signify C6RDL Round Downlight User Manual

June 1, 2024
signify

C6RDL Round Downlight

Specifications:

  • Product: Calculite LED 6 gen 3 C6RDL Round
    Downlight

  • Series: 6R

  • Engine Series: C6L

  • Trim Series: C6

Product Information:

The Calculite LED 6 generation 3 downlight offers excellent
performance with UniFrame for flexible installation. It provides
industry-leading visual comfort and uniform illumination, making it
suitable for open office, institution, healthcare, and retail
applications.

Product Usage Instructions:

Standard Luminaire Installation:

  1. Assemble the complete luminaire by combining the Frame, Engine,
    Trim, and optional Accessories.

  2. Ensure proper wiring and connection according to the voltage
    options.

  3. Mount the assembled luminaire securely in the desired
    location.

Flex Install Luminaire Installation:

  1. For Flex install luminaires, combine the Engine, Trim, and
    optional Accessories.

  2. Follow the voltage options for wiring and connection.

  3. Install the assembled components securely.

Specifications Details:

For detailed specifications and configurations regarding
luminaire frame, engine lumens, CRI/CCT, beam options, dimming
options, voltage options, trim aperture, style, finish, and more,
refer to the user manual or product documentation.

FAQ:

Q: Are the Accessories BAA-compliant?

A: No, the Accessories are currently not BAA-compliant. Refer to
page 2 for more information on Accessories.

Downlighting
Calculite LED 6″ gen 3 C6RDL Round Downlight

Calculite LED 6″ generation 3 provides excellent performance coupled with optimized installation flexibility via UniFrame. Industry leading visual comfort and uniform illumination make it an ideal choice for open office, institution, healthcare, and retail applications.
Standard luminaire: Complete luminaire = Frame + Engine + Trim + Accessories (optional) Flex install luminaire: Complete luminaires = Engine (F) + Trim + Accessories (optional) Buy American Act of 1933 (BAA)* Compliant luminaire: Complete luminaire = Frame-BAC + Engine-BAC + Trim-BAC * BAA compliance requires that BAC option be selected for each of frame, engine, and trim. Frame and engine will be
ordered/shipped together; trim will be ordered/shipped separately. Accessories (optional) are not currently BAA-compliant.

Project: Location: Cat.No: Type: Qty: Notes:

Frame
Series
6R

Installation

Voltage / Options

standard example: 6RN | BAC example: 6RN-BAC

6R 6″ Non-IC Round

N New construction R Remodeler

— Universal 120/277/347V EM6 Emergency, 6W Self-Test/Self-Diagnostic1
— Universal 120/277/347V

LC Chicago Plenum2 BAC Meets the requirements of the Buy American Act of 1933 (BAA)
BAC Meets the requirements of the Buy American Act of 1933 (BAA)

Engine
Series
C6L

Lumens

CRI/CCT

Beam

Dimming

Options

Voltage

Options

C6L Calculite LED 6″ gen 3

10 1000 lm 15 1500 lm 20 2000 lm 25 2500 lm 30 3000 lm 35 3500 lm 48 4800lm 60 6000 lm

927 90CRI/2700K 930 90CRI/3000K 935 90CRI/3500K 940 90CRI/4000K 950 90CRI/5000K 3 D2W 90CRI/3000K
to 1800K 4 (dim-to-warm)

N Narrow (40°) M Medium (56°) W Wide (76°)

  • See marked spacings requirements on page 9.

Z10 0-10 V 1%

—- None

U 120/277V

D2O Dim to Off 3 347V 7 (Z10 only)

L01 Lutron PEQ0 EcoSystem 0.1% (up to 2000lm)

U 120/277V

L1 Lutron LDE1 EcoSystem (500lm not available)

RA Integral Interact RF sensor 5 (enables wireless connected lighting control)

D DALI 0.1% 6

—- None LIN Linear

U 120/277V

SOL EldoLED Solo 0-10 V 0.1%

—- None

DMX Digital Multiplexing w/RDM 0.1% LIN Linear

SQR Square

U 120/277V

E Forward & Reverse Phase (up to 3000lm)

1 120 V

F Flex install7 (no frame required)
R Calculite legacy retrofit – select legacy luminaires (E & Z10 dimming only) (see pages 2 & 7)
BAC Meets requirements of the Buy American Act of 1933 (BAA)8

Trim
Series
C6

Aperture
R

Style

Finish

standard example: C6RDLCCP | BAC example: C6RDLCCP-BAC

Flange

Options

C6 Calculite LED 6″ gen 3

R Round

DL Downlight SL Shower light 9

BK Black (anodized) CL Specular clear WH White (matte)
WH White (matte)

CC Comfort clear CD Comfort clear diffuse CZ Champagne bronze

­ White (matte) P Polished (matches aperture) F Flangeless (requires CA6RFT)

­ White (matches finish) F Flangeless (requires CA6RFT)

WHAMF White (gloss antimicrobial) ­ White (matches finish)

WHAMF White (gloss antimicrobial) ­ (not applicable)

IEM6 Trim mounted EM test switch
BAC
Meets the requisites of the Buy American Act of 1933 (BAA) **

Accessories (Not currently BAA-compliant) learn more on page 2

SBA

Interact Ready System Bridge Accessory

(refer to Philips System Bridge Accessory spec sheet for options and details)

T347-75VA 347:120V step-down transformer for non-IC (N) frame only

(see page 2 for details)

6RN-NJB 6″ round non-IC frame for use with Flex (F) light engine

(provides mechanical support for rough-in construction only, no junction box)

LCEM6

Field installable Bodine BSL06 emergency battery pack (for Flex (F) light engine only, includes switch mounting plate)

7925

Sloped ceiling 6″ adapter for 6RN and 6RA frames

CA6RFT

Mud-in ring for use in 6″ round flangeless trim installations (ordered with a flangeless trim)

CAEM6

Field-installable Bodine BSL6 6W battery pack with self-test/self-diagnostic

(for new construction frames, 120-277V)

C6RVPWH IP65 Rated vandal proof matte white accessory mounts onto flangeless trims (C6RDLF) and new construction frame only

CAEM6TSCP Must be ordered with EM6 frame for remote test switch (see page 2 for details)

1. Emergency (EM6) frame is compatible with reflector mounted test switch when trim is ordered with IEM6 option code, DL style trim only (not compatible with 347V or Power over Ethernet configs). For remote mount switch, order standard trim and CAEM6TSCP mounting plate accessory.
2. Chicago Plenum (LC) frame is not available for Buy American Compliant (BAC) configurations.
3. Consult factory for 5000K CCT (50)with narrow (N) beam.
4. Dim-to-warm (D2W) available only with Z10 dimming. Narrow (N) and medium (M) beams only.
5. Linear driver profile (see page 8).
6. DALI 4800lm and 6000lm, and all RA options require linear driver configuration (see page 8).
7. Flex install option requires light engine & trim only. Up to 3500lm only. Accessory frames available. Not compatible with standard frames and associated options. Not available with Interact (RA) dimming and IEM6 trim options.

8. Failure to properly select the “BAC” suffix could result in you receiving product that is not BAA compliant product with no recourse for an RMA or refund. This BAC designation hereunder does not address (i) the applicability of, or availability of a waiver under, the Trade Agreements Act, or (ii) the “Buy America” domestic content requirements imposed on states, localities, and other non-federal entities as a condition of receiving funds administered by the Department of Transportation or other federal agencies.
9. Non-conductive flush mount lens with pre-installed gasket (matte white non-conductive flange with diffuse lens that is flush with the flange).

CalculiteLEDgen3_6in_Downlight_C6RDL 04/24 page 1 of 11

C6RDL Calculite LED 6″ gen 3
Round Downlight

Frame-in-kits
New Construction: Galvanized stamped steel for dry or plaster ceilings. Preinstalled telescoping mounting bars from 13″ to 24″. For 4′ distances, use 1/2″ EMT, 1-1/2″ x 1/2″ U or C channel.
Max ceiling thickness is 2.75″ (70 mm) including PoE frame 4.88″ (124 mm) plenum depth for installation.
Patented install Mounting frame: · Pre-installed mounting bars for fast and tool-
less installs into T-grid & hat channel ceilings. · Close-cut aperture design eliminates
possibility of gap between ceiling opening and reflector flange. · Separate wiring compartment for wiring frame to building allows inspection prior to light engine install. · Simple plug-and-play connection between frame and light engine from below ceiling.

Retrofit

· Easily updates legacy Calculite downlights to the latest LED technology. Includes light engine, trim, and driver mounted on cover plate that mounts to junction box of previous Calculite generations. Order with RH option code at end of light engine catalog number (see details on page 6).

Compatibility: Frames

Engines

With CFL S6132_series

Use Retrofit configuration C6R Trim + C6L Engine

With INC BS600_series

Use Retrofit configuration C6R Trim + C6L Engine

With LED C6L_N series C6X6L_N series P6RDN series

Use Retrofit configuration C4R Trim + C6L Engine C6S Trim + C6L Engine C6R Trim + C6L Engine

  • Not available for retrofitting luminaires with integral emergency battery.

Emergency
Bodine BSL6 6W battery pack with self-test/ diagnostic functionality. Factory or field mounted to frame.
· For trim with integral emergency test switch, order trim with IEM6 option (ex: C6RDLCCIEM6).
· For remote ceiling mounted test switch, order standard trim (ex: C6RDLCC). Optional accessory ceiling mounting plate available (CAEM6TSCP) for remote mounted test switch.
· Refer to Calculite-LyteProfile-EasyLyte Emergency Battery Pack specification sheet for more details.

Dimming
All configurations are FCC Class A unless otherwise specified. · Advance 0-10V 1% (Z10), logarithmic curve is
standard. Specify D2O for factory-set dimto-off function, consult factory for linear dimming curve. · EldoLED SOLODrive (SOL) 0-10v 0.1% · Lutron PEQ0 (L) Hi-Lume Premier 0.1% EcoSystem · Lutron LDE1 (L01) EcoSystem 1% · Lutron LTE (LTE) Hi-Lume 2-wire phase cut 1% · Electronic low voltage (E) – forward or reverse phase dimming, Remodel and AirSeal IC Shallow are FCC Class B · DALI (D) – DT6 DALI 0.1% · DMX (DMX) – Digital Multiplexing with RDM 0.1% Dimming Options The following are factory-set options for the SOL, D, and DMX driver options (ex. DMXLIN): · SOL/D/DMX: Logarithmic (-) standard · SOL/D/DMX: Linear (LIN) · SOL/DMX: Square (SQR) · Dim to Warm (D2W): option changes CCT from 3000-1800K gradually as it dims. Use with Z10 dimming only. Fixture-to- fixture consistency of 3SDCM at 2700K & 3000K, and 5SDCM at 1800K.
Optical systems
Comfort throughout the space: True 50° physical cutoff and 45° reflected cutoff. Quality of light: 2 SDCM ensures color consistency from fixture to fixture and over the luminaire’s long lifetime. MesoOptics PET optical diffusion film: Provides a smooth beam shape and mitigates color over angle with optimized luminaire efficiency.
Light Engine
Quick connect power pack allow for easy installation and replacement from below ceiling with no need for additional wiring. This allows for: · Frame and ceiling installation to be performed
while still finalizing details such as lumen packages, CCT and control type. · Easy replacement of electronics at end of life with minimal wasted material and labor required. · Ease and upgradability of technology. · 347V light engines are Z10 dimming only and include dedicated 347V driver. For 347V non-Z10 dimming, order T347-75VA field-installed stepdown transformer accessory.

Options and Accessories
Flangeless mud-in ring: Use CA6RFT for use with flangless plaster installations. Sloped ceilings: Compatible with sloped ceiling adapters (see SCA spec sheet). C6RVPWH: includes machined aluminum ring painted white, gasketed for IP65 protection, and impact resistant polycarbonate lens (IK10). Locks in place with discrete setscrew (key included). Available also with antimicrobial fiinsh (C6RVPWHAMF). CAEM6TSCP: Ceiling cover plate for remote mounted EM6 test switch. 1/2″ (25mm) hole, 4 3/8″ (109mm) x 2 3/4″ (69mm) rectangular. Includes two mounting screws. Field install EM6 kit with Bodine BSL6 6W battery pack with self-test/self-diagnostic: Includes remote ceiling plate for test switch. To mount test switch to trim for new construction frame, order trim with IEM6 option code (e.g. C6RDLCCIEM6). Refer to Calculite-LyteProfile-EasyLyte Emergency Battery Pack specification sheet for more details. CAEM6: For use with UniFrame frame in kits. LCEM6: For use with Flex intall (F) light engines. SBA: Interact Ready System Bridge Accessory. Requires IRT9015 IR remote and Interact Pro App for commissioning. T347-75VA: Field installable 347:120V 75VA stepdown transformer, attaches to knock out on frame junction box, for use with non-IC (N) or remodel (R) frames.
ENERGY STAR® exceptions
– 90 CRI configurations – Champagne Bronze & Black finishes – 347V & Emergency voltage/options – Dali, EldoLED Solo & PoE drivers
Title 24 exceptions
– 1000lm configurations – Champagne Bronze & Black finishes
Labels and Listings
– cULus listed for wet locations – ENERGY STAR® certified – RoHS certified – CEC Title 24 JA8 certified – CCEA (frames with *LC suffix) – IP65 rated with vandal proof accessory
Warranty
5 year limited warranty Visit Signify.com/warranties for more information on Signify’s standard 5- year limited warranty on complete luminaire systems.

CalculiteLEDgen3_6in_Downlight_C6RDL 04/24 page 2 of 11

C6RDL Calculite LED 6″ gen 3
Round Downlight

AccuRender Technology (CRI 90+)
The right light brings colors to life. Our new AccuRender technology helps ensure colors are rendered more accurately and consistently, while doing so as efficiently as CRI 80 products.

Standard CRI 80
Good color rendering and high efficacy

Standard CRI 90
Better color rendering and low efficacy

AccuRender
Best color rendering, color preference and high efficacy

Enjoy design flexibility
Full range of products and options:
· Available soon in across Lightolier portfolio for application flexibility
· Multiple color temperatures (CCTs) and lumen packages offered

Promote savings
High efficacy, with no penalty: · Energy efficacy compares
well to conventional 80 CRI · Up to 25% more energy
savings vs competitor 90 CRI 1 · Helps meet Title 24 requirements

Show your true colors

Achieve color balance

High color rendering:

Best in class color consistency:

· True to life colors that help energize your environment and render better flesh tones critical for healthcare hospitality and retail applications.

· Promote aesthetic harmony in your space with 2 SDCM

· Ra up to 94 CRI · Rf up to 92 TM-30 R9 up to 67 CRI Rf,h1 up to 91 TM-30 Ga up to 99 CRI R9 up to 100 TM-30 C9 up to 94 CRI Rcs,h1 up to -5% TM-30

Round Downlight

Photometric – Downlights with CRI of 90+ & R9 of 50+

Lumen Package Beam

Flux Efficacy Beam

IES TM-30-18

(lm) (lm/W) Angle CBCP CRI R9 Rf Rg Rcs,h1 UGR

1000 lm Narrow (N) 989 115 36° 2510 90+ 50+ 91 100 -5% 0

Medium (M) 1011 116 57° 1183 90+ 50+ 91 100 -5% 0

Wide (W)

942 108 76° 641 90+ 50+ 91 100 -5% 0

1500 lm Narrow (N) 1522 119 36° 3863 90+ 50+ 91 100 -5% 1

Medium (M) 1530 117 57° 1790 90+ 50+ 91 100 -5% 1

Wide (W)

1420 109 76° 965 90+ 50+ 91 100 -5% 1

2000 lm Narrow (N) 2075 119 36° 5265 90+ 50+ 91 100 -5% 2

Medium (M) 2070 116 57° 2422 90+ 50+ 91 100 -5% 2

Wide (W)

1918 107 76° 1304 90+ 50+ 91 100 -5% 2

2500 lm Narrow (N) 2511 115 36° 6372 90+ 50+ 91 100 -5% 3

Medium (M) 2526 119 57° 2954 90+ 50+ 91 100 -5% 3

Wide (W)

2377 112 76° 1616 90+ 50+ 91 100 -5% 3

3000 lm Narrow (N) 2927 115 36° 7428 90+ 50+ 91 100 -5% 4

Medium (M) 3051 116 57° 3568 90+ 50+ 91 100 -5% 4

Wide (W)

2834 107 76° 1926 90+ 50+ 91 100 -5% 4

3500 lm Narrow (N) 3333 117 36° 8457 90+ 50+ 91 100 -5% 4

Medium (M) 3414 116 57° 3993 90+ 50+ 91 100 -5% 4

Wide (W)

3145 107 76° 2138 90+ 50+ 91 100 -5% 4

4800 lm Narrow (N) 4491 111 36° 11397 90+ 50+ 91 100 -5% 5

Medium (M) 4874 116 57° 5701 90+ 50+ 91 100 -5% 6

Wide (W)

4500 107 76° 3059 90+ 50+ 91 100 -5% 5

6000 lm Narrow (N) 5529 104 36° 14031 90+ 50+ 91 100 -5% 6

Medium (M) 6090 112 57° 7123 90+ 50+ 91 100 -5% 6

Wide (W)

5628 103 76° 3825 90+ 50+ 91 100 -5% 6

CalculiteLEDgen3_6in_Downlight_C6RDL 04/24 page 3 of 11

C6RDL Calculite LED 6″ gen 3
Round Downlight

Dimming, grouping, and zoning Bluetooth and ZigBee enabled Motion sensing and daylight harvesting Integration with 0-10V and phase dimming fixtures Code compliance Granular dimming and dwell time Correlated color temperature (CCT) tuning by switch Support for sensor-based Tunable White luminaires Energy reporting and monitoring Scheduling Demand response BMS integration (BACnet) Floor plan visualization IoT sensors for wellness IoT Apps for productivity

Standalone
New New

Option 1

Gateway Connected Option 2

Currently supported maximum system size
To be able to design the lighting system correctly for the customer, it is important to know the prime characteristics of the system, its possibilities and limitations.

System level Total number of gateways Total number of devices · Luminaires with integrated sensors · Smart TLEDS · Zones + groups Total number of ZGP devices (sensors and switches) · Sensors · Switches

Unlimited 200 per network 150 150 64
50
30 50

Group level Recommended number of lights Number of ZGP devices Number of scenes

40 (maximum 150) 5 16

Interact IOT platform

Wireless gateway

IT infrastructure

Wireless gateway

Interact Pro app

Wireless switch relay controller (plug load, relay, dimming)

Luminaires with wireless 0-10V control Phase dimming

integrated sensor

module

module

Wireless repeater and controller for exterior applicatons

Commissioning remote

Wireless wall switch

External battery Smart powered sensor LED lamp

Site & area luminaire with
sensor

Parking garage luminaire with
sensor

CalculiteLEDgen3_6in_Downlight_C6RDL 04/24 page 4 of 11

C6RDL C
Round Downlight

te LED 6″ gen 3

Wireless controls options

Interact

Radio only sensor (RA or RADIO)

Sensor bundle (IAOSB or SB)

· SWZCS is a connected sensor with integral occupancy and daylight sensing and supports wireless mesh connectivity.

· Integral RA or RADIO only sensor simply enables wireless mesh connectivity to the luminaire without any occupancy or daylight sensing.

· A wireless IoT connected lighting solution for large enterprises that span across multiple floors, buildings and require multiple gateways.

· The sensor works in the standalone mode (similar to SpaceWise) when configured without a gateway or in a cloud connected mode if a compatible gateway is used.
· Interact includes an App, a portal and a broad portfolio of wireless luminaires, lamps and retrofit kits all working on the same system.
· Startup is implemented via Interact Pro App (Android or iPhone) & BlueTooth connectivity. The App provides flexibility to choose between a gateway or non gateway mode for setup.
· Setup with the gateway requires wired internet access to the gateway. It is possible to add a gateway at a later point.
· Prepare project configuration steps remotely and use IRT9015 remote on-site to identify and group devices together.
Compatible with:
– SWS200 & UID8465 wireless scene switch
– Battery powered IP42 presence sensor OCC sensor IA CM WH 10/1
– Battery powered IP42 presence & daylight sensor OCC-DL sensor IA CM IP42 WH
– LCN3110: battery powered IP65 presence sensor, OCC sensor IA CM IP65W
– LCN3120: battery powered IP65 presence & daylight sensor, OCC-DL sensor IA CM IP65 WH
· For more information on Interact visit: interact- lighting.com/interactproscalablesystem

· Ideal for applications where sensing functionality is managed by other Interact devices and the luminaire only needs to have wireless connectivity.
· Interact includes an App, a portal and a broad portfolio of wireless luminaires, lamps and retrofit kits all working on the same system.
· Startup is implemented via Interact Pro App (Android or iPhone) & Bluetooth connectivity. The App provides flexibility to choose between a gateway or non- gateway mode for setup.
· Setup with the gateway requires wired internet access to the gateway. It is possible to add a gateway at a later point.
· Prepare project configuration steps remotely, identify and group devices together onsite.
· Compatible with SWS200 and UID8465 wireless scene switch, wireless Occ sensor (OCC SENSOR IA CM IP42 WH 10/1) and wireless Day/Occ sensor (OCC MULTI SENSOR IA CM WH 10/1).
· For more information on Interact visit: interact- lighting.com/interactproscalablesystem

· View all your projects under one dashboard and easily compare insights from multiple projects in one view.
· Compatible with SWS200 wireless scene switch, wireless Occ sensor (OCC SENSORIA CM IP42 WH 10/1) and wireless Day/Occ sensor (OCC MULTI SENSOR IA CM WH 10/1) and wireless Occupancy or Daylight & Occupancy sensors available.· Use Interact software and insights to increase building efficiency, achieve building wide integration and optimize space through occupancy analytics.
· IAOSB or SB option in addition to occupancy and daylights sensing supports advanced IoT capabilities, such as people estimation analysis, desk level temperature & humidity sensing, noise classification, and BLE beacon.
· Requires compatible Gateway and internet connectivity for commissioning.
· For more information, visit: interact-lighting.com/interactproscalablesystem
Emergency Options (ER100)
· Power Sensing (factory default) ­ Recommended UL924 option requires unswitched power sense line, absence of voltage on the normal circuit triggers luminaire to 100% output.
· Power Interruption Detection (field option) ­ Detects AC power interruption

30ms triggers 90 minute emergency mode with luminaire at 100% output.

CalculiteLEDgen3_6in_Downlight_C6RDL 04/24 page 5 of 11

C6RDL Calculite LED 6″ gen 3
Round Downlight
Polished Reflectors

Flanges

Specular clear (CL): Most specular and most efficient finish, delivers maximum photometric performance but can produce a mirror image effect of the interior space.

Champagne bronze (CZ): Semi-specular finish that softens light at the source of the reflector while providing a warmer reflector appearance (slightly warmer).

White (­): (matte) Provides the smoothest transition to ceilings when off.

Comfort clear (CC): Semi-specular finish that softens the light at the source of the reflector and creates a subtle, even luminance from the reflector cone.

White (WH): (matte) Brightest illuminated aperture and provides the smoothest transition to most ceilings when off (white is only available with a white flange).

Polished (P): (matches aperture) Produces a continuous look throughout the reflector (aperture matching).

Comfort clear diffuse (CD): Slightly diffuse clear finish, that eliminates iridescence and reduces the mirror image effect inherent with specular finishes.

Black (BK): (anodized) Specular finish that provides the lowest aperture brightness possible and significantly reduces source identification in a ceiling.

Flangeless (F): (flush-mount)Creates a flush, virtually seamless transition from aperture to ceiling.

Vandal proof (VP): Provides an elegant solution for vandal resistant needs. One piece machined aluminum ring with impact resistant clear lens. Flangeless (F) flange must be ordered. Provides the luminaire with an IK10 impact and IP65 rating.

Shower light (SL): Wet location rated shower light with clear acrylic lens applicable in any installation requiring dead front trims, interior or exterior noncorrosive applications, or where a diffused lens at the ceiling is required (non-conductive).

Mud-in ring (FT): Low profile, machined aluminum mud-in ring provides a raised rib to plaster up to and a 3/16″ flange thickness. The ring is attached to the ceiling material as opposed to the frame-in kit to avoid conduction of heat and vibration which can cause yellowing or cracking of the plaster.

CalculiteLEDgen3_6in_Downlight_C6RDL 04/24 page 6 of 11

C6RDL Calculite LED 6″ gen 3
Round Downlight

New Construction (N)
12 3/8 in 314 mm
8 1/2 in 209 mm

Emergency battery pack shown with EM6 option on new construction non-IC frame.

Chicago Plenum (LC)

1 0 1/8 in 257 mm

10 3/8 in 264 mm

13 1/4 in 337 mm
10 in 254 mm

Center point location for integral emergency
test switch (IEM6)

13 5/8 in 346 mm

6RN-NJB has the same dimensions (no junction box).

Emergency battery pack shown with EM6 option on new construction non-IC frame.

6 3/8 in 161 mm
3 ” (85 mm)

ø6 in 152 mm
ø7 3/8 in 184 mm

Ceiling Cutout ø6 3/8 in 162 mm

2 3/4 in 70 mm Maximum ceiling thickness

19 5/8 in 498 mm
14 1/2 in 368 mm

7 1/4 in 184 mm

Remodeler (R)

17 5/8 in 448 mm
12 1/4 in 312 mm (max.)

1 0 1/8 in 257 mm

Flangeless mud-in ring (CA6RFT) accessory

D
81/2 in 216 mm

63/8 in 163 mm
61/2 in 165 mm

Detail D

6 3/8 in 161 mm

ø6 in 152 mm
ø7 1/4 in 184 mm

Ceiling Cutout ø6 5/8 in 167 mm

CalculiteLEDgen3_6in_Downlight_C6RDL 04/24 page 7 of 11

Retrofit (R) with round trim

Vandal Proof (VP) accessory

6 3/8 in 161 mm
ø6 in 152 mm ø7 3/8 in 187 mm

ø5 7/8 in 149 mm
ø7 3/4 in 196 mm

3/8 in 10 mm

C6RDL Calculite LED 6″ gen 3
Round Downlight

Linear driver (RA)
Requires 19″ plenum space

Flex Install (F)

8 3/4 in
222 mm
12 in
305 mm
2 0 3/4 in
527 mm

1 5/8 in 43 mm

1 5 3/4 in 402 mm

3 1/8 in 81 mm
5 1/2 in 138 mm

2 5/8 in 68 mm

LCEM6 Flex install (F) engine only

2 in
51 mm
Dimensions for DALI 4800lm and 6000lm, and RA light engines. Sensor shown for RA light engine only.

1 1/4 in
32 mm

3 1/2 in 90 mm
5 1/2 in 140 mm
2 7/8 in 73 mm

1 1/2 in 38 mm

1 5/8 in 42 mm

  • 12″ conduit with connector to j-box knock out

CalculiteLEDgen3_6in_Downlight_C6RDL 04/24 page 8 of 11

C6RDL Calculite LED 6″ gen 3
Round Downlight

Electrical – Narrow

Light Input engine Volts
120V 1000lm 277V
347V 120V 1500lm 277V 347V 120V 2000lm 277V 347V 120V 2500lm 277V 347V 120V 3000lm 277V 347V 120V 3500 lm 277V 347V 120V 4800lm 277V 347V 120V 6000lm 277V 347V

Input Freq. 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz

THD Power Input Drive Input LED Factor Factor Current Current Power Power @ Max Load 0.072A 0.22A 8.6W 7.0W <10% >0.9 0.032A 0.22A 8.8W 7.0W <20% >0.9 0.029A 0.22A 10.0W 7.0W <30% >0.9 0.107A 0.33A 12.8W 10.7W <10% >0.9 0.046A 0.33A 12.9W 10.7W <10% >0.9 0.042A 0.33A 14.6W 10.7W <25% >0.9 0.145A 0.45A 17.4W 14.7W <10% >0.9 0.063A 0.45A 17.5W 14.7W <10% >0.9 0.056A 0.45A 19.4W 14.7W <20% >0.9 0.178A 0.55A 21.4W 18.2W <10% >0.9 0.078A 0.55A 21.5W 18.2W <10% >0.9 0.065A 0.55A 22.7W 18.2W <20% >0.9 0.212A 0.65A 25.5W 21.7W <10%

0.9 0.091A 0.65A 25.3W 21.7W <10% >0.9 0.077A 0.65A 26.7W 21.7W <15% >0.9 0.237A 0.75A 28.4W 24.4W <10% >0.9 0.103A 0.75A 28.4W 24.4W <10% >0.9 0.084A 0.75A 29.1W 24.4W <15% >0.9 0.338A 1.05A 40.5W 34.9W <10% >0.9 0.145A 1.05A 40.3W 34.9W <10% >0.9 0.118A 1.05A 41.0W 34.9W <10% >0.9 0.442A 1.35A 53.0W 45.6W <10% >0.9 0.188A 1.35A 52.1W 45.6W <10% >0.9 0.153A 1.35A 53.0W 45.6W <10% >0.9

Lifetime (TM-21) data

Lumens
1000lm 1500lm 2000lm 2500lm 3500lm* 4800lm
6000lm

Narrow beam

Medium/Wide beam

L90 @ 60,000hrs. L90 @ 60,000hrs.

L90 @ 60,000hrs. L80 @ 60,000hrs.

  • Lutron 3500lm with Medium/Wide beam is L85 @ 60,000hrs.

CCT (K)

Electrical – Medium & Wide

Light Input engine Volts
120V 1000lm 277V
347V 120V 1500lm 277V 347V 120V 2000lm 277V 347V 120V 2500lm 277V 347V 120V 3000lm 277V 347V 120V 3500 lm 277V 347V 120V 4800lm 277V 347V 120V 6000lm 277V 347V

Input Freq. 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz

THD Power Input Drive Input LED Factor Factor Current Current Power Power @ Max Load 0.073A 0.22A 8.7W 7.1W <10% >0.9 0.032A 0.22A 8.9W 7.1W <20% >0.9 0.029A 0.22A 10.2W 7.1W <30% >0.9 0.109A 0.33A 13.0W 10.9W <10% >0.9 0.047A 0.33A 13.1W 10.9W <10% >0.9 0.043A 0.33A 14.9W 10.9W <25% >0.9 0.149A 0.45A 17.8W 15.1W <10% >0.9 0.065A 0.45A 18.0W 15.1W <10% >0.9 0.057A 0.45A 19.8W 15.1W <20% >0.9 0.179A 0.55A 21.4W 18.2W <10% >0.9 0.078A 0.55A 21.6W 18.2W <10% >0.9 0.066A 0.55A 22.8W 18.2W <20% >0.9 0.220A 0.67A 26.4W 22.4W <10%

0.9 0.095A 0.67A 26.2W 22.4W <10% >0.9 0.079A 0.67A 27.5W 22.4W <15% >0.9 0.245A 0.75A 29.4W 25.3W <10% >0.9 0.106A 0.75A 29.4W 25.3W <10% >0.9 0.087A 0.75A 30.1W 25.3W <15% >0.9 0.350A 1.08A 42.0W 36.1W <10% >0.9 0.150A 1.08A 41.5W 36.1W <10% >0.9 0.122A 1.08A 42.5W 36.1W <10% >0.9 0.454A 1.38A 54.5W 46.8W <10% >0.9 0.193A 1.38A 53.5W 46.8W <10% >0.9 0.157A 1.38A 54.5W 46.8W <10% >0.9

Dim-to-Warm: CCT vs Dimmed level

3200

3000

2800

2600

2400

2200

2000

1800

1600

2% 15% 30% 50% 75% 100%
Dimming level

Marked spacing applications

Light engine C6L_Z10 series C6L_L01 series C6L_L1 series C6L_LD series

4800lm X X X X

6000lm X X X X

Light engine C6L_LTE series C6L_D series C6L_DMX series C6L_RA series

4800lm X X X X

6000lm X X X X

Modules marked with an X require marked spacing: – Center-to-center of adjacent luminaires: 24″ (610mm) – Luminaire center to side building member: 12″ (305mm)
In accordance with CAN ICES-005-A/ NEB-005-A and FCC Part 15-A.

CalculiteLEDgen3_6in_Downlight_C6RDL 04/24 page 9 of 11

C6RDL Calculite LED 6″ gen 3
Round Downlight

Narrow beam, 2500lm Engine, 115 lm/W at 22W

Candela Curve

938 1875 2313 3750

6RN / C6L25935NZ10U / C6RDLCL

Output lumens: Input watts: CRI: CCT 1: Spacing Crit.: Beam Angle:

2512 lms 21.8 W 90 min 3500K 0.6 36°

Zonal summary

Zone Lumens %Luminaire

0-30 0-40 0-60 0-90

2231 2423 2510 2512

88.8% 96.5% 99.9% 100.0%

Angle Mean CP Lumens

0

6372

5 6006

10

4997

540

15

3915

20 2643 1066

25

1335

30

514

625

35

286

40

222

192

45

107

50

12

83

55

4

60

2

4

65

1

70

1

1

75

1

80

0

0

85

0

90

0

0

Single unit data

Height to Initial center beam

Beam

lighted plane foot-candles diameter (ft)*

8′

100

4.8′

9′

79

5.4′

10′

64

6.0′

12′

44

6.6′

14′

33

8.4′

  • Beam diameter is where foot-candles drop to 50% of maximum.

Multiple unit data – RCR 2

Spacing Initial center beam

Watts

on center

foot-candles

per sq. ft.

5′

118.0

0.97

6′

77.0

0.63

7′

55.0

0.45

8′

46.0

0.38

9′

37.0

0.30

38′ x 38′ x 10′ Room, Workplane 2.5′ above floor, 80/50/20% Reflectances

Efficacy: 115.2 lm/W Report2: STMR-1590.2

Adjustment factors

Finish

CCT

CL = 100% CC = 95% CD = 87% CZ = 63% WH = 87% BK = 57%

90CRI, 4000K = 102% 90CRI, 3500K = 100% 90CRI, 3000K = 96% 90CRI, 2700K = 92%

Lumens
6000lm = 240% 4800lm = 192% 3500lm = 140% 3000lm = 120% 2500lm = 100% 2000lm = 80% 1500lm = 60% 1000lm = 40%

Coefficients of utilization

Ceiling

80%

70%

50%

30% 0%

Wall 70 50 30 10 50 10 50 10 50 10 0

Room Cavity Ratio

RCR
0 1 2 3 4 5 6 7 8 9 10

Zonal cavity method – Effective floor reflectance = 20%
119 119 119 119 116 116 111 111 106 106 100 114 112 110 108 110 106 106 103 102 100 95 110 106 102 100 104 99 101 96 98 94 91 106 100 96 93 99 92 96 91 94 89 87 102 95 91 87 94 87 92 86 90 85 83 98 91 86 83 90 82 88 82 87 81 79 94 87 82 78 86 78 85 78 83 77 75 91 83 78 75 82 75 81 74 80 74 72 87 80 75 71 79 71 78 71 77 71 69 84 76 72 68 76 68 75 68 74 68 67 81 74 69 66 73 66 72 65 72 65 64

Medium beam, 2500lm Engine, 119 lm/W at 21W

Candela Curve

500 1000 1500 2000

6RN / C6L25935MZ10U / C6RDLCL

Output lumens: Input watts: CRI: CCT 1: Spacing Crit.: Beam Angle:

2527 lms 21.3 W 90 min 3500K 0.96 56°

Zonal summary

Zone Lumens %Luminaire

0-30 0-40 0-60 0-90

1994 2410 2524 2527

78.9% 95.4% 99.9% 100.0%

Angle Mean CP Lumens

0 2954

5 2968

10 2965

283

15 2929

20 2620

811

25 2022

30

1240

900

35

628

40

322

416

45

137

50

15

110

55

4

60

2

4

65

1

70

1

1

75

0

80

0

0

85

0

90

0

0

Single unit data

Height to Initial center beam

Beam

lighted plane foot-candles diameter (ft)*

5′

118

4.8′

6′

82

5.8′

7′

60

6.7′

8′

46

7.7′

9′

36

8.6′

  • Beam diameter is where foot-candles drop to 50% of maximum.

Multiple unit data – RCR 2

Spacing Initial center beam

Watts

on center

foot-candles

per sq. ft.

5′

116.0

0.94

6′

76.0

0.62

7′

54.0

0.44

8′

45.0

0.37

9′

36.0

0.30

38′ x 38′ x 10′ Room, Workplane 2.5′ above floor, 80/50/20% Reflectances

Efficacy: 118.6 lm/W Report2: STMR-2437

Adjustment factors

Finish

CCT

CL = 100% CC = 95% CD = 87% CZ = 63% WH = 87% BK = 57%

90CRI, 4000K = 102% 90CRI, 3500K = 100% 90CRI, 3000K = 96% 90CRI, 2700K = 92%

Lumens
6000lm = 240% 4800lm = 192% 3500lm = 140% 3000lm = 120% 2500lm = 100% 2000lm = 80% 1500lm = 60% 1000lm = 40%

Coefficients of utilization

Ceiling

80%

70%

50%

30% 0%

Wall 70 50 30 10 50 10 50 10 50 10 0

RCR Zonal cavity method – Effective floor reflectance = 20%

Room Cavity Ratio

0 119 119 119 119 116 116 111 111 106 106 100 1 114 111 109 107 109 105 105 102 101 99 94 2 109 104 100 97 102 96 99 94 96 92 88 3 103 97 93 89 96 88 93 87 91 85 83 4 99 91 86 82 90 82 88 81 86 80 77 5 94 86 81 76 85 76 83 75 82 75 73 6 90 81 75 71 80 71 79 71 77 70 68 7 85 77 71 67 76 67 75 66 73 66 64 8 81 72 67 63 72 63 71 62 70 62 61 9 78 69 63 59 68 59 67 59 66 59 57 10 74 65 60 56 65 56 64 56 63 56 54

1. Correlated Color Temperature within specs as defined in ANSI_NEMA_ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products. 2. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products.

CalculiteLEDgen3_6in_Downlight_C6RDL 04/24 page 10 of 11

C6RDL Calculite LED 6″ gen 3
Round Downlight

Wide beam, 2500lm Engine, 112 lm/W at 21W

Candela Curve

300 600 900 1200

6RN / C6L25935WZ10U / C6RDLCL

Output lumens: Input watts: CRI: CCT 1: Spacing Crit.: Beam Angle:

2378 lms 21.3 W 90 min 3500K 1.3 76°

Zonal summary

Zone Lumens %Luminaire

0-30 0-40 0-60 0-90

1420 2131 2376 2378

59.7% 89.6% 99.9% 100.0%

Angle Mean CP Lumens

0

1616

5

1642

10

1705

159

15

1780

20

1762

501

25

1665

30

1478

760

35

1160

40

758

711

45

277

50

25

238

55

7

60

3

7

65

2

70

1

2

75

1

80

0

1

85

0

90

0

0

Single unit data

Height to Initial center beam

Beam

lighted plane foot-candles diameter (ft)*

5′

65

6.5′

6′

45

7.8′

7′

33

9.1′

8′

25

10.4′

9′

20

11.7′

  • Beam diameter is where foot-candles drop to 50% of maximum.

Multiple unit data – RCR 2

Spacing Initial center beam

Watts

on center

foot-candles

per sq. ft.

5′

107.0

0.94

6′

70.0

0.62

7′

50.0

0.44

8′

42.0

0.37

9′

34.0

0.30

38′ x 38′ x 10′ Room, Workplane 2.5′ above floor, 80/50/20% Reflectances

Efficacy: 111.6 lm/W Report2: STMR-2438

Adjustment factors

Finish

CCT

CL = 100% CC = 95% CD = 87% CZ = 63% WH = 87% BK = 57%

90CRI, 4000K = 102% 90CRI, 3500K = 100% 90CRI, 3000K = 96% 90CRI, 2700K = 92%

Lumens
6000lm = 240% 4800lm = 192% 3500lm = 140% 3000lm = 120% 2500lm = 100% 2000lm = 80% 1500lm = 60% 1000lm = 40%

Coefficients of utilization

Ceiling

80%

70%

50%

30% 0%

Wall 70 50 30 10 50 10 50 10 50 10 0

Room Cavity Ratio

RCR
0 1 2 3 4 5 6 7 8 9 10

Zonal cavity method – Effective floor reflectance = 20%
119 119 119 119 116 116 111 111 106 106 100 113 110 108 105 108 104 104 100 100 97 93 107 102 98 94 100 93 97 91 94 89 85 101 94 89 85 93 84 90 83 88 81 78 95 87 81 77 86 76 84 75 82 75 72 90 81 75 70 80 70 78 69 76 69 66 85 75 69 64 74 64 73 64 71 63 61 80 70 64 59 69 59 68 59 67 58 56 76 65 59 54 65 54 64 54 63 54 52 72 61 55 50 61 50 60 50 59 50 48 68 57 51 47 57 47 56 47 55 46 45

1. Correlated Color Temperature within specs as defined in ANSI_NEMA_ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products. 2. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products.

© 2024 Signify Holding. All rights reserved. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify.
CalculiteLEDgen3_6in_Downlight_C6RDL 04/24 page 11 of 11

Signify North America Corporation 400 Crossing Blvd, Suite 600 Bridgewater, NJ 08807 Telephone: 800-555-0050

Signify Canada Ltd. 281 Hillmount Road, Markham, ON, Canada L6C 2S3 Telephone: 800-668-9008

All trademarks are owned by Signify Holding or their respective owners. www.lightolier.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals