USER MANUAL
Light building element head
OVERVIEW
Instructions for use
Application
Light building element head with shielded light for illuminating and designing squares, driveways and entrance areas.
Light exit 360°. The light is deflected by means of a conical reflector onto the surface to be illuminated.
With an upward facing interface for the installation of light management
components in accordance with Zhaga Book 18 Ed. 3.0 (Z-LEX-R), suitable for
components
Zhaga Book 18 Ed. 3.0 (Z-LEX-M), e.g. Zhaga Air Connector 71 210)
A light building element tube is required for the installation of the light building element head, which must be ordered separately (see accessories).
Product description
Luminaire made of cast aluminium, aluminium and stainless steel
BEGA Unidure® coating technology
Clear synthetic cover with optical structure
Silicone gasket
Reflector surface made of pure aluminium
Connecting cable H05VV-F 3 G 1@
Cable length 4 m 1 built-in interface according to Zhaga Book 18 Ed. 3.0
(Z-LEX-R) with closing cap in the luminaire head
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit 220-240 V x 0/50-60 Hz DC 176-280 V
During DC operation the LED power is reduced to 15 %
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets Impact strength IK04
Protection against mechanical impacts < 0.5 joule c – Conformity mark
Horizontal wind catching area: 0.043 m²
Weight: 5.6 kg
This product contains light sources of energy efficiency class(es) C, D
Dark Sky
The light of this luminaire is directed evenly and highly efficiently onto the surface to be illuminated. No light is emitted into the upper half-space of the luminaire.
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.
Installation
When selecting a light management component, ensure that it is suitable for
use in the upward-facing Zhaga fitting.
For the installation of light management components according to Zhaga Book
18, remove the factor-installed closing cap from the luminaire housing by
twisting it anti-clockwise.
Insert the light management components into the socket and turn them clockwise
until they stop.
Please observe the manufacturer’s opearting instructions and data sheets.
The luminaire may only be operated with inserted Zhaga components or closing
caps.
Thread the connection cable into the light building element tube. Align the
light building element head and secure it in place.
Tighten the lateral hexagon socket screws (wrench size 5 mm).
Torque = 16 Nm
Open the connection box.
Lead the luminaire wiring and mains supply cable through the cable entry into
the connection box.
Note correct configuration of the mains supply cable. Make mains supply
connection at the brown (L), blue (N) and green-yellow lead (1).
Close the connection box.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Lamp
Module connected wattage 28 W
Luminaire connected wattage 32.2 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 60 °C
85 030 K3
Module designation 4x LED-1313/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 4640 lm
Luminaire luminous flux 3451 lm
Luminaire luminous efficiency 107,2 lm / W
85 030 K4
Module designation 4x LED-1313/840
Colour temperature 4000 K
Colour rendering index CRI > 80
Module luminous flux 4860 lm
Luminaire luminous flux 3615 lm
Luminaire luminous efficiency 112,3 lm / W
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective synthetic diffuser must be replaced.
Close the luminaire.
Accessories
The light building element head can be combined with the following light
building element tubes:
Cylindrical aluminium light building element tube, lacquered, complete with
door and connection box 71 084
84 712 with anchorage unit H 3900 mm
84 713 with base plate H 3900 mm
Cylindrical aluminium light building element tube, lacquered, with door, connection box 71 084 and integrated adjustable floodlight
84 714 with anchorage unit H 3900 mm
84 715 with base plate H 3900 mm
Cylindrical aluminium light building element tube, lacquered, with door, connection box 71 084 and 2 integrated adjustable floodlights
84 716 with anchorage unit H 3900 mm
84 717 with base plate H 3900 mm
Cylindrical laminated wood and aluminium light building element tube, with door and connection box 71 084
84 718 with anchorage unit H 3900 mm
84 719 with base plate H 3900 mm
70 899 Anchorage unit for light building element tube with base plate
For the accessories a separate instructions for use can be provided upon request.
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
Specifications:
- Lamp Module connected wattage: 28 W
- Luminaire connected wattage: 32.2 W
- Rated temperature: 25°C – 60°C
- Ambient temperature: 85°C
FAQ
Can I remove the desiccant bag from the luminaire housing?
No, do not remove the desiccant bag as it is necessary for removing residual moisture from the luminaire housing.