ACCURATE LOCK HARDWARE M8800ELR Motor Drive Electrified Latch Retraction Instruction Manual

June 1, 2024
ACCURATE LOCK HARDWARE

ACCURATE LOCK HARDWARE M8800ELR Motor Drive Electrified Latch Retraction

ACCURATE LOCK HARDWARE M8800ELR Motor Drive Electrified Latch
Retraction

INTRODUCTION

Outside trim (or both outside and inside trim depending on the lock function) is locked.
The main latch bolt is retracted when power is applied. The main latch bolt is extended in the event of a power failure.
Key Cylinder (by others) will override electronics to retract latch bolt.

ELECTRICAL SPECIFICATIONS

Filtered and Regulated Power Supply

Voltage: 24VDC (21VDC-30VDC)
Current: 625mA MAX Inrush, 150mA MAX Holding Non-polarized leads

Product Description

2 CONDUCTOR WIRE RUN

DISTANCE| WIRE GAUGE
125’| 22
200’| 20
350’| 18
500’| 16
800’| 14
1250’| 12

ONBOARD INDICATOR LIGHT ASSIGNMENTS

GREEN (POWER)| YELLOW (SENSOR)| RED (ERROR)| INDICATION| POSSIBLE SOLUTION
---|---|---|---|---
Off| Off| Off| No Power.| Connect the wiring between the power supply and the mortise lock.
On| On| Off| Normal Operation. The main latch bolt is retracted to the preset retracted position. The device is allowed 2 attempts.|
On| Off| On| Error in operation. The main latch bolt did not retract to the preset retracted position within 2 attempts.| Clear the jam condition manually.
On| On| On| Error in operation. Without power being removed, the main latch bolt unintentionally extended from the preset retracted position, and then the main latch bolt did not retract back to the preset retracted position within 2 attempts.| Clear the jam condition manually.
On| Blink| On| Error in operation. The main latch bolt did not extend from the preset retracted position when the power was last removed.
The device will not attempt a retraction.| Clear the jam condition manually.
On| Simultaneous Blink| Error in operation. The input voltage dropped below the specification during operation.| Decrease the wire run or increase the wire gauge.
On| Alternating Blink| Error in operation. An electronics fault was detected.| An electronics replacement is required.

Maintain input power to the mortise lock and check the onboard indicator lights. Remove input power before attempting a solution.