BEGA 85176 Bollard Light
Product Information
Specifications:
- Model: Pollerleuchte Bollard Balise
- Dimensions: 85 x 176 mm
- Weight: 400 g
- Power Consumption: 13.5 W
- Luminous Flux: 1000 lm
- Colour Temperature: 3000 K
- Colour Rendering Index (CRI): > 80
- Luminous Efficiency: 74.1 lm/W
Product Usage Instructions
-
Application:
The Pollerleuchte Bollard Balise is designed with single-sided light output and asymmetrical shielded light distribution. The light is directed downwards, ensuring the greatest degree of illuminance near the luminaire. -
Safety:
Installation and operation must adhere to national safety regulations. Only qualified electricians should perform installation and commissioning to prevent damage due to improper use or installation. -
Overvoltage Protection:
The luminaire’s electronic components are protected against overvoltage according to DIN EN 61547. For additional protection against transients, separate overvoltage protection components are recommended. -
Installation:
Handle LED light output carefully during installation to avoid direct contact. Ensure the base of the luminaire is not below the top edge of the mounting surface. Use the provided mounting materials to secure the luminaire to a foundation or anchorage unit.
FAQ:
-
Q: What should I do if I need to make modifications to the luminaire?
A: Any modifications should be carried out by a qualified professional, and the person responsible for these modifications will be considered the manufacturer. -
Q: How can I achieve optimal protection for the electronic components in the luminaire?
A: Use bounce-free switching contacts like an electronic relay (solid-state relay) for ideal protection. For specific recommendations, refer to BEGA 71
Application
- Bollard with single-sided light output and asymmetrical shielded light distribution.
- The light is directed downwards and is completely shielded above the horizontal. The greatest degree of illuminance is generated near the luminaire.
Dark Sky
The light of this luminaire is directed evenly and highly efficiently onto the
surface to be illuminated. No light is emitted into the upper half-space of
the luminaire.
Product Description
- Luminaire made of aluminium alloy, aluminium and stainless steel
- BEGA Unidure® coating technology
- Clear safety glass
- The reflector surface is made of pure aluminium Silicone gasket
- Luminaire with mounting plate for bolting onto a foundation or an anchorage unit
- Mounting plate with 2 elongated holes
- Width 9 mm · Spacing 220 mm
- Mounting bracket with connection box for through-wiring of up to 5×2,5@
- BEGA Ultimate Driver®
- Complies with flicker requirements by IEEE 1789,
- DIN IEC/TR 63158, DIN IEC/TR 61547-1
- LED power supply unit 220-240 V x 0/50-60 Hz
- DC 176-264 V
- DALI-controllable
- Number of DALI addresses: 1
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets
- – Conformity mark
- This product contains light sources of energy efficiency class(es) C
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage by DIN EN 61547.
- To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
- The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.
Installation
LEDs are high-quality electronic components!
- Please avoid touching the light output opening of the LED directly during installation or relamping.
- The base of the luminaire must not be below top edge of the mounting surface.
- A cable length of about 300 mm above the mounting surface is sufficient for the electrical connection of the luminaire.
- The connection box allows through-wiring of the luminaire.
- Remove the mounting plate in the base of the luminaire by undoing the screws.
- Using the provided mounting materials or other suitable mounting materials, screw-fit the mounting plate to a foundation or anchorage unit 71 890.
- Open the connection box.
- Lead the main supply cable into the connection box. Make earth conductor connection and electrical connection.
- Lead the luminaire connecting cable through the compression nipple into the connection box. Make earth conductor connection and electrical connection.
- Observe the correct configuration of the connecting cable. Connect the earth conductor to the green-yellow wire (PE), the live conductor to the brown wire (L) and the neutral conductor to the blue wire (N).
- The connection of the control cables is achieved using both leads marked with DALI.
- In case these leads are not used the luminaire will be operated at full light output.
- Close the connection box.
- Place the luminaire onto the mounting plate, adjust and fix it.
Dimension
Cleaning And Maintenance
- Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
- Do not use high-pressure cleaners.
Lamp
- Module connected wattage 12 W
- Luminaire connected wattage 13.5 W
- Rated temperature ta = 25 °C
- Service life criteria 50 000 h / L70
85 176 K3
- Module designation LED-1607/830
- Colour temperature 3000 K
- Colour rendering index CRI > 80
- Module luminous flux 2095 lm
- Luminaire luminous flux * 1000 lm
- Luminaire luminous efficiency * 74,1 lm / W
85 176 K4
- Module designation LED-1607/840
- Colour temperature 4000 K
- Colour rendering index CRI > 80
- Module luminous flux 2125 lm
- Luminaire luminous flux * 1014 lm
- Luminaire luminous efficiency * 75,1 lm / W
-
- preliminary data
-
Please note:
- Do not remove the desiccant bag from the luminaire housing.
- It is needed to remove residual moisture.
Replacing the LED module
- The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
- The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire.
- Please follow the installation instructions for the LED module.
- Inspect and, if necessary, replace the luminaire gaskets.
- The defective glass must be replaced.
- Close the luminaire.
Accessories
- 71 890 Anchorage unit
- Anchorage unit with a mounting flange made of galvanised steel. Total length 400 mm.
- 2 stainless steel fixing screws M 8.
- 220 mm spacing
For the accessories, separate instructions for use can be provided upon request.
Spares Parts
- LED power supply unit DEV-0485/700i
- LED module 3000 K LED-1607/830
- LED module 4000 K LED-1607/840
- Reflector 76 002 158
- Gasket 83 001 518
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com.