, upon request from 3 mm to 60 mm
  • DK = 20 mm / 40 mm
  • PT = 10 mm, upon request from 20 mm or without plaster base
  • PN = 5 mm or 20 mm, special lengths between 5 mm and 80 mm (without plaster base the minimum plaster flange is 10 mm)

Legend

  • KT Channel depth
  • H Channel height
  • RV Rear shortening
  • DK Insulation body
  • PT Plaster base
  • PN Plaster flange

Installation in general

HELLA-Aluminium-Duct-with-Screen-VA-Or-with-Plaster-Base-VAP-
fig-15

Check the dimensions of the element and wall opening, and the dimension of the window respectively. Measure the dimension of the cable duct for the drive system at the box and provide the appropriate wall or window duct.

  1. Push the guide rails onto the struts until the stop position is reached. Do not damage the slat guiding nipples. Make sure that the guide rails are at the same height.
  2. Screw down the countersunk screws to fix the box to the guide rail.
  3. Hold the unit to the mounting base, adjust it, and mark the boreholes through the guide rails on the mounting base.
    • Provide the boreholes according to the mounting material to be used. Put the motor cable through the wall or window duct already provided and fix the element to the structure.
  4. Place the covering caps in the boreholes in the guide rails.

Legend

  • Countersunk screw M5 x 16 mm
  • FB Complete width
  • LB Clear width
  • LL Slat length
Installation of the guide rail insert
  • Press the guide rail insert into the chamber of the guide rail.
  • Move the guide rail insert over the slat guiding nipples towards the top. (A slight bending of the guide rail insert eases the installation.)
  • All slat guiding nipples must be placed inside the guide rail insert.
  • The recess areas in the guide rail insert must be at the bottom side. (Locking with pins of the guide rail covering cap.)

Mounting the installation lug

  • The enclosed fastening lugs serve as an additional safeguard of the plaster base box and suppress the formation of cracks in the plaster.
  • Depending on the installation situation, screw the installation lugs to the box and the surrounding brickwork.
  • Lift the box slightly at the front before mounting the installation lug.
  • If the installation lug is bended, mount the self-drilling head screw and the screw for the mounting base as near as possible to the wrapping of the installation lug.
  • The distance between the self-drilling head screw and the upper edge of the box should be as small as possible.

Legend

  1. Mounting lug
  2. Dowel SX 8
  3. Pan head screw ø4.5×50 mm
  4. Self-drilling head screw with collar ø4.2×16 mm

Installation of insect screen rail for integrated moscita insect roller screen

The insect screen is already pre-assembled in the plaster base box.

With motor drive

Installation of the insect screen according to the enclosed installation instructions for outdoor blinds / exterior Venetian blinds. (Chapter “Installation guide rail FUP70 / FUP80 / FUP95 installation insect screen”)

With crank handle drive

Do not remove the tear tape from the guide rail!

  • Screw down the insect screen guide rail laterally through the drilled holes to the guide rail FUP95. Fix the insect screen rail in such a way that it is flush with the lower edge of the guide rail.
  • 1 self-drilling head screw/bore hole in the insect screen rail

Legend

  1. Tear tape
  2. Self-drilling head screw ø4.2×22 mm

Installation Easy-Click see accompanying installation instructions for outdoor blinds / exterior Venetian blinds.

Commissioning/functional check

  • Extend and retract the unit in and out completely. When extending the unit for the first time, make sure no one is in the operating radius or standing below the unit.
  • Make sure that during the later operation, the units can be extended freely and without blocking. Do not extend the unit, if objects or persons are in the operating radius of the sun protection unit. Please observe the safety instructions.
  • After the first extension check the mounting material and the construction elements for strength.
  • Automatic control devices or switches, that are not in the operator’s field of vision, may not be used for test runs of motor-driven units.
  • We recommend the use of a test cable for the provisional operation of the motor.
  • Check all settings.
  • Check all screwed connections for tightness.
  • Double-check the grip of the supports on the mounting base.

Attention!

  • Insufficient fastening of the mounting brackets can cause the collapse of the unit; there is a risk of injury or danger to life!
  • Clean the elements (see maintenance instructions).
  • Pass these instructions as well as possible instructions of the motor, switch, and control manufacturer on to the user.
  • Brief the user, whereupon you provide comprehensive information on the safety and user instructions of the system.
  • Have the correct design of the system as well as the installation and briefing with the safety information confirmed in writing (see handover report).

Removal

  • Switch the unit dead and take safety precautions against unintentional switching on.
  • The removal is carried out in reverse order to the installation.

Installation InstructionsHELLA-Aluminium-Duct-with-Screen-VA-Or-with-
Plaster-Base-VAP-fig-21

  • For questions, wishes, and ideas:
  • HELLA Infoline +43/(0)4846/6555-0
  • HELLA Sonnen- und Wetterschutztechnik GmbH
  • A-9913 Abfaltersbach, No. 125
  • Phone: +43/(0)4846/6555-0
  • Fax: +43/(0)4846/6555-134
  • e-mail:office@hella.info
  • Internet: http://www.hella.info

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals