Application
Compact floodlight for installation on BEGA profile poles with profile groove.

Product description

Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure® coating technology Colour graphite or silver BEGA Hybrid Optics® Clear safety glass
Reflector surface made of pure aluminium Rotation range of floodlight 350°
Swivel range -15°/+130°
Connecting cable X05BQ-F 5 G 1 mm²
Cable length 1 m
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz DC 176-264 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK07
Protection against mechanical
impacts < 2 joule
– Conformity mark
This product contains light sources of energy efficiency class(es) E

Light technique
Broad spread light distribution.
Half beam angle 45°
For special lighting applications, an optical filter can be used to change the symmetrical light cone into a flat beam light distribution.

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.

BEGA 85 122 Compact Floodlight - Fig 1

Installation

Loosen the hexagon socket screws (wrench size 5 mm) at the pole head and lift out the connection box (see sketch 1, 2).
Insert the floodlight into the profile groove on the profile pole and fix it in the desired position using both hexagon socket screws (wrench size 4 mm) (see sketch 3).
Route the connecting cable for the floodlight into the pole through the closest slotted hole in the profile groove (see sketch 4).
The electrical connection is made in the connection box in the pole head.
Guide the floodlight connecting cable through the cable gland into the connection box.
Tighten the screw cable gland.

Make the earth conductor connection and the electrical connection.
Note correct configuration of the mains supply cable. The earth conductor is connected at the green-yellow ****, the phase to the brown (L), and the neutral conductor to the blue (N) marked wire.
The connection of the control cables is achieved by means of the both leads marked with DALI. In case these leads are not used the luminaire will be operated at full light output.
Place the connection box on the profile pole and secure it in place.
Make sure that gasket is positioned correctly.
Tighten the screws uniformly in crosswise fashion.
Adjust floodlight:
Undo hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 27 mm) and set the desired beam direction (see sketch 5, 6).
Torque:
Hexagon socket screw = 7 Nm
Hexagon nut = 35 Nm
Secure bolted connection Gß against loosening by tightening the hexagon socket screws (wrench size 2 mm).

Lamp

Module connected wattage 24.1 W
Luminaire connected wattage 26.8 W
Rated temperature ta = 25 °C
Ambient temperature ta max= 45 °C

85 122 K3

Module designation LED-0800/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 3350 lm
Luminaire luminous flux 2472 lm
Luminaire luminous efficiency 92,2 lm / W

85 122 K4

Module designation LED-0800/940
Colour temperature 4000 K
Colour rendering index CRI > 90
Module luminous flux 3400 lm
Luminaire luminous flux 2509 lm
Luminaire luminous efficiency 93,6 lm / W

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
Disconnect the system from the power supply. Open the floodlight:
Loosen the back locking pin (hexagon socket wrench size 2 mm) in the trim ring.
Remove the trim ring along with the safety glass and reflector by twisting it anti-clockwise.
Replace LED module.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place the trim ring with glass and reflector on the floodlight housing so that the notches in the trim ring and luminaire housing sit on top of each other.
Twist on the trim ring clockwise as far as the stop. Screw in the locking pin.

Accessories

71 280
71 285
71 290| Shield
Cylindrical shield
Optical filter flat beam
---|---

For this luminaire we recommend the followingBEGA luminaire poles:

Profile poles made of lacquered aluminium

84 700 square
84 701 square
84 702 round
84 703 round| H 4000 mm
H 6000 mm
H 4000 mm
H 6000 mm
---|---

Profile poles with glued laminated wood in accordance with DIN EN 14 080

84 696 square
84 697 square
84 698 round
84 703 round| H 4000 mm
H 6000 mm
H 4000 mm
H 6000 mm
---|---

For the accessories a separate instructions for use can be provided upon request.

Spares
Trim ring graphite wih glass 25 000 234
Trim ring silver with glass 25 000 235
LED power supply unit DEV-0353/700
LED module 3000 K LED-0800/930
LED module 4000 K LED-0800/940
Gasket housing 83 002 022
Gasket trim ring 83 002 222

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals