BEGA 84 925 Compact Floodlight Instruction Manual

June 1, 2024
BEGA

BEGA 84 925 Compact Floodlight

Specifications

  • Product Name: Kompaktscheinwerfer Compact floodlight Projecteur compact.
  • Material: Aluminium alloy DALI-controllable with 1 DALI address Basic insulation provided.
  • Safety class: I
  • Protection class: IP 65 (Dust-tight and protection against water jets).
  • Impact strength: IK07.
  • Lamp Module Connected Wattage: 37.5 W.
  • Luminaire Connected Wattage: 40.5 W.
  • Colour Temperature: 3000 K (LED-0779/930).
  • Colour Rendering Index (CRI): >90.
  • Module Luminous Flux: 4855 lm.
  • Luminaire Luminous Flux : 2712 lm.
  • Luminaire Luminous Efficiency: 67 lm/W.

DIMENSION

BEGA-84-925-Compact-Floodlight-FIG-1

Instructions for use

Application

  • Compact floodlights with G½ connecting thread.
  • The floodlight can be screwed on by the customer with any G½ female thread according to ISO 228 or with BEGA accessories.

Product description

  • Luminaire made of aluminium alloy, aluminium and stainless steel.
  • BEGA Unidure® coating technology.
  • Colour graphite or silver.
  • BEGA Hybrid Optics®.
  • Clear safety glass.
  • Reflector surface made of pure aluminium Rotation range of floodlight 350°.
  • Swivel range -20°/+90°.
  • Mounting bracket with G½ threaded connection.
  • Thread length: 11 mm.
  • Connecting cable X05BQ-F 5 G 1 mm².
  • Cable length 1 m.
  • BEGA Ultimate Driver®.
  • Complies with flicker requirements under IEEE 1789,.
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1.
  • LED power supply unit 220-240 V x 0/50-60 Hz.
  • DC 176-264 V.
  • DALI-controllable.
  • Number of DALI addresses: 1.
  • Basic insulation is provided between the mains and control cables.
  • BEGA Thermal Control®.
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire.
  • Safety class I.
  • Protection class IP 65.
  • Dust-tight and protection against water jets Impact strength IK07.
  • Protection against mechanical impacts < 2 joule.
  • Safety mark.
  • Conformity mark.
  • Wind catching area: 0.027 m².
  • Weight: 2.4 kg.
  • This product contains light sources of energy efficiency class(es) E.

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage under DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at: www.bega.com.
  • The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.

Lamp

  • Module connected wattage 37.5 W
  • Luminaire connected wattage 40.5 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 35 °C

84 925 K3

  • Module designation LED-0779/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 4855 lm
  • Luminaire luminous flux 2712 lm
  • Luminaire luminous efficiency 67 lm / W

84 925 K4

  • Module designation LED-0779/940
  • Colour temperature 4000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 4930 lm
  • Luminaire luminous flux 2754 lm
  • Luminaire luminous efficiency 68 lm / W

Lighting technology

  • Focused light distribution with minimal diffuse light percentage.
  • Half beam angle 10°
  • For special lighting applications, an optical filter can be used to change the symmetrical light cone into a flat beam light distribution

Installation

  • Screw the floodlight G½ threaded connection firmly into the on-site G½ female thread or BEGA accessory.
  • G½ threaded connection torque = 40 Nm.
  • Secure the screw connection from loosening on site (if provided with locking screw S, see fig. A).
  • Check the earth conductor connection between the G½ threaded connection and the on-site G½ female thread.

BEGA-84-925-Compact-Floodlight-FIG-2

Adjust floodlight:
Undo the hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 30 mm) and set the desired beam direction.

Torque:

  • Hexagon socket screw = 7 Nm
  • Hexagon nut = 35 Nm
    Secure bolted connection Gß against loosening by tightening the hexagon socket screw (wrench size 2 mm) (see sketch B, C).

The electrical connection must be carried out with matching protection class and safety class, strain-relieved, with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.

  • Note the correct configuration of the main supply cable.
  • Make mains supply connection at the brown (L), blue (N) and green-yellow lead (1).
  • The connection of the control cables is achieved using both leads marked with DALI.
  • In case these leads are not used the luminaire will be operated at full light output

Maintenance

Cleaning · Maintenance

  • Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high-pressure cleaners.

Replacing the LED module

  • The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
  • Disconnect the system from the power supply.
  • Open the floodlight:
  • Loosen the back locking pin (hexagon socket wrench size 2 mm) in the trim ring.
  • Remove the trim ring along with the safety glass and reflector by twisting it anti-clockwise.
  • Replace the LED module.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • The defective glass must be replaced.
  • Place the trim ring with glass and reflector on the floodlight housing so that the notches in the trim ring and luminaire housing sit on top of each other.
  • Twist on the trim ring clockwise as far as the stop. Screw in the locking pin.

Accessories

  • 71 281 Shield
  • 71 287 Cylindrical shield
  • 71 291 Optical filter flat beam
  • 71 042 Adapter for installation on a pole
  • 70 204 Earth spike
  • 70 214 Pole cap for pole ø 48 mm
  • 70 248 Pole cap for pole ø 60 mm
  • 70 245 Mounting box
  • 70 252 General fastener
  • 70 280 Tube clamp G½
  • 70 283 Screw clamp
  • 70 379 Crossbeam G½
  • 70 889 Tension belt

For the accessories, separate instructions for use can be provided upon request.

Spares

  • Trim ring graphite with glass 25 000 228
  • Trim ring silver with glass 25 000 229
  • LED power supply unit DEV-0270/1050i
  • LED module 3000 K LED-0779/930
  • LED module 4000 K LED-0779/940
  • Reflector 75 005 100
  • Gasket housing 83 001 027
  • Gasket trim ring 83 002 223

MORE INFORMATION

FAQ

Frequently Asked Questions

  • Q: Can I install the luminaire myself?
    • A: Installation and commissioning should only be done by a qualified electrician to ensure safety and proper functioning.
  • Q: What should I do for additional protection against overvoltage?
    • A: Consider using separate overvoltage protection components recommended by the manufacturer available on their website.
  • Q: How can I achieve optimal protection for the electronic components?
    • A: Use bounce-free switching contacts like an electronic relay for ideal protection.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals