Specifications:
- Product: Mortise lock with Security Monitoring (SM2)
- Features: Independent monitoring of the deadlatch (AM) and locking bar (LB) positions
- Electrical Specifications :
- Two SPDT Mechanical Switches Mounted Inside the Lockset
- Voltage : 125 VAC, 30 VDC
- Current: 1 AMP (Black Wire), 0.5 AMP (Red Wire)
- Note: Mainly used as a dry contact monitoring switch
Product Usage Instructions
Wiring Diagram:
- AM Black Wire – Common Wire, Red Wire – Open Loop Secure, Violet Wire – Closed Loop Secure
- LB Brown Wire – Common Wire, Red Wire – Open Loop Secure, Green Wire – Closed Loop Secure
Installation:
- Ensure the power source is turned off before installation.
- Locate the appropriate wires based on the wiring diagram provided.
- Connect the black wire to the common wire, red wire to the open loop secure, and violet/green wire to the closed loop secure accordingly for AM and LB. Securely mount the lockset in place following manufacturer guidelines.
Operation:
- Once installed, test the functionality by moving the deadlatch and locking bar to check if the monitoring system responds correctly.
- Ensure all connections are secure and properly set up before regular use.
Maintenance:
Regularly check the wiring connections for any signs of wear or damage. Clean
the lockset periodically to ensure smooth operation.
SM2 – SECURITY MONITORING
Independent monitoring of the deadlatch (AM) and locking bar (LB) positions.
ELECTRICAL SPECIFICATIONS
Two SPDT Mechanical Switches Mounted Inside the Lockset
NOTE: Mainly used as a dry contact monitoring switch
1 Annie Pl, Stamford CT 06902 | 203.348.8865 | accuratelockandhardware.com
FAQ
Q: What is the purpose of the Security Monitoring feature in SM2?
A: The Security Monitoring feature independently monitors the deadlatch and
locking bar positions for enhanced security.
Q: Can the SM2 be used in both residential and commercial settings?
A: Yes, the SM2 is suitable for use in both residential and commercial
environments.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>