BEGA 84258K3 Surface Floodlight Instruction Manual

June 1, 2024
BEGA

BEGA 84258K3 Surface Floodlight

BEGA-84258K3-Surface-Floodlight-PRO

Product Information

Specifications

  • Product: Surface floodlight with mounting box and outrigger arm
  • Light Distribution: Asymmetrical
  • Application: Ceilings and walls
  • Usage: Illuminating wall, ceiling, ground surfaces, or advertising boards
  • Lamp Module Connected Wattage: 11.3 W
  • Luminaire Connected Wattage: 13 W
  • Colour Temperature: 3000 K and 4000 K
  • Colour Rendering Index (CRI): > 90
  • Luminous Flux: 1770 lm – 1840 lm
  • Luminous Efficiency: 102.5 lm/W – 107.1 lm/W

Installation Instructions

  1. Undo the screw at the wall box and remove the mounting plate.
  2. Pass the power connecting cable through the cable entry in the mounting plate.
  3. Note the position of the application of the mounting plate arrow down.
  4. Fix the mounting plate onto the mounting surface using suitable fixing material and gasket rings.
  5. Make the earth conductor connection and the electrical connection.
  6. Create an earth conductor connection between the luminaire and the mounting plate.
  7. Place the surface floodlight onto the mounting plate and fix it with screws.
  8. To adjust the surface floodlight, undo joint screws, adjust position, and then tighten joint screws with a torque of 14 Nm.

Note: Do not remove the desiccant bag from the luminaire housing as it is needed to remove residual moisture.

FAQ

  • Q: Can I install the surface floodlight on any surface?
    A: The surface floodlight is designed for installation on ceilings and walls. Ensure proper mounting for optimal performance.

  • Q: What is the importance of the desiccant bag in the luminaire housing?
    A: The desiccant bag helps in removing residual moisture from the luminaire housing, ensuring longevity and performance.

  • Q: How do I adjust the position of the surface floodlight?
    A: To adjust the position, simply undo the joint screws, reposition the floodlight, and then tighten the screws to secure the new position.

Application

Surface floodlight with mounting box and outrigger arm for installation on ceilings and walls. With asymmetrical light distribution for illuminating wall-, ceiling-, ground surfaces or advertising boards.

Product description

  • Luminaire made of aluminium alloy, aluminium and stainless steel

  • BEGA Unidure® coating technology

  • Colour graphite or silver

  • Safety glass

  • Reflector made of pure anodised aluminium

  • Rotation range surface floodlight 350°

  • Swivel range of outrigger arm:

    • Joint mounting box 0°-180° in steps of 22,5°
    • Joint surface floodlight: -60°/+120° infinitely
  • Mounting plate with 3 fixing holes ø 5.3 mm

  • Angle 120° · Pitch circle ø 52 mm 1 cable entry for mains supply cable up to ø 10,5 mm

  • Connection terminal 2.5@

  • Earth conductor connection Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR 63158, DIN IEC/TR 61547-1

  • LED power supply unit

  • 220-240 V 0/50-60 Hz DC 176-276 V

  • BEGA Thermal Control®
    Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire

  • Safety class I

  • Protection class IP 65

  • Dust-tight and protection against water jets

  • Impact strength IK07

  • Protection against mechanical impacts < 2 joule

  • – Safety mark

  • – Conformity mark

  • Weight: 2.0 kg

  • This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 11.3 W
  • Luminaire connected wattage 13 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 50 °C

84 258 K3

  • Module designation LED-0590/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1770 lm
  • Luminaire luminous flux 1332 lm
  • Luminaire luminous efficiency 102,5 lm / W

84 258 K4

  • Module designation LED -0590/940
  • Colour temperature 4000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1840 lm
  • Luminaire luminous flux 1392 lm
  • Luminaire luminous efficiency 107,1 lm / W

Installation

  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Undo screw at wall box and remove mounting plate.
  • Pass the power connecting cable through the cable entry in the mounting plate.
  • Note position of application of the mounting plate “arrow down”.
  • Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
  • Be sure to use the gasket rings supplied.
  • Make the earth conductor connection and the electrical connection.
  • Make earth conductor connection between luminaire and mounting plate.
  • Place the surface floodlight onto the mounting plate and fix with screw.
  • To adjust the surface floodlight undo joint screws. Adjust surface floodlight position.
    Tighten joint screws.
    Torque = 14 Nm

DIMENSION

BEGA-84258K3-Surface-Floodlight-1

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners.

Please note:

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.
  • The connecting cable between mounting box and floodlight has to be inspected regarding obvious damages and has to be replaced by a qualified electrician only.

Spares

  • LED power supply unit DEV-0475/500
  • LED module 3000 K LED-0590/930
  • LED module 4000 K LED-0590/940
  • Reflector 76 001 876
  • Gasket Montagedose 83 001 840
  • Gasket housing 83 001 899

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden
info@bega.com
www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals