DATALOGIC MX-E45 Industrial Vision Processor Instruction Manual

June 17, 2024
DATALOGIC

DATALOGIC MX-E45 Industrial Vision Processor

Product Information

Specifications

  • Product Name: MX-E25/45 Industrial Vision Processor with PNP (sourcing) I/O
  • Keyboard/Mouse: USB 3.0
  • Digital I/O: 37-pin D-Sub
  • Ethernet Ports: 2
  • Serial Port : COM 1 x RS-232
  • Monitor Output: Display Port, DVI-I
  • Power Connector: +24VDC Supply Plus GND Functional Ground* -24VDC Supply Minus

Product Usage Instructions

Supply Voltage Connection

Connect the power connector using a conductor with a minimum 2.5mm2 cross- section. The power connector should be connected as follows:

  • Connect the +24VDC supply to the plus terminal.
  • Connect the functional ground (GND) to the ground terminal.
  • Connect the -24VDC supply to the minus terminal.

HASP KEY USB PORT

To enable cameras and licenses, insert the provided Hasp key into the USB port labelled USB5, located behind the front cover of the product.

Status LEDs and Buttons

The product has the following LEDs and buttons:

  • Power LED: Green
  • HDD LED: Yellow
  • Link LED: Yellow
  • Run LED: Green
  • Power Button: Press and release to turn on/off the unit. Press and hold to force shutdown.
  • Reset Button: Triggers a hardware and PCI reset.

Communications

The camera communication uses a Cat6 Ethernet cable and provides power over Ethernet (POE) for M1xx and E1xx cameras. Only use Datalogic-provided cables for this purpose.

Digital I/O Cables Terminals and Connections

The digital I/O connections are made using a 37-pin D-Sub connector. The pin/terminal numbers and colour codes are as follows:

Pin/Terminal Number Color Code Signal Name
1 Black Input Minus (Note 1)
2 Brown Input 1- and Event 1-

I/O Configuration

The Vision Program Manager (VPM) software installed on the processor is used to create vision programs and configure input and output responses. Please refer to the Impact Reference Guide for programming details.

Camera Cables and Terminals Configuration

The camera trigger and strobe output are provided by an external 6-pin I/O cable with no connection to the Industrial Vision Processor. You can use either cable 606-0672-xx (unterminated) or cable 606-0674-xx (with terminal block 661-0399 or 248-0140). Please refer to the MX-E Series Hardware Guide for more information.

FAQ

  • Q: How do I connect the power supply to the MX-E25/45 Industrial Vision Processor?
  • A: Connect the +24VDC supply to the plus terminal, connect the functional ground (GND) to the ground terminal, and connect the -24VDC supply to the minus terminal using a conductor with a minimum 2.5mm2 cross-section.
  • Q : How do I enable cameras and licenses?
  • A : Insert the provided Hasp key into the USB port labelled USB5, located behind the front cover of the product.
  • Q : How do I turn on/off the MX-E25/45 Industrial Vision Processor?
  • A : Press and release the power button to turn on/off the unit. Press and hold the power button to force shutdown.
  • Q: How do I configure the input and output response of the MX-E25/45 Industrial Vision Processor?
  • A: Use the Vision Program Manager (VPM) software installed on the processor to create vision programs and configure input and output response. Refer to the Impact Reference Guide for programming details.

DESCRIPTION

This guide covers MX-E25/45 Industrial Vision Processor models that contain the letter “P”. For example MX-E25-P-2. These models provide PNP (sourcing) inputs and outputs. MX-E25/45 offer the most powerful and flexible way to solve even complex machine vision applications.

  • Rugged IP20 housing
  • Low Maintenance
  • 16 Inputs and 16 Outputs
  • Up to 4 GigE cameras
  • Easily Accessed connectors

SYSTEM SPECIFICATIONS

Industrial Vision Processors

  • MX-E25: Intel Celeron 1.7 GHz, 2 cores
  • MX-E45: Intel Celeron 2.4 GHz, 2 cores

Storage
128 GB SSD GigE camera ports

  • MX-E25-2/MX-E45-2: 2 ports (all are PoE capable)
  • MX-E25-4/MX-E45-4: 4 ports (all are PoE capable)

All MX-E25/45 Industrial Vision Processors have the following specifications:

  • HD graphics (1920×1200)
  • 2 x 10/100/1000 Mbps Base-T Network Interface
  • Ethernet/IP, Modbus TCP, OPC, PROFINET communications supported
  • 1 x RS232 Serial port
  • 16 x Optically Isolated Digital In + 16 x Optically Isolated Digital Out
  • Microsoft Windows 10 IoT Enterprise 2016 64-bit

