Product Information
Specifications
- Material: Aluminium alloy
- Safety Class: I
- Protection Class: IP 65
- Impact Strength: IK06
- Energy Efficiency Class: E
- Power Consumption: 0.07 A
- Lamp Module Connected Wattage: 12 W
- Luminaire Connected Wattage: 14 W
- Colour Temperature: 3000 K
- Colour Rendering Index: CRI > 90
- Luminaire Luminous Flux: 1265 lm
- Luminaire Luminous Efficiency: 90.4 lm / W
Product Usage Instructions
- This luminaire requires a separate mains plug for connection to the power source. Various country-specific mains plugs with a 0.5m connecting cable are available as accessories.
- Follow national safety regulations for installation and operation. Do not modify the luminaire without proper authorization as it may result in damage or safety hazards.
- The luminaire’s electronic components are protected against overvoltage according to DIN EN 61547. For additional protection against transients, consider using separate overvoltage protection components.
- Ensure that the total power consumption does not exceed 6 A when configuring your lighting system. The power consumption of the 85 172 model is 0.07 A.
FAQ
- Q: What should I do if I need to connect the floodlight to the mains?
- A: You will need to order a separate mains plug, available with country-specific options and a 0.5m connecting cable.
- Q: How can I protect the electronic components of the luminaire against overvoltage?
- A: The luminaire already has overvoltage protection according to DIN EN 61547. For additional protection, consider using separate overvoltage protection components available on the manufacturer’s website.
- Q: Is it safe to modify the luminaire?
- A: Modifying the luminaire may void the warranty and pose safety risks. Only authorized personnel should make modifications to the product.
Dimension
Instructions for use
Application
- Performance floodlight BEGA UniLink® with connection adapter for use in combination with various accessories, e.g. for mounting on trees, pipes or wooden structures.
- A separate mains plug must be ordered to connect the floodlight to the mains.
- The various country-specific mains plug with 0.5 m connecting cable, as well as extension cables and five-way distribution boxes are available as accessories.
Product Description
- Luminaire made of aluminium alloy, aluminium and stainless steel
- BEGA Unidure® coating technology
- Colour graphite or silver
- Clear safety glass
- Silicone gasket
- Reflector surface is made of pure aluminium
- Optical silicone lens · BEGA Hybrid Optics®
- Rotation range of floodlight 360°
- Swivel range -30°/+70° 5 m mains supply cable
- X05RN-F FEP 2 × 1@ + 1G2,5@ with BEGA UniLink® plug-in connector
- Complies with flicker requirements by IEEE 1789,
- DIN IEC/TR 63158, DIN IEC/TR 61547-1
- LED power supply unit 220-240 V 50/60 Hz
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets
- Impact strength IK06
- Protection against mechanical impacts < 1 joule
- – Conformity mark
- Weight: 1.6 kg
- This product contains light sources of energy efficiency class(es) E
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage under DIN EN 61547.
- To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
- The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.
Total load
- When configuring your lighting system, please ensure that the maximum power consumption of 6 A is not exceeded.
- Information on power consumption can be found in the instructions for use and data sheets for all BEGA UniLink® luminaires.
- Power consumption of 85 172: 0,07 A
Lamp
- Module connected wattage 12 W
- Luminaire connected wattage 14 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 50 °C
85 172 K3
- Module designation LED-1148/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 1730 lm
- Luminaire luminous flux 1265 lm
- Luminaire luminous efficiency 90,4 lm / W
85 172 K4
- Module designation LED-1148/940
- Colour temperature 4000 K
- Colour rendering index CRI > 90
- Module luminous flux 1815 lm
- Luminaire luminous flux 1327 lm
- Luminaire luminous efficiency 94,8 lm / W
Lighting technology
- Symmetrical wide beam light distribution Half beam angle 45°
- For special lighting applications, the symmetrical light cone can be changed to a flat beam using an additional diffuser lens.
Caution
- The BEGA UniLink® plug connectors may only be connected and disconnected in a voltage-free state.
Installation
- Unscrew the hexagon socket screws (wrench size 3 mm) on the sides of the connection adapter and screw the corresponding accessory to the floodlight.
- Torque = 5 Nm.
- Plug the floodlight’s connecting cable into the plug contact of the connecting cable with the country-specific mains plug or into the distribution box or extension cable.
- To ensure a sufficiently low protective conductor resistance (loop resistance), the connecting cable of each luminaire in the system must not exceed a length of 50 m from the entry point.
- Adjustment of beam direction:
- Undo the joint screw (hexagon socket head wrench size 5 mm) and set the desired beam direction.
- Tighten the joint screw.
- Torque = 7 Nm.
Cleaning And Maintenance
- Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
- Do not use high-pressure cleaners.
Maintenance
The connecting cable must be checked for external damage and may only be
replaced by a qualified electrician.
Please note
- Do not remove the desiccant bag from the luminaire housing.
- It is needed to remove residual moisture.
Replacing the LED module
- The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
- Disconnect the system from the power supply.
- Open the floodlight:
- Remove the trim ring along with the safety glass and reflector by twisting it anti-clockwise.
- Replace the LED module.
- Please follow the installation instructions for the LED module.
- Inspect and, if necessary, replace the luminaire gaskets.
- Defective glass must be replaced.
- Place the trim ring with glass and reflector on the floodlight housing so that the notches in the trim ring and luminaire housing sit on top of each other.
- Twist on the trim ring clockwise as far as the stop.
Accessories
The following combination options are available for fitting to floodlights
with connection adapter
- 71 223 Screw clamp with connection adapter
- 71 224 Tube clamp with connection adapter
- 71 225 Lashing straps with connection adapter
- 71 226 General fasteners with connection adapter
- 71 227 G½ mount with connection adapter Shields and diffuser lenses that alter the light distribution are available as accessories for these floodlights.
- 71 289 Exchangeable lens flat beam
- 71 331 Shield
- 71 335 Cylindrical shield Country-specific mains plugs with 0.5 m connecting cable
- 71 180 Plug type F / E: system common in Germany and Europe
- 71 181 Plug type G: system used in Great Britain (“Commonwealth plug”)
- 71 182 Plug type J: system common in Switzerland and Liechtenstein
- 71 183 Plug type L: system common in Italy and Greece
- 71 184 Plug type K: system common in Denmark and Greenland BEGA UniLink® extension cables with socket and plug
- 71 186 BEGA UniLink® Extension cable 5 m
- 71 187 BEGA UniLink® Extension cable 10 m
- 71 188 BEGA UniLink® Extension cable 20 m BEGA UniLink® connecting cables with a plug connector and one free cable end to connect to e.g. a conventional connection box
- 71 247 Connecting cable 5 m with free line ends
- 71 256 Connecting cable 0.5 m with free line ends BEGA UniLink® distribution box with five connection sockets for the connection of BEGA UniLink® luminaires, extension cables or additional five-way distribution boxes
- 71 189 BEGA UniLink® Five-way distribution box
For the accessories, separate instructions for use can be provided upon request.
Spares
- Trim ring graphite with glass 25 000 273
- Trim ring silver with glass 25 000 274
- LED power supply unit DEV-0475/350
- LED module 3000 K LED-1148/930
- LED module 4000 K LED-1148/940
- Reflector 75 005 131
- Gasket housing 83 000 486
- Gasket trim ring 83 002 169
CONTACT
- BEGA Gantenbrink-Leuchten KG
- Postfach 31 60
- 58689 Menden
- info@bega.com
- www.bega.com