kinetik WELLBEING PennyPad One Piece Self Adhesive Electric Pain Reliever Instruction Manual
- June 12, 2024
- kinetik WELLBEING
Table of Contents
- kinetik WELLBEING PennyPad One Piece Self Adhesive Electric Pain Reliever
- Assemble your PennyPad
- How to operate your PennyPad
- Battery Replacement
- Program modulation
- Applications
- Body Maps
- Maintenence & Damage
- Guidance And Manufacturer’s
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
kinetik WELLBEING PennyPad One Piece Self Adhesive Electric Pain Reliever
Assemble your PennyPad
There are only few steps of assembly required and it works as easy as the layout.
- Open battery cover with a coin.
- Flip open battery cover with a pin with care.
- Insert Battery (CR2032 only)
- Close and lock battery cover.
- Place gel pads accordingly and ready to use.
How to operate your PennyPad
- Ensure battery has been properly inserted into device
- Remove blue protective film from gel pads
- Place gel pads over correct position on back of TENS Machine
- Remove clear protective film from gel pads, do not remove gel pads from device
- Place the PennyPad onto treatment area
- Press and hold + to tum PennyPad on and activate Smart Contact Detection*
- Press + again to activate stimulation
- Use+/- to adjust stimulation level
- Automatic power off after 20 minutes
- Replace battery when PennyPad can’t be started up
Thank you for choose the Kinetik Wellbeing PennyPad. Please read these instructions for use carefully and keep them for further use.
What is PennyPad?
The Penny Pad is an innovative, One Piece Self-Adhesive electronic pain
reliever. Utilizing TENS technology to target specific pain gates. Elegantly
designed by medical grade silicone, ultra thin, flexible uni-body construction
which perfectly matches the contour of contacting surfaces. High tech
circuitry conserves energy by providing 20 minutes per treatment and up to 20
sessions per battery life. The Kinetik Wellbeing TENS machine is a safe and
easy pain management option, bringing people a brand new experience and
changing the world of pain.
What is TENS?
TENS, transcutaneous electric nerve stimulation, means electrical stimulation
of nerves through the skin. TENS is recognised as a clinically proven,
effective, non-medication method of treating pain from certain causes. It
manages pain through stopping the pain to prevent pain signals being
transmitted to the brain. It also helps to release endorphins which sooth the
treatment area by stimulating nerves. The Penny Pad is free from side-effects
when used properly, and can be used as a simple means of self-treatment. The
method is scientifically underpinned and medically approved.
Battery Replacement
Please replace battery when:
- Power off during stimulation and can’t be powered on again, or
- Can’t be powered on after a long period of storage.
Note:
- After Use
- Always place protective film back to electrode after use.
Note: Smart Contact Detection automatically detect connection. Audible
alarm will triggered when improper contacted between 2 electrodes.
When power on, stimulation level is set to 0 for safety purposes. One more
press will enter stimulation mode.
Read before you use
Pennypad should never be used to mask or relieve undiagnosed pain. Before
treating any symptoms of pain, it is mandatory to diagnose cause of pain by a
doctor.
- Product Specification Power: CR2032 Lithium 3V
- Pulse Rate: 70Hz
- Pulse Width: 200µs
- Output Voltage: Max. 65 Vpp, based on 500 0 load ±-10%
- reatment Time: 20 minutes; auto-off
- Pulse Strength : 0 – 15 stages adjustable
- Operation Environmen: 10 – 40°C, 30 – 85% Relative Humidity
- Storage Environment: – 10 – 50°C, 10 – 95% Relative Humidity
- Tranporation Environment: – 10 – 50°C, 35 – 85% Relative Humidity
- Size: 112 x 72 x 10mm
Program modulation
If you need longer treatment, please repeat operating procedure.
- There is no serviceable part content in this product.
- Replace battery when necessary.
Applications
- Back pain
- Joint pain (e.g. knee joint, hip joint, shoulder)
- Neuralgia
- Headache
- Menstrual Pain
- Pain after injuries to musculoskeletal system
- Pain with circulatory problems
- Chronic pain through various causes
Body Maps
Important Information Regarding Electro Magnetic Compatibility (Erne)
With the increased number of electronic devices such as computers and mobile
(cellular) telephones, medical devices in use may be susceptible to
electromagnetic interference from other devices. Electromagnetic interference
may result in incorrect operation of the medical device and create a
potentially unsafe situation. Medical devices should also not interfere with
other devices. In order to regulate the requirements for EMC (Electro Magnetic
Compatibility) with the aim to prevent unsafe product situations, This device
complies with European standards EN60601-1 and EN60601-1-2 (In accordance with
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC
610004-8 and IEC610004-11) and is subject to special precautionary measures
with regard to electromagnetic compatiblity.Please note that portable and
mobile HF communication systems may interfere with this unit.
- The use of Penny Pad other than those specified by Kinetik Wellbeing, with the exception of accessories sold by Kinetik Wellbeing as replacement parts for internal components, may result in increased emission or decreased immunity of the device.
- PennyPad should not be used adjacent to or stacked with other equipment. In case adjacent or stacked use is necessary, PennyPad should be observed to verify normal operation in the configuration in which it will be used. Refer to further guidance below regarding the EMC environment in which the device should be used.
Warnings
- Never use this unit near the heart, around the mouth, or on diseased skin.
- Do not use this unit in places with high humidity such as the bathroom.
- May need to use under the supervision of a physical therapist.
- For external use only.
- Long-term stimulation at the same site may cause skin discomfort. Consult a dermatologist if skin discomfort persists.
- Do not use Pennypad during the first 12 weeks of pregnancy.
- Consult a doctor before you use this device if you receive other medical treatments.
- Do not disassemble or remodel this unit.
- Do not use this unit while sleeping, driving or bathing.
- Prevent any metal object, such as belt buckle or necklace coming into contact with PennyPad.
- Supervision and medical consultancy recommended if you are under age 16.
Maintenence & Damage
- If the unit is not functioning properly or causes discomfort, stop using it immediately.
- Pause the Penny Pad before removing/moving the stimulation region.
- Use only for the specific pain problem diagnosed by professionals.
- Consult your local authorities for proper battery disposal.
- Remove battery from battery chamber if you are not going to use it for a longer period.
Guidance And Manufacturer’s
Declaration – Electromagnetic Emissions
This device is intended for use in the electromagnetic environment specified
below. The user of this device should make sure it is used in such an
environment.
Declaration – Electromagnetic Immunity
This device is intended for use in the electromagnetic environment specified
below. The user of this device should make sure it is used in such an
environment. (IEC 60601-1-2, Table 2)
Recommended Separation Distances Between Portable And Mobile Rf
Communications Equipment And This Device
This device is intended for use in an electromagnetic environment in which
radiated RF disturbances are controlled. The customer or the user of this
device can help prevent electromagnetic interference by maintaining a minimum
distance between portable and mobile RF communications equipment
(transmitters) and this device as recommended below, according to the maximum
output power of the communications equipment. IEC 60601-1-2, Table 6
or transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where Pis the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
- Note 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
- Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people.
HIVOX BIOTEK B. V.LR Veldhoven, Netherlands