BEGA 84 929 Compact Floodlight Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
50.22 Technical amendments reserved
84 929
Compact floodlight
84 929 Compact Floodlight
Instructions for use
Application
Compact floodlights with G½ connecting thread.
The floodlight can be screwed on by the customer with any G½ female thread
according to ISO 228 or with BEGA accessories.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Colour graphite or silver
BEGA Hybrid Optics®
Clear safety glass
Reflector surface made of pure aluminium
Rotation range of floodlight 350°
Swivel range -20°/+90°
Mounting bracket with G½ threaded connection
Thread length: 11 mm
Connecting cable X05BQ-F 5 G 1 mm²
Cable length 1 m
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-276 V
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK06
Protection against mechanical impacts < 1 joule
– Safety
mark
****– Conformity mark
Wind catching area: 0.017 m²
Weight: 1.3 kg
This product contains light sources of energy efficiency class(es) E
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Installation
Screw the floodlight G½ threaded connection firmly into the on-site G½ female
thread or BEGA accessory.
G½ threaded connection torque = 40 Nm.
Secure the screw connection from loosening on site (if provided with locking
screw S, see fig. A).
Check the earth conductor connection between the G½ threaded connection and
the on-site G½ female thread.
Adjust floodlight:
Undo hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 30
mm) and set the desired beam direction.
Torque:
Hexagon socket screw = 7 Nm
Hexagon nut = 35 Nm
Secure bolted connection G½ against loosening by tightening the hexagon socket
screw (wrench size 2 mm) (see sketch B, C).
The electrical connection must be carried out with matching protection class
and safety class, strain-relieved, with suitable connection terminals (not
included in the scope of delivery) at the luminaire power supply cable.
Note correct configuration of the mains supply cable.
Make mains supply connection at the brown (L), blue (N) and green-yellow lead
( ).
The connection of the control cables is achieved by means of the both leads
marked with DALI.
In case these leads are not used the luminaire will be operated at full light
output.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Lamp
Module connected wattage | 10.2 W |
---|---|
Luminaire connected wattage | 11.8 W |
Rated temperature | ta= 25 °C |
Ambient temperature | ta max = 55 °C |
84 929 K3
Module designation | LED-1148/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 1500 lm |
Luminaire luminous flux | 1098 lm |
Luminaire luminous efficiency | 93,1 lm / W |
84 929 K4
Module designation | LED-1148/940 |
---|---|
Colour temperature | 4000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 1575 lm |
Luminaire luminous flux | 1153 lm |
Luminaire luminous efficiency | 97,7 lm / W |
Lighting technology
Wide beam light distribution
Half beam angle 20°
For special lighting applications, an optical filter can be used to change the
symmetrical light cone into a flat beam light distribution.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The replacement can be carried out by
a qualified person using standard tools.
Disconnect the system from the power supply.
Open the floodlight:
Remove the trim ring along with the safety glass and reflector by twisting it
anti-clockwise.
Replace LED module.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place the trim ring with glass and reflector on the floodlight housing so that
the notches in the trim ring and luminaire housing sit on top of each other.
Twist on the trim ring clockwise as far as the stop.
Accessories
71 279 | Shield |
---|---|
71 284 | Cylindrical shield |
71 289 | Optical filter flat beam |
71 042 | Adapter for installation on a pole |
70 204 | Earth spike |
70 214 | Pole cap for pole ø 48 mm |
70 248 | Pole cap for pole ø 60 mm |
70 245 | Mounting box |
70 252 | General fastener |
70 280 | Tube clamp G½ |
70 283 | Screw clamp |
70 379 | Cross beam G½ |
70 889 | Tension belt |
For the accessories a separate instructions for use can be provided upon request.
Spares
Trim ring graphite with glass | 25 000 246 |
---|---|
Trim ring silver with glass | 25 000 247 |
LED power supply unit | DEV-0475/300 |
LED module 3000 K | LED-1148/930 |
LED module 4000 K | LED-1148/940 |
Reflector | 75 005 130 |
Gasket trim ring | 83 002 169 |
Gasket housing | 83 002 171 |
BEGA Gantenbrink-Leuchten KG
· Postfach 31 60
· 58689 Menden
· info@bega.com
· www.bega.com
References