ZKTeco G4 Pro Series Locker Pad
Specifications
- Dimensions: 264.45mm x 119.95mm x 54.86mm
- Features: LED, Visible light camera, IR camera, IR LED, 7 Inch HD capacitive touch screen, Speaker, Microphone, QR code sensor, Fingerprint sensor, Card reader, Reset button, USB port, Ethernet port, Tamper switch
- Power Input : 5V Auxiliary D- input
- Connectivity: RS485, Wiegand in/out, USB, Ethernet
Product Usage Instructions
Lock Control Board Address Code Settings:
Ensure the correct settings for the lock control board address code based
on the Board ID and Lock Range Switch settings provided in the manual.
Wiegand Input Connection:
Connect the Wiegand Reader to the designated Wiegand In Port following the
provided pin configuration for +12V, GND, IWD0, IWD1, WD0, WD1.
Power Connection:
Connect the power supply to the device using the recommended GND and 12V DC
input.
Parameter Settings:
Adjust the default parameter settings according to your requirements such
as allowing visitors to use, sharing compartments, halfway out options,
Wiegand format, input bits, compartment size, and number of compartments.
Storage and Pick-up:
Utilize the storage process by selecting the desired compartment type after
authentication for automatic unlocking. During pick-up, choose between ‘All
Out’ or ‘Halfway Out’ based on administrator settings.
View Records:
Access device settings to view records by navigating to [Settings] >
[Record].
FAQ
-
What should I do if the compartment cannot be unlocked after verification?
Check whether the lock control board address code is set correctly as per the provided instructions in the manual. -
Can I customize the parameter settings further?
Yes, you can adjust additional settings beyond the basic parameters mentioned in the document by referring to the user manual for detailed instructions.
Overview
RS485 conection of lock control board
LockerPad-G4 Pro can supply electricity to one lock control. If two or more lock control board is in use, the lock control boards need to be powered by independent power.
Lock Control Board Address Code Settings
Board ID | Lock Range | Switch 1 | Switch 2 | Switch 3 | Switch 4 |
---|---|---|---|---|---|
1 | 1-12 | 1 | 0 | 0 | 0 |
2 | 13-24 | 0 | 1 | 0 | 0 |
3 | 25-36 | 1 | 1 | 0 | 0 |
4 | 37-48 | 0 | 0 | 1 | 0 |
5 | 49-60 | 1 | 0 | 1 | 0 |
6 | 61-72 | 0 | 1 | 1 | 0 |
7 | 73-84 | 1 | 1 | 1 | 0 |
8 | 85-96 | 0 | 0 | 0 | 1 |
Notice: Notice: When the Compartment cannot be unlocked after verication, or the lock is unlocked incorrectly, please check whether the lock control board address code is set correctly.
Wiegand Input Connection
Power Connection
Recommended power supply
- 12V ± 10%, at least 3000mA.
- To share the power with other devices, use a power supply with higher current ratings.
Parameter Settings
Parameter Name | Default Value | Other Value |
---|---|---|
Allow Visitor to Use | Open | Close |
Allow Sharing the Compartment |
Close
|
Open
Allow Halfway Out| Open| Close
Wiegand Format
|
Wiegand26
| Wiegand26 26a; Wiegand34 34a; Wiegand36 36a; Wiegand37 37a; Wiegand50
Wiegand Input Bits| 26| 34; 36; 37; 50
Compartment Size
|
Small Compartment
| Medium Compartment Large Compartment
Number of Compartment| 12| 1-96
Notice: On this document, we just guide you the basic parameters, if you want more details about settings, please check user manual document.
Storage and Pick-up
Storage: Click this icon to enter the storage process.
When there are multiple types of compartments, the user successfully
authenticates and selects the desired type of compartment, and the compartment
is automatically unlocked.
Pick-up: Click this icon to enter the pick-up process.
- If the administrator has set “Allow Halfway Out” after clicking the pickup, the system will prompt a question asking whether to set as [All Out] or [Halfway Out].
- If the administrator does not set to Allow Halfway Out, the user can only pick up once and must take out all items at one time. Storage and Pick-up
View Records
Click > [Settings] > [Record] on the device to view the records.