GENERAL VIEW

  1. USB 3.0 Keyboard/Mouse
  2. 37-pin D-Sub Digital I/O
  3. Camera connectors
  4. Ethernet 2
  5. Ethernet 1
  6. COM 1 x RS-232 Serial Port
  7. Monitor output: Display Port
  8. Monitor output: DVI-I
  9. Supply Voltage Connection

SUPPLY VOLTAGE CONNECTION

Power Connector
+ 24VDC Supply Plus GND Funcional Ground* – 24VDC Supply Minus

*Connect the ground using a conductor with a minimum 2,5mm2 cross-section

HASP KEY USB PORT

  1. Reset button
  2. USB Port Hasp Key

To enable cameras and licenses, insert the provided Hasp key in the USB port (labelled USB5), located behind the Front Cover.

STATUS LEDS AND BUTTONS

  1. Power, Green
  2. HDD, Yellow
  3. Link, Yellow
  4. Run, Green
  5. Power Button
  6. Reset Button

Power Button: Press and release to turn on the unit or shut down the OS and switch off the unit. Press and hold to switch off without OS shutdown. Reset Button: Triggers a hardware and PCI reset. The unit is restarted.\

COMMUNICATIONS

Camera communication uses a Cat6 Ethernet cable and provides POE for M1xx and E1xx cameras. Use only Datalogic-provided cables.

DIGITAL I/O CABLE TERMINALS AND CONNECTIONS

Cable     Part Number
Digital I/O 37-pin to Terminal Block 248-01 10 606-0675-xx
Digital I/O 37-pin to pigtail (remove one end) 606-0675-xx

NOTE: Do not disconnect the cable at the connector while power is on.
Pin/Terminal Number| Color Code| Signal Name
1| Black| Input Minus (Note 1)
2| Brown| Input 1- and Event 1-
3| Red| Input 2- and Event 2-
4| Orange| Input 3-
5| Yellow| Input 4-
6| Green| Input 5-
7| Blue| Input 6-
8| Purple| Input 7-
9| Gray| Input 8-
10| White| Input 9-
11| Pink| Input 10-
12| Light Green| Input 11-
13| Black/White| Input 12-
14| Brown/White| Input 13-
15| Red/White| Input 14-
16| Orange/White| Input 15-
17| Green/White| Input 16-
18| Blue/White| Output Plus (Note 2)
19| Purple/White| No Connection
20| Red/Black| No Connection
21| Orange/Black| Output 1
22| Yellow/Black| Output 2
23| Green/Black| Output 3
24| Gray/Black| Output 4
25| Pink/Black| Output 5
26| Pink/Red| Output 6
27| Pink/Blue| Output 7
28| Pink/Green| Output 8
29| Light Blue| Output 9
30| Light Blue/Black| Output 10
31| Light Blue/Red| Output 11
32| Light Blue/Blue| Output 12
33| Light Blue/Green| Output 13
34| Gray/Red| Output 14
35| Gray/Green| Output 15
36| Purple/Black| Output 16
37| Blue/Black| Output Plus (Note 2)
 | | NOTES:

1: Common Minus for input ports (External

Pin 1| Female Connector Solder Side| 12 to 24 VDC Minus)

2: Common Plus for output ports (Not an output voltage source. External 12 to 24 VDC Plus is required)

I/O CONFIGURATION

Vision Program Manager (VPM) software installed on the processor is used to create vision programs and configure input and output responses. Refer to the Impact Reference Guide for programming details.
EXAMPLE I/O CIRCUIT DIAGRAMS

DATALOGIC-MX-E45-Industrial-Vision-Processor-fig-5
CAMERA CABLES AND TERMINAL CONFIGURATION

The camera trigger and strobe output are provided by an external 6-pin I/O cable with no connection to the Industrial Vision Processor. Use cable 606-0672-xx (unterminated) or cable 606-0674-xx (with terminal block 661-0399 or 248-0140). Refer to the MX-E Series Hardware Guide.

Cable Part Number
Camera Trigger and Strobe 6-pin to Terminal Block 248-0140 or 661-0399

606-0674-xx
Camera Trigger and Strobe: 6-pin to pigtail| 606-0672-xx

MECHANICAL DIMENSIONS

DATALOGIC-MX-E45-Industrial-Vision-Processor-fig-6

TECHNICAL DATA

ELECTRICAL FEATURES

Supply voltage (Vs)| 24 VDC ± 25%
Current Consumption| Nominal: 5.5 A at 24VDC
Digital Inputs| 16 opto-isolated, see Digital I/O Specifications.
Input Current| ON: 2.0 mA or more OFF 1: 0.16 mA or less
Input Resistance| 4.7kΩ
On Current| 2.0 mA or more
Off Current| 0.16 mA or less
Response time| 200µsec
Digital Outputs| 16 opto-isolated current sourcing, see Digital I/O

Specifications.

Format| Opto-coupler isolated open emitter output
Output Voltage| 35VDC (max)
Output Current| 100mA (per channel max)
Output saturation voltage| <1V
Residual Voltage Output On| 0.5V or less (Output current ≤50mA) 1.0V or less (Output current ≤100mA)
Response time| 200µsec
Camera interface| GigE (x 2 or x4 depending on model)
USB Hardware Port| USB 2.0 front covered port for USB Hardware Key
USB Ports| 4x USB 3.0 ports for monitor, mouse and keyboard
Graphic Interface| Intel® HD (1920×1200 resolution), DVI
Host Communications:
Serial Communications| 1x RS-232 Serial Port

Ethernet

| 10/100/1000 Mbps Ethernet x 2

Ethernet/IP, Modbus, TCP, OPC, and PROFINET communications are supported.

PCI connections| 1x PCIe x8 + 1 PCI
PHYSICAL FEATURES
Dimensions| 10.03 w x 5.11 h x 10.62 d (in)

255 w x 130 h x 270 d (mm)

Weight| 2050 g
Housing material| Galvanized plate, plastic
---|---
ENVIRONMENTAL FEATURES
Temperature| Operating: 0° to +50° C (+32° to +122° F)

Storage: -20° to +60° C (-4° to +140° F)

Relative Humidity (30°)| Operating: 10 to 90%

Storage: 5 to 95%

Vibrations (EN60068-2-6)| 2 to 8 Hz: 1.75 mm amplitude /

9 to 200 Hz: 0,5 g

Shock resistance (EN60068-2-27)| 11ms (15g)
Mechanical protection (EN 60529)| IP20
SOFTWARE FEATURES
Minimum Impact Software Version Required| 12.2.2
HARDWARE FEATURES|
CPU| MX-E25: Intel Celeron 1.7 GHz, 2 cores MX-E45: Intel Celeron 2.4 GHz, 2 cores
System Memory| MX-E25/45 DDR4 RAM 8GB
Storage| 128 GB, SSD, 1 SATA slot

SUPPORT THROUGH THE WEBSITE

Datalogic provides several services as well as technical support through its website. Log on to www.datalogic.com. For quick access, from the home page click on the search icon , and type in the name of the product you’re looking for. This allows you access to download Data Sheets, Manuals, Software & Utilities, and Drawings. Hover over the Support & Service menu for access to Services and Technical Support.

PATENT

See www.patents.datalogic.com for the patent list. This product is covered by one or more of the following patents:
Utility patents: EP2517148B1, EP2649555B1, US10095951, US8888003, US8915443, US9396404, US9495607, US9798948, ZL200980163411.X, ZL201080071124.9

SEALS

The Industrial Vision Processor has seals in some areas. The seals must not be broken or removed for any reason. The sealed parts may be opened only and exclusively by Datalogic. Breakage of these seals by a customer shall result in immediate cancellation of the warranty on the entire Industrial Vision Processor.

WARRANTY

The warranty period for this product is 24 months. See General Terms and Conditions of Sales at www.datalogic.com for further details.
CE COMPLIANCE

CE marking states the compliance of the product with essential requirements listed in the applicable European directive. Since the directives and applicable standards are subject to continuous updates, and since Datalogic promptly adopts these updates, therefore the EU declaration of conformity is a living document. The EU declaration of conformity is available for competent authorities and customers through Datalogic commercial reference contacts. Since April 20th, 2016 the main European directives applicable to Datalogic products require the inclusion of an adequate analysis and assessment of the risk(s). This evaluation was carried out concerning the applicable points of the standards listed in the Declaration of Conformity. Datalogic products are mainly designed for integration purposes into more complex systems. For this reason, it is the responsibility of the system integrator to do a new risk assessment regarding the final installation.

WARNING

This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures.

FCC COMPLIANCE

Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used under the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

EAC COMPLIANCE

Customs Union: The CU Conformity certification has been achieved; this allows the Product to bear the Eurasian mark of conformity.

LEGAL NOTICES

© 2019 Datalogic S.p.A. and/or its affiliates ♦ ALL RIGHTS RESERVED. ♦ Without limiting the rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a retrieval system, or transmitted in any form or by any means, or for any purpose, without the express written permission of Datalogic S.p.A. and/or its affiliates.

  • Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S. and the E.U.
  • Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.
  • Datalogic reserves the right to make modifications and improvements without prior notification. (821006471 REV B)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals