Product Information

Specifications

  • Material: Aluminium alloy
  • Safety Class: I
  • Protection Class: IP 65
  • Impact Strength: IK06
  • Energy Efficiency Class: E
  • Power Consumption: 0.07 A
  • Lamp Module Connected Wattage: 12 W
  • Luminaire Connected Wattage: 14 W
  • Colour Temperature: 3000 K
  • Colour Rendering Index: CRI > 90
  • Luminaire Luminous Flux: 1265 lm
  • Luminaire Luminous Efficiency: 90.4 lm / W

Product Usage Instructions

  • This luminaire requires a separate mains plug for connection to the power source. Various country-specific mains plugs with a 0.5m connecting cable are available as accessories.
  • Follow national safety regulations for installation and operation. Do not modify the luminaire without proper authorization as it may result in damage or safety hazards.
  • The luminaire’s electronic components are protected against overvoltage according to DIN EN 61547. For additional protection against transients, consider using separate overvoltage protection components.
  • Ensure that the total power consumption does not exceed 6 A when configuring your lighting system. The power consumption of the 85 172 model is 0.07 A.

FAQ

  • Q: What should I do if I need to connect the floodlight to the mains?
  • A: You will need to order a separate mains plug, available with country-specific options and a 0.5m connecting cable.
  • Q: How can I protect the electronic components of the luminaire against overvoltage?
  • A: The luminaire already has overvoltage protection according to DIN EN 61547. For additional protection, consider using separate overvoltage protection components available on the manufacturer’s website.
  • Q: Is it safe to modify the luminaire?
  • A: Modifying the luminaire may void the warranty and pose safety risks. Only authorized personnel should make modifications to the product.

Dimension

BEGA-85-172-Performance-Floodlight-fig-1Instructions for use

Application

  • Performance floodlight BEGA UniLink® with connection adapter for use in combination with various accessories, e.g. for mounting on trees, pipes or wooden structures.
  • A separate mains plug must be ordered to connect the floodlight to the mains.
  • The various country-specific mains plug with 0.5 m connecting cable, as well as extension cables and five-way distribution boxes are available as accessories.

Product Description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Colour graphite or silver
  • Clear safety glass
  • Silicone gasket
  • Reflector surface is made of pure aluminium
  • Optical silicone lens · BEGA Hybrid Optics®
  • Rotation range of floodlight 360°
  • Swivel range -30°/+70° 5 m mains supply cable
  • X05RN-F FEP 2 × 1@ + 1G2,5@ with BEGA UniLink® plug-in connector
  • Complies with flicker requirements by IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit 220-240 V 50/60 Hz
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Impact strength IK06
  • Protection against mechanical impacts < 1 joule
  •  – Conformity mark
  • Weight: 1.6 kg
  • This product contains light sources of energy efficiency class(es) E

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage under DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at  www.bega.com.
  • The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.

Total load

  • When configuring your lighting system, please ensure that the maximum power consumption of 6 A is not exceeded.
  • Information on power consumption can be found in the instructions for use and data sheets for all BEGA UniLink® luminaires.
  • Power consumption of 85 172: 0,07 A

Lamp

  • Module connected wattage 12 W
  • Luminaire connected wattage 14 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 50 °C

85 172 K3

  • Module designation LED-1148/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1730 lm
  • Luminaire luminous flux 1265 lm
  • Luminaire luminous efficiency 90,4 lm / W

85 172 K4

  • Module designation LED-1148/940
  • Colour temperature 4000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1815 lm
  • Luminaire luminous flux 1327 lm
  • Luminaire luminous efficiency 94,8 lm / W

Lighting technology

  • Symmetrical wide beam light distribution Half beam angle 45°
  • For special lighting applications, the symmetrical light cone can be changed to a flat beam using an additional diffuser lens.

Caution

  • The BEGA UniLink® plug connectors may only be connected and disconnected in a voltage-free state.

Installation

  • Unscrew the hexagon socket screws (wrench size 3 mm) on the sides of the connection adapter and screw the corresponding accessory to the floodlight.
  • Torque = 5 Nm.
  • Plug the floodlight’s connecting cable into the plug contact of the connecting cable with the country-specific mains plug or into the distribution box or extension cable.
  • To ensure a sufficiently low protective conductor resistance (loop resistance), the connecting cable of each luminaire in the system must not exceed a length of 50 m from the entry point.
  • Adjustment of beam direction:
  • Undo the joint screw (hexagon socket head wrench size 5 mm) and set the desired beam direction.
  • Tighten the joint screw.
  • Torque = 7 Nm.

Cleaning And Maintenance

  • Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high-pressure cleaners.

Maintenance
The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.

Please note

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Replacing the LED module

  • The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
  • Disconnect the system from the power supply.
  • Open the floodlight:
  • Remove the trim ring along with the safety glass and reflector by twisting it anti-clockwise.
  • Replace the LED module.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Place the trim ring with glass and reflector on the floodlight housing so that the notches in the trim ring and luminaire housing sit on top of each other.
  • Twist on the trim ring clockwise as far as the stop.

Accessories
The following combination options are available for fitting to floodlights with connection adapter

  • 71 223 Screw clamp with connection adapter
  • 71 224 Tube clamp with connection adapter
  • 71 225 Lashing straps with connection adapter
  • 71 226 General fasteners with connection adapter
  • 71 227 G½ mount with connection adapter Shields and diffuser lenses that alter the light distribution are available as accessories for these floodlights.
  • 71 289 Exchangeable lens flat beam
  • 71 331 Shield
  • 71 335 Cylindrical shield Country-specific mains plugs with 0.5 m connecting cable
  • 71 180 Plug type F / E: system common in Germany and Europe
  • 71 181 Plug type G: system used in Great Britain (“Commonwealth plug”)
  • 71 182 Plug type J: system common in Switzerland and Liechtenstein
  • 71 183 Plug type L: system common in Italy and Greece
  • 71 184 Plug type K: system common in Denmark and Greenland BEGA UniLink® extension cables with socket and plug
  • 71 186 BEGA UniLink® Extension cable 5 m
  • 71 187 BEGA UniLink® Extension cable 10 m
  • 71 188 BEGA UniLink® Extension cable 20 m BEGA UniLink® connecting cables with a plug connector and one free cable end to connect to e.g. a conventional connection box
  • 71 247 Connecting cable 5 m with free line ends
  • 71 256 Connecting cable 0.5 m with free line ends BEGA UniLink® distribution box with five connection sockets for the connection of BEGA UniLink® luminaires, extension cables or additional five-way distribution boxes
  • 71 189 BEGA UniLink® Five-way distribution box

For the accessories, separate instructions for use can be provided upon request.

Spares

  • Trim ring graphite with glass 25 000 273
  • Trim ring silver with glass 25 000 274
  • LED power supply unit DEV-0475/350
  • LED module 3000 K LED-1148/930
  • LED module 4000 K LED-1148/940
  • Reflector 75 005 131
  • Gasket housing 83 000 486
  • Gasket trim ring 83 002 169

CONTACT

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